GB/T 36090-2018Gas analysis—Guide for quality assurance of on line automatic measuring system (English PDF)

气体分析 在线自动测量系统质量保证指南

Preview PDF

This is a limited preview

Buy now to download the full PDF (44 pages)

Need quotation for your management?

Get a formal quotation for GB/T 36090-2018 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

March 15, 2018

Implementation date

October 1, 2018

Scope

GB/T 36090-2018 is the English-translated version of 气体分析 在线自动测量系统质量保证指南.

GB/T 36090-2018 is a guide to the quality assurance of automated measuring systems (AMS) permanently installed on site to analyse gases.

It is built around four procedures: a laboratory evaluation before installation, with functional tests, linearity and interference checks and an uncertainty budget to confirm the AMS is fit for purpose; calibration against a standard reference method (SRM) and a variability test after installation; ongoing checks of precision and zero and span drift during operation using CUSUM control charts; and an annual surveillance of performance, calibration function and variability.

It also covers reports and the management of records and documents. Data acquisition and recording systems are outside its scope. The standard was issued on 15 March 2018 and has applied since 1 October 2018.

Found what you need?

Document preview — GB/T 36090-2018

National Standard of the People's Republic of China

ICS
71.100.20
Classification
G 86

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 symbol code
  • 5 AMS Laboratory Assessment (Procedure 1)
  • 5.1 Overview
  • 5.2 AMS Functional Test
  • 5.3 Measurement System Calibration Conditions
  • 5.4 Uncertainty assessment and applicability assessment
  • 5.5 Field Verification
  • 5.6 Report
  • 6 AMS Calibration and Variability Testing (Procedure 2)
  • 6.1 Overview
  • 6.2 Installation
  • 6.3 Functional Test
  • 6.4 Calibration
  • 6.5 Variability
  • 6.6 Report
  • 7 AMS Continuous Operation Quality Assurance (Procedure 3)
  • 7.1 Overview
  • 7.2 CUSUM Control Figure
  • 7.3 Program Reset (Initialization)
  • 7.4 Calculation Procedure
  • 7.5 Inspection of reduced accuracy
  • 7.6 Drift test and necessary adjustments
  • 8 Annual monitoring procedures (procedure 4)
  • 8.1 Functional Test
  • 8.2 SRM parallel measurement
  • 8.3 Test Process
  • 8.4 Variability calculation
  • 8.5 Calibration of variability and validity of the calibration function
  • 8.6 Report
  • 9 Record and Document Management
  • Appendix A (Normative) AMS Functional Test
  • Appendix B (Normative) Linear Test
  • Appendix C (informative) Chemical interferences
  • Appendix D (informative) UV-fluorescence method for the determination of sulphur dioxide content in ambient air
  • Appendix E (informative) Calculation and variability test examples for calibration functions
  • Appendix F (informative) Zero and range standard deviation calculation example
  • Appendix G (informative) Calibration function variability test example
  • Appendix H (informative) Records and Document Management

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

1 Scope

This standard specifies the quality assurance procedures for the online gas automatic measurement system (AMS).

--- Procedure 1, before the AMS installation, conduct a laboratory evaluation to confirm the applicability of AMS;

--- Procedure 2, after AMS installation, calibrate the AMS and evaluate the measurement variability to confirm the appropriate AMS installation Useability

--- Procedure 3, in the AMS operation, check the measurement accuracy, zero and span drift, and confirm the quality of the AMS measurement results;

--- Procedure 4, an annual monitoring program to assess the effectiveness of AMS operations, performance, calibration functions, and variability during the year.

This standard only applies to the quality assurance of AMS, and does not include the quality assurance of data acquisition and recording systems.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 14850 Gas Analysis Vocabulary (GB/T 14850-2008, ISO 7504:2001, IDT)

GB/T 27025 General requirements for testing and calibration laboratory capabilities (GB/T 27025-2008, ISO /IEC 17025:2005, IDT)

JJF1059.1 Measurement Uncertainty Evaluation and Representation

3 Terms and definitions

The following terms and definitions defined in GB/T 14850 apply to this document.

