Scope

GB/T 7964-2020 is the English-translated version of 烧结金属材料(不包括硬质合金) 室温拉伸试验.

GB/T 7964-2020 is the Chinese standard "Sintered Metal Materials (Excluding Hardmetal) - Tension Testing at Room Temperature".

Its scope clause reads: This Standard specifies the room temperature tensile test method for sintered metal materials, including principles, symbols and instructions, specimens, test device, test procedures, calculation of test results, numerical rounding-off and test reports.

This Standard is applicable to the determination of the yield strength, specified plastic elongation strength, tensile strength, elongation after break, and reduction of area for machined or non-machined sintered metal materials (excluding hardmetal).

Its clauses include principle; symbols and instructions; specimen; test device; test procedures; calculation of test results; numerical rounding-off; test report.

It was issued by the State Administration for Market Regulation on MARCH 06, 2006 and took effect on FEBRUARY 01, 2021.

Found what you need?

Document preview — GB/T 7964-2020

National Standard of the People's Republic of China

ICS
77.160
Classification
H 22
Replacing
GB/T 7964-1987

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope5
  • 2 Normative References5
  • 3 Principle5
  • 4 Symbols and Instructions6
  • 5 Specimen7
  • 6 Test Device7
  • 7 Test Procedures7
  • 8 Calculation of Test Results8
  • 9 Numerical Rounding-off10
  • 10 Test Report11
  • Appendix A (Informative) Comparison List between Old and New Symbols12

Foreword

This Standard was drafted as per the rules specified in GB/T 1.1-2009.

This Standard replaced GB/T 7964-1987 Sintered Metal Materials (Excluding Hardmetal) -Tension Testing at Room Temperature.

Compared with GB/T 7964-1987, this Standard made the major technical changes as follows besides the editorial modifications:

--- Change "yield point" into "yield strength"; change "yield stress" into "specified plastic elongation strength"; and change "elongation" into "elongation after break" (see Clause 1 of this Edition; Clause 1 of 1987 Edition);

--- Add normative references (see Clause 2 of this Edition);

--- Modify "record the corresponding load, deformation or draw the stress-strain diagram (load-elongation diagram), measure mechanical properties" into "record the corresponding load and deformation by the computer to obtain the load-elongation diagram, and calculate the mechanical properties" (see Clause 3 of this Edition; Clause 2 of 1987 Edition);

--- Modify the expressions and corresponding instructions of the used symbols (see Clause 4 of this Edition; Chapter 1 of 1987 Edition);

--- Modify "performed in accordance with GB/T 7963-1987 Sintered Metal Materials (Excluding Hardmetal) - Tensile Test Pieces" into "sample preparation and requirements shall be performed in accordance with the provisions of GB/T 7963" (see Clause 5 of this Edition; Clause 3 of 1987 Edition);

--- Modify the part of the testing machine into "the testing machine of any system used for tensile testing, the accuracy should be Level-1 or better, and be tested according to GB/T 16825.1" (see 6.1 of this Edition; 4.1 of 1987 Edition);

---Confirm that the accuracy requirement of the extensometer is Level-1 or better (see 6.3 of this Edition; 4.3 of 1987 Edition);

--- Modify the "accuracy 0.02mm" of the size measuring instrument into "accuracy 0.01mm" (see 6.4 of this Edition; 4.4 of 1987 Edition);

--- Modify "measurement accuracy 0.02mm" into "measurement accuracy 0.01mm" (see 7.1.1 of this Edition; 5.1.1 of 1987 Edition);

--- Modify the rate control mode (see 7.2 of this Edition; 5.2 of 1987 Edition); Sintered Metal Materials (Excluding Hardmetal)

1 Scope

This Standard specifies the room temperature tensile test method for sintered metal materials, including principles, symbols and instructions, specimens, test device, test procedures, calculation of test results, numerical rounding-off and test reports.

This Standard is applicable to the determination of the yield strength, specified plastic elongation strength, tensile strength, elongation after break, and reduction of area for machined or non-machined sintered metal materials (excluding hardmetal).

2 Normative References

The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this document.

GB/T 7963 Sintered Metal Materials, Excluding Hardmetals - Tensile Test Pieces

GB/T 16825.1 Verification of Static Uniaxial Testing Machines - Part 1:

Tension/Compression Testing Machines - Verification and Calibration of the Force- Measuring System

3 Principle

Put the specimen in the appropriate position of the fixture; start the testing machine; make the specimen continuously and uniformly bear the tensile stress till break under the specified tensile speed; and record the corresponding load and deformation by the computer to obtain the load-elongation diagram; and calculate the mechanical properties.

5 Specimen

The preparation and requirements of the specimens shall be carried out in accordance with the provisions of GB/T 7963.

6 Test Device

6.1 Testing machine

The testing machine of any system used for tensile testing shall have an accuracy of Level-1 or better; and shall be tested in accordance with GB/T 16825.1. The testing machine shall have sufficient rigidity and shall not cause instability within its tensile load range.

6.2 Fixture

Choose a suitable specimen clamping device. The wedge chuck and collar chuck are usually used to transfer the load applied by the testing machine to the specimen. The axis of the specimen shall coincide with the center of the chuck of the testing machine.

6.3 Extensometer

The accuracy of the extensometer shall be Level-1 or better.

6.4 Size measuring instrument

Use a suitable instrument for measuring the specimen size, with an accuracy of 0.01 mm.

7 Test Procedures

7.1 Measuring specimen size

7.1.1 Cross-sectional area of the specimen

Respectively measure once in two directions perpendicular to the two ends and middle of the specimen gauge length, the measuring accuracy is 0.01mm. Choose the smallest of the three cross-sectional areas. The cross-sectional area is calculated according to Formulas (1) and (2).

a) Flat specimen:

b) Cylindrical specimen: […]

7.1.2 Specimen gauge length

The original specimen has a gauge length of 25.0mm and a marking accuracy of ±0.1mm.

7.2 Test speed

According to the characteristics of the testing machine, the specimen material and the purpose of the test, unless otherwise specified in the relevant material standards or agreements, the tensile test speed shall meet the following requirements:

--- When measuring the tensile yield strength, the strain rate shall not exceed 0.0008s-1;

--- When measuring the tensile strength, the strain rate shall not exceed 0.0024s-1.

NOTE: For the beam displacement control testing machine, it is allowed to set a speed equivalent to the above required strain rate. When using beam displacement control, the test rate is calculated as per the following formula: […]

8 Calculation of Test Results

8.1 Yield strength

Graphic method: on the tensile curve (Figure 1), find the constant load at the platform [Figure 1a)], or the lowest load at yield [Figure 1b)], or the load that begins to deviate from the straight line [Figure 1c)]. The yield strength is calculated according to Formula (3): […]

8.2 Specified plastic elongation strength Graphic method

When the specified plastic elongation strength is measured on the tensile curve (Figure 2), in the load-elongation diagram, OM (L0×epsilon p) is equal to the specified plastic deformation value; MN is parallel to OA and intersects the curve at p; the corresponding Fp is the specified plastic elongation force. The specified plastic […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 7964

EditionTitleRevisionStatus
GB/T 7964-2020Sintered metal materials( excluding hardmetal )—Tension testing at room temperaturecurrent editionCurrent
GB/T 7964-1987Sintered metal materials( excluding hardmetal )—Tension testing at room temperatureprevious editionSuperseded

This page sells the current edition, GB/T 7964-2020. Earlier editions are listed for reference only.

How to Download GB/T 7964-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 7964-2020

$125.00