GB/T 37663.1-2019Outdoor empirical test requirements for distributed photovoltaic in warm damp climate—Part 1: Photovoltaic module (English PDF)
湿热带分布式光伏户外实证试验要求 第1部分:光伏组件
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 37663.1-2019 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
June 4, 2019
Implementation date
January 1, 2020
Scope
GB/T 37663.1-2019 is the English-translated version of 湿热带分布式光伏户外实证试验要求 第1部分:光伏组件.
GB/T 37663.1-2019 is the Chinese standard "Outdoor empirical test requirements for distributed photovoltaic in warm damp climate—Part 1: Photovoltaic module".
Its scope clause reads: This part of GB/T 37663 specifies outdoor empirical tests for crystalline silicon and thin film photovoltaic modules (except concentrating photovoltaic modules) for the ground.
Requirements, including sample requirements, test conditions, installation requirements, test procedures, results processing, etc. This section applies to the PV modules used in the distributed photovoltaic power generation system of China's “wet and hot” climate zone as specified in GB/T 4797.1.
Photovoltaic modules used in large-scale ground-based photovoltaic power plants, as well as China's “sub-humidity” climate zone can also be implemented. This section does not apply to double-sided PV modules.
Found what you need?
Document preview — GB/T 37663.1-2019
National Standard of the People's Republic of China
- ICS
- 27.160
- Classification
- K 04
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 sample requirements
- 5 Test conditions and devices
- 5.1 Test site and environmental conditions
- 5.2 Photovoltaic bracket installation requirements
- 5.3 Test Equipment
- 6 test sequence
- 7 performance test
- 7.1 Performance Test Project
- 7.2 Visual inspection
- 7.3 Peak Power Test
- 7.4 Insulation test
- 7.5 Wet Leakage Current Test
- 7.6 Electroluminescence test
- 7.7 Infrared Thermal Imaging
- 8 Outdoor Empirical Test
- 8.1 Test Requirements
- 8.2 Test period
- 8.3 Outdoor Empirical Test Project
- 8.4 Performance testing during maintenance and testing
- 9 test results processing
- 10 Test report
1 Scope
This part of GB/T 37663 specifies outdoor empirical tests for crystalline silicon and thin film photovoltaic modules (except concentrating photovoltaic modules) for the ground.
Requirements, including sample requirements, test conditions, installation requirements, test procedures, results processing, etc.
This section applies to the PV modules used in the distributed photovoltaic power generation system of China's “wet and hot” climate zone as specified in GB/T 4797.1.
Photovoltaic modules used in large-scale ground-based photovoltaic power plants, as well as China's “sub-humidity” climate zone can also be implemented.
This section does not apply to double-sided PV modules.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 4797.1 Classification of environmental conditions Natural environmental conditions Temperature and humidity
GB 50794-2012 Photovoltaic power station construction specification
GB 50797-2012 Photovoltaic power station design specification
IEC 60410 count check sampling and procedures (Samplingplansandproceduresforinspectionbyattributes)
Photovoltaic devices - Part 1. Measurement of photovoltaic current-voltage characteristics (Photovoltaicdevices - Part 1.
Measurementofphotovoltaiccurrent-voltagecharacteristics)
IEC 60904-2 Photovoltaic devices - Part 2. Requirements for standard solar installations (Photovoltaicdevices-Part 2. Re-
Providersforreferencesolardevices)
IEC 60904-9 Photovoltaic devices - Part 9. Performance requirements for solar simulators (Photovoltaic devices - Part 9. Solar
Simulatorperformancerequirements)
IEC 60904-10 Photovoltaic devices - Part 10. Linear method (Photovoltaic devices - Part 10. Methodsof
Linearitymeasurement)
IEC TS60904-13 Photovoltaic devices - Part 13. Electroluminescent (EL) testing of photovoltaic modules (Photovoltaic devices -
Part 13. Electroluminescenceofphotovoltaicmodules)
IEC 61215-1 Design and identification of photovoltaic modules for the surface - Part 1 . Test requirements [Terrestrialphotovoltaic (PV)modules-Designqualificationandtypeapproval-Part 1.Testrequirements]
IEC 61215-2.2016 Design and identification of surface photovoltaic modules - Part 2. Test procedures [Terrestrialphoto-
Voltaic(PV)modules-Designqualificationandtypeapproval-Part 2.Testprocedures]
IEC 61724-1 Photovoltaic system performance Part 1. Monitoring system (Photovoltaicsystemperformance-Part 1.
Monitoring)
IEC 61853-1 Photovoltaic modules - Performance testing and energy grading - Part 1 . irradiance and temperature performance testing and energy rating
[Photovoltaic(PV)moduleperformancetestingandenergyrating-Part 1. Irradianceandtemperatureper-
Formancemeasurementsandpowerrating] […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 37663.1-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 37663.2-2019 — Outdoor empirical test requirements for distributed photovoltaic in warm damp dlimate—Part 2: Photovoltaic backsheet
GB/T 37663.3-2019 — Outdoor empirical test requirements for distributed photovoltaic in warm damp climate—Part 3: Grid-connection photovoltaic system
GB/T 7251.4-2026 — Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites (ACS)
Secure payment via Stripe
Payments accepted
GB/T 37663.1-2019
$205.00