3.1 Automatic measurement system (AMS)

Automatic monitoring system permanently installed on site, including analyzers, sampling equipment, sample pretreatment equipment, etc.

3.2 Standard reference method (SRM)

In order to verify the method used for standard measuring devices that are temporarily installed in the field.

3.3 CUSUM chart

The drift and accuracy variation accumulation and control maps are compared to the uncertainty components obtained in Procedure 1.

3.4 Drift

During unattended periods, the measurement function changes with a monotonic change in the calibration function over time.

3.5 Instability

Drift and measured value changes caused by changes in the calibration function during unattended periods.

3.6 Instrument reading

The measured value directly read from the AMS without using the correction function.

3.7 Unattended time

The maximum allowable time interval for which the operating characteristics remain within a predetermined range.

3.8 Precision

The degree of consistency between consecutive zero readings and continuous range readings over a specified time interval.

3.9 Response time

AMS response time when the characteristic value suddenly changes.

3.10 Range reading

The analog input is an AMS instrument reading that is approximately 80% of the measurement range.

3.11 Variability

The standard deviation of the difference between SRM and AMS parallel measurements.

3.12 Zero reading

Instrument readings when the AMS analog input content parameter is zero.

4 Symbol code

The following symbolic codes apply to this document.

a. The intercept of the calibration function.

The best estimate of a^.a.

b. slope of the calibration function.

The best estimate of b^.b.

Bj. the amount of influence xj is the sensitivity coefficient of c in C=ctest.

Bj,max. the maximum value of bj.

C. The amount to be measured.

The measured value of c.C.

Ctest. Specifies (specifies) the measured value of C under measurement uncertainty.

Di. The difference between the SRM measurement value yi and the AMS calibration value y^i.

D. the average value of Di.

Dadjust. The amount by which the AMS makes adjustments when drift is detected.

Dt. The difference between the current reading of the AMS and the reference value.

Dt-1. The difference between the previous reading of the AMS and the reference value.

E. The specified limit.

f yi( )cal. Analytic function; excludes the input quantity function affected by the affected quantity.

Hs. Test value with reduced detection accuracy.

Hx. Test value for detecting drift.

Ij. The change in the rate of change of the measured value and the interference value xi in C=ctest.

k. contains the factor.

Ks. standard deviation tentative sum calculation constant.

Kv. variability test value.

Kx. positive and negative difference tentative value and calculation constant, AMS adjusts the calculation constant.

LV. Limit.

m. the total number of influences.

n. The total number of inputs.

N. The number of samples in the parallel measurement pair.

N(s). The number of readings when the standard deviation is not zero.

N(pos). The number of readings when a positive difference is detected.

N(neg). The number of readings when a negative difference is detected.

P. percentage value.

Sp. A standard deviation of the standard deviation of AMS (procedure 3).

St. Temporary sum of standard deviations of AMS at time t (procedure 3).

St-1. Temporary sum of standard deviations of AMS at time t-1 (procedure 3).

sD. The standard deviation of the difference Di in parallel measurements.

s[c(xj)]. The standard deviation of c obtained by xj in C=ctest.

Sxj( ). C= standard deviation of xj in ctest.

Sinst(yi). The standard deviation of yi due to unstable random parts.

Sr(yi). The repeatability standard deviation of the input quantity yi.

sR(yi). The standard deviation of the recurrence of the input quantity yi.

s(^yi). The standard deviation of the calibration value measured by the input amount Yi.

T0.975. The probability of a 97.5% t distribution.

UC. C=ctest The synthetic extended uncertainty of c (95% confidence interval).

Ureq. C=ctest specifies the (or required) extended uncertainty (95% confidence interval).

Uc.C=the standard uncertainty of the synthesis of c in ctest.

u(bj). The standard uncertainty of bj in C=ctest.

u[c(xj)]. C=ctest The extended uncertainty component of the measured value c caused by the influence amount xj.

u(xj), u(deltaxj). The standard uncertainty of the xj difference between the measurement and the associated calibration.

Up. Standard uncertainty component.

u[^c(^yi)]. The standard uncertainty component of c (the uncertainty of the calibration function of the experimentally determined input Yi).

Ufit[c(yi)]. The standard uncertainty component of c (the miscalculation of the calibration function of input Yi).

Uinst[ci(yi)]. The standard uncertainty component of c (instability random uncertainty of input Yi).

Ur[c(yi)]. The standard uncertainty component of c (repetition of input Yi).

uR[c(yi)]. The standard uncertainty component of c (input Yi recurrence).

Ureq. The maximum allowable standard uncertainty of the measured value.

u(yi). The standard uncertainty of the input quantity Yi.

Uinst. Standard uncertainty caused by instability.

Utemp. The standard uncertainty caused by the influence of temperature.

Upres. Standard uncertainty caused by the effects of pressure.

Uvolt. The standard uncertainty caused by the influence of voltage.

Uothers. Any other standard uncertainty that may affect the reading of the starting point and the reading of the range.

Wi. weighting factor of input quantity Yi

X. The amount of influence.

Xj. The jth amount of influence.

Xj. The value of Xj.

Xj,cal. The value of the influence quantity Xj in the calibration.

Xj,max. the maximum value of the influence amount xj.

Xj,min. the minimum value of the influence amount xj.

Xi. The ith measurement signal obtained by the AMS under the measurement conditions of the AMS.

x. The average value of the AMS measurement signal xi.

Reference value at xt.t (program 3).

Y. Input amount (program 1).

Yi. The ith input (program 1).

Yi. the value of Yi (program 1).

Yi,fit. The linearity of the input quantity yi in C=ctest (program 1).

Yi. The i-th result of SRM.

y. the average of the SRM results yi.

Yi, s. The value of SRM under standard conditions.

Ys, min. The minimum value of SRM under standard conditions.

Ys, max. The maximum value of SRM under standard conditions.

y^i. The best estimate of the "true value" calculated by the calibration function from the AMS measurement signal xi.

y^i,s. The best estimate of the "true value" calculated from the AMS measurement signal xi under standard conditions.

Yt. Actual instrument reading of AMS at t (proc. 3).

Z. Offset (the difference between the AMS zero reading and zero).

sum(pos)p. The temporary sum of the AMS drifts.

sum(pos)t. the sum of the positive drifts of the AMS at time t.

sum(pos)t-1. The sum of the positive drift of the AMS in the previous (t-1).

sum (neg) p. Temporary sum of AMS negative drift.

sum(neg)t. the sum of the AMS negative drift at t.

sum(neg)t-1. the sum of the AMS negative drifts of the previous time (t-1).

sAMS. The standard deviation of the AMS used in Program 3.

alpha. the level of significance.

epsiloni. The deviation between yi and the expected value.

sigma0. Uncertainty of the requirement (or regulation).

deltac(xj). The systematic deviation of c caused by xj.

deltac(xj,p). The change in c caused by the maximum positive change of the influence amount xj after calibration; note the sign including the value.

deltac(xj,n). The change in c caused by the maximum negative change of the influence amount xj after calibration; note the sign including the value.

deltaxj. The difference between the measurement and the corresponding calibration xj.

deltaxj,p. measure the maximum positive difference between xj and the corresponding calibration.

deltaxj,n. The maximum negative difference between the measured and the corresponding calibration xj.

5 AMS Laboratory Assessment (Procedure 1)

5.1 Overview

AMS should be evaluated in accordance with Procedure 1 prior to installation on the AMS site.

The evaluation laboratory shall comply with the provisions of GB/T 27025. Third-party laboratories can be hired when the factory does not have a qualified laboratory get on. The laboratory evaluation procedure (procedure 1) includes.

a) AMS functional test;

b) AMS uncertainty assessment and applicability assessment;

c) on-site verification of laboratory evaluation results;

d) Confirm the applicability of AMS.

5.2 AMS functional test

The functional test shall be consistent with the technical specifications given by the AMS supplier (manufacturer).

The functional test of AMS is shown in Appendix A. The main contents of the test include.

---AMS visual inspection;

---Zero and span check;

--- Drift test;

---Linear test;

---Interference test;

--- Response time test, etc.

See Appendix B for linear testing of AMS.

