GB/T 35031.302-2022Customer energy management system—Part 3-2: Data configuration of subsystem gateway (English PDF)
用户端能源管理系统 第3-2部分:子系统接口网关数据配置
This is a limited preview
Buy now to download the full PDF (42 pages)
Need quotation for your management?
Get a formal quotation for GB/T 35031.302-2022 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
October 14, 2022
Implementation date
May 1, 2023
Scope
GB/T 35031.302-2022 is the English-translated version of 用户端能源管理系统 第3-2部分:子系统接口网关数据配置.
GB/T 35031.302-2022 is Part 3-2 of GB/T 35031 and defines the data model of the subsystem interface gateway of a customer energy management system, together with the data that has to be configured for the gateway to exchange information with the master station.
It sets the configuration principle, then the general gateway data - gateway operation information, device basic information, device message, log, file and time parameters - the service data of commands, properties and events, the monitoring point data of meter readings, readings, meters and metered objects, the communication port and communication protocol data, and the alarm parameters.
A normative annex defines ReadingType and the commonly used readingTypeID values. It applies to the design, development and testing of data acquisition subsystem interface gateways. It was issued on 14 October 2022 and has applied since 1 May 2023.
Found what you need?
Document preview — GB/T 35031.302-2022
National Standard of the People's Republic of China
- ICS
- 29.020
- Classification
- K 00
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions, Abbreviations
- 3.1 Terms and Definitions
- 3.2 Abbreviations
- 4 Overview
- 4.1 Gateway Data Model
- 4.2 The composition of the data collected by the gateway
- 5 Gateway data configuration principle
- 6 Gateway General Data Configuration
- 6.1 Overview
- 6.2 Gateway operation information (Gateway) configuration requirements
- 6.3 Device Basic Information (DeviceInfo) Configuration Requirements
- 6.4 Device message parameter (Message) configuration requirements
- 6.5 Log parameter (Log) configuration requirements
- 6.6 File parameter (File) configuration requirements
- 6.7 Time parameter (Time) represents convention
- 7 Gateway service data configuration
- 7.1 Overview
- 7.2 Service data configuration requirements
- 7.3 Device Command (Command) Data Configuration Requirements
- 7.4 Device property (Property) data configuration requirements
- 7.5 Device event (Event) data configuration requirements
- 8 Monitoring point data configuration
- 8.1 Overview
- 8.2 Configuration Requirements for Monitor Point Parameters
- 8.3 Meter Reading (MeterReading) Configuration Requirements
- 8.4 Reading Configuration Requirements
- 8.5 Meter configuration requirements
- 8.6 MeteredObject Configuration Requirements
- 9 Communication port data configuration
- 9.1 Overview
- 9.2 Communication port (CommPort) configuration requirements
- 9.3 Communication port parameter (commPortPara) configuration requirements
- 10 Communication protocol data configuration
- 10.1 Overview
- 10.2 Communication Protocol (Protocol) Configuration Requirements
- 10.3 Communication connection parameter (ConnectionPara) configuration requirements
- 10.4 Protocol parameter (ProtocolPara) configuration requirements
- 11 Alarm parameter configuration
- 11.1 Overview
- 11.2 Alarm (Alarm) Configuration Requirements
- Appendix A (normative) ReadingType definition and commonly used readingTypeID
- A.1 ReadingType (reading type) definition
- A.2 Definition of enumeration value of each element of ReadingType
- A.3 Common readingTypeID
- Appendix B (Informative) Gateway Data Model Example
- Reference
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents" drafted.
This document is part 3-2 of GB/T 35031 "Client Energy Management System". GB/T 35031 has released the following parts.
--- Part 1: Guidelines;
--- Part 2: Master station functional specification;
--- Part 3-1.General requirements for subsystem interface gateways;
--- Part 3-2.Subsystem interface gateway data configuration;
--- Part 4: Specification for information interaction between the master station and the gateway;
--- Part 6: Management indicator system;
--- Part 7: Functional classification and system classification;
--- Part 8: Use cases.
Introduction
GB/T 35031 "User-end Energy Management System" is a recommended standard to guide the normalization of user-end energy management.
Technical requirements, data interface models, and evaluation and evaluation systems solve the problems that have long plagued my country's user-end energy management field. Difficulty in compatibility between users and different systems.
Given that the user-end energy management system involves multiple dimensions such as systems and components, hardware and software, communication protocols, data interfaces, monitoring and evaluation, etc.
The content can be clearly divided into several relatively independent but interrelated parts, so GB/T 35031 is intended to be composed of eight parts.
--- Part 1: Guidelines. Provide user-end energy management system architecture model and general requirements.
--- Part 2: Master functional specification. It includes the functional architecture, functional definition and requirements of the master station software of the client energy management system.
--- Part 3-1.Subsystem interface gateway general requirements. Contains subsystem interface gateway functional model, functional requirements and electrical, General requirements for machinery, inspection, etc.
--- Part 3-2.Subsystem interface gateway data configuration. Define the data model of the subsystem interface gateway and the data that should be configured.
--- Part 4: The master station and the gateway information interaction specification. Define the subsystem interface gateway to communicate with the master through the MQTT protocol various topics of information interaction.
--- Part 5: Application side interface specification. Define various application programming interfaces facing the application side.
--- Part 6: Management indicator system. Provide the technical index system of the user-end energy management system and the definition of each index item.
--- Part 7: Functional classification and system classification. Provides user-end energy management system function classification and system grading methods.
--- Part 8: Use cases. Sort out and summarize the forms of user-end energy services, and describe various types of user-end energy management in detail in the form of use cases and service participants, interactive information and specific processes.
The third part is about the standard of the subsystem interface gateway. Due to the long space, the content can be divided into separate chapters, so it is further divided into two parts.
Independent parts, namely subsystem interface gateway general requirements and subsystem interface gateway data configuration.
The data model and data configuration requirements of the subsystem interface gateway will lay a good foundation for ensuring the information exchange between the master station and the gateway.
On the basis of defining the data model of the subsystem interface gateway, this document includes general gateways, gateway services, monitoring points, communication ports, communication protocols, It specifies the data configuration requirements for the information exchange between the subsystem interface gateway and the master station.
1 Scope
This document defines the data model of the subsystem interