Scope
GB/T 40289-2021 is the English-translated version of 光伏发电站功率控制系统技术要求.
GB/T 40289-2021 sets the technical requirements for the power control system of a photovoltaic power station, the system that adjusts the inverters, any energy storage and the reactive power compensation devices so that the station's active and reactive power, grid-connection point voltage and power factor follow the dispatch commands or preset values.
It covers the function and structure of the system, data collection and communication, start-stop control, active power control - including limit, constant value and difference control - reactive voltage control, locking, control process records, performance indicators and system inspection.
It applies to stations connected to the grid at 35 kV and above, and to stations connected to the public grid at 10 kV. It was issued on 21 May 2021 and has applied since 1 December 2021.
Found what you need?
Document preview — GB/T 40289-2021
National Standard of the People's Republic of China
- ICS
- 27.160
- Classification
- F 12
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 General requirements
- 5 Control system function and structure
- 6 Data collection and communication
- 7 Start-stop control
- 8 Active power control
- 9 Reactive voltage control
- 10 Locking
- 11 Control process record
- 12 System performance indicators
- 13 System Inspection
- Appendix A (informative) Photovoltaic power station power control mode
- Appendix B (informative) Power control system structure of photovoltaic power station
- Appendix C (Informative) Calculation Method of Theoretical Power Generation of Photovoltaic Power Station
Foreword
This document is in accordance with GB/T 1.1-2020 "Guidelines for Standardization Part 1: Structure and Drafting Rules of Standardization Documents". To be drafted.
1 Scope
This document specifies the function and structure of the power control system of photovoltaic power plants, data acquisition and communication, start-stop control, active power control, Technical requirements for reactive voltage control, blocking, control process recording, performance indicators and system testing.
This document applies to photovoltaics that are connected to the grid through a voltage level of 35kV and above, and connected to the public grid through a voltage level of 10kV. Power station.
2 Normative references
The contents of the following documents constitute the indispensable clauses of this document through normative references in the text. Among them, dated quotations Only the version corresponding to that date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to this document.
GB/T 19964 Technical Regulations for Connecting Photovoltaic Power Stations to Power Systems
GB/T 29321 Technical Specification for Reactive Power Compensation of Photovoltaic Power Station
GB/T 31366 Technical requirements for photovoltaic power station monitoring system
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 Photovoltaic power station power control system
By adjusting the power output of grid-connected inverters, energy storage equipment (if the power station is equipped with energy storage equipment), and reactive power compensation devices in the power station, the photovoltaic The power station's active power, reactive power, grid-connected point voltage, and power factor meet the command value or pre-set value requirements issued by the grid dispatching agency.
3.2 Rated power of photovoltaic power station
The sum of the rated power of all inverters in the photovoltaic power station.
3.3 Active power limit control
The photovoltaic power station controls the active power to be below the command value issued by the dispatching agency or below the preset value.
Note: See Figure A.1 in Appendix A.
3.4 Active power constant value control
The photovoltaic power station controls the active power at the command value or preset value issued by the dispatching agency.
3.5 Active power difference control
The photovoltaic power station is running below the available power generation, and the difference between the actual active power and the theoretical power generation is issued by the dispatching agency or pre-determined set up.
Note: See Figure A.2.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download GB/T 40289-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 19964-2024 — Technical requirements for connecting photovoltaic power station to power system
GB/T 29321-2026 — Technical specification for reactive power compensation in photovoltaic power stations
GB/T 31366-2015 — Technical requirements for monitoring and control system of photovoltaic power station
Secure payment via Stripe
Payments accepted
GB/T 40289-2021
$270.00