5.3 Measurement System Calibration Conditions

5.3.1 General

The calibration conditions will play an important role in determining the effect of the amount of influence on the measured value. Calibration of each input will involve The calibration condition at the time, and any change in calibration conditions in subsequent measurements will result in a deviation until recalibration is required. To this end, it should be as in 5.3.2 5.3.3 Determine the calibration conditions.

During the measurement, if the calibration is performed periodically, the change in the amount of influence between successive calibrations should be determined.

5.3.2 Chemical influence

Specify the maximum value xj,max of the chemical interference Xj in this field. In exhaust gas monitoring, if the value has no fixed information, then Use the maximum value given in Appendix C.

Specify the minimum value xj,min of the chemical interference Xj, which is usually zero.

Specify the given value of the calibration substance xj, cal. When calibrating by parallel measurement of AMS and SRM, xj,min and xj,max are usually used. The average value is taken as the value of xj, cal.

In order to be as close as possible to the matrix of the sample, it is sometimes possible to introduce the calibration material directly into the sample gas by adding a known amount of the measurement component.

In this case, the value of the chemical influence amount in the subsequent calibration is not constant. Direct estimation of the interaction between successive calibrations of dynamic processes Learn the maximum positive and negative deviation of the interference value.

5.3.3 Physical influence

If the value xj of the physical influence amount Xj (for example, temperature and pressure) is the same every time the calibration is performed, the value is taken as xj, cal, and Xj,max and xj,min should use the maximum and minimum values of the influence when measuring.

If the estimate is not the same when calibrating, the maximum positive and negative changes that occur during the measurement should be taken directly until the next calibration. (xj, max-xj, cal) and (xj, min-xj, cal) (note the sign contained in the value).

5.4 Uncertainty assessment and applicability assessment

5.4.1 Overview

The evaluation principle and general requirements for measurement uncertainty are specified in JJF1059.1. The measurement should be clearly defined.

It should be confirmed that the performance of the measurement system is valid.

The steps of the measurement procedure (eg, sampling, analysis, post-processing, and calibration) and materials (eg, reference materials) should be described. The required measurement quality should be clearly stated.

--- Required extended uncertainty Ureq (95% confidence);

--- Define the test value ctest of Ureq;

--- Define the average time of Ureq.

The evaluation process is shown in Figure 1.

5.4.2 Analytic functions, model functions, variance functions

The analytical function between the input quantity yi and the measured value c is given by equation (1).

If the influence quantity xj produces a correction term for the measured value c, the general model function of the measured value c is given by equation (2).

If the input is not related to the amount of influence, the variance of c is given by equation (3).

From equation (3), the square of the synthetic standard uncertainty uc is the weighted sum of the input and the square of the uncertainty of the influence, see equation (4).

If the uncertainty of the experimentally determined sensitivity coefficient (bj) is not negligible, then the term sum deltax2ju2(bj) should be included in equation (4).

5.4.3 Analysis of source of uncertainty
5.4.3.1 Principle requirements

The source of uncertainty should be analyzed according to the actual measurement situation, especially the main ones that have the greatest impact on the measurement uncertainty. The source of certainty should not be duplicated or missing.

Measurement errors or any unexpected events should not be considered as a source of uncertainty.

Not all sources of uncertainty need to be included in the calculation plan. Any uncertainty component does not exceed the maximum standard uncertainty If the amount is 20%, the source of uncertainty is negligible.

5.4.3.2 Uncertainty related to response time

Response time is the source of uncertainty for continuous measurement systems.

The measured value may be affected by the previous sample (hysteresis effect), or by the sampling process (eg, mixing, reversible adsorption, etc.), or the test process Affected by (eg, electronic time constants, etc.), the actual impact will depend on the response time being measured. Claim.

--- The response time should be less than 25% of the average time, at which point its impact is negligible;

--- Under high dynamic conditions, the fluctuation of the measured value within 5% of the average time is higher than the test value (ctest), then the response time should be Less than 10% of the average time. At this point, its impact is negligible.

5.4.3.3 Uncertainty related to calibration

Sources of uncertainty associated with calibration include.

---The deviation of the experimental calibration function (deviation, miscalculation);

--- Uncertainty of standard samples or reference methods;

--- (Instrumental) drift/instability and so on.

5.4.3.4 Influence of input quantity

The amount of influence on the input includes.

--- a component of the gas that may change the measured value;

--- can change the physical quantity of the measured value, such as temperature, pressure, radiation, power supply voltage and frequency;

---Chemical interference substances;

--- The influence of the operator, etc.

5.4.3.5 Others

Other various factors of uncertainty include.

---Sampling and transport effects;

--- adsorption, desorption efficiency;

---Noise, etc.

5.4.4 Estimation of uncertainty components
5.4.4.1 General

The value of the measurement system performance characteristic may be a claimed value (manufacturer's description) or an actual measured value. Any one of them can be used Determine whether the required measurement quality is met. The values used in this process should be representative in the measurement procedure.

The value of any performance characteristic may cause measurement uncertainty, and the quantification of its impact can only be performed at the test level C=ctest.

For example, the influence of the influence amount Xj includes the system deviation deltac(xj) and the random error scxj( )[ ]. Taking the square root of the mean square error as For the measurement of standard uncertainty, see equation (5).

The uncertainty of the amount of influence (xj) is calculated as shown in equation (6).

If the upper and lower limits of an influence quantity deviation are known, the standard uncertainty u(xj) can be obtained by the calculation of equation (7).

It is assumed here that the probability distribution of the quantities is a uniform (rectangular) distribution, for example, temperature; note the notation including deltaxj,p and deltaxj,n.

If the two extreme values are zero-symmetric, then equation (7) is transformed into equation (8).

Typically, the value of the performance characteristic is the result of an experimental test. Unless this contribution is rated less, the uncertainty associated with this calculation is here Cheng Cheng should be considered as an additional contribution.

5.4.4.2 Repeatability and reproducibility

The reproducibility of the input can include a variety of sources of uncertainty, such as noise, calibration uncertainty, instability/drift, operator shadow The amount of influence and environmental impact.

Reproducibility only contains random parts of the source of uncertainty. Systemic impacts from the same source should be treated separately.

Calculate the recurrence standard uncertainty uR[c(yi)] of C=ctest using the recurrence standard deviation sR(yi) of the input quantity according to equation (9).

All sources of uncertainty may be covered by reproducibility. In addition to noise, the source of uncertainty should be introduced separately in this process.

According to the formula (10), the repeatability standard uncertainty ur[c(yi)] of C=ctest is calculated by the repeatability standard deviation sr(yi) of the input amount i.

5.4.4.3 Linear

If the applied linear calibration function does not match the actual calibration function, such as nonlinearity, it is called linear miscalculation. Corresponding to C=ctest Yi=yi, the linear miscalculation of the input quantity Yi measured in test, which is the difference between the measured value of Yi of the calibration function and yi, test deltayi, fit.

The standard uncertainty corresponding to the measured value c is calculated using equation (11).

If the linear miscalculation is specified as a symmetrical upper and lower limit, for example, a percentage value ± P, the equivalent of equation (8) can be applied.

5.4.4.4 Uncertainty of the calibration function

The experimental calibration function is obtained from the measurements. Because the number of measurements is limited, there is always a residual uncertainty in the applied function.

Determine the Yi=yi corresponding to C=ctest, and the uncertainty of the calibration function of the input quantity Yi in test is the standard deviation s(^yi). According to formula (12) A standard uncertainty component corresponding to the measured value c is calculated.

5.4.4.5 Instability/Drift

Corresponding to Yi=yi of C=ctest, the change of the measured value of the input quantity Yi in test is represented by instability, which includes the system of drift D(yi) The general term and the random term sinst(yi). The standard uncertainty of the measured value c is given by equation (13).

If instability (drift) is specified as a symmetrical upper and lower limit, for example, every q days is specified as a percentage value ± P, then available The equivalent of equation (8) is used to calculate the standard uncertainty.

5.4.4.6 Selectivity

The selectivity Ij indicates that the change in the measured value c is attributed to the change in the interference value xj […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 44 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 36090-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
44 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 36090-2018

$500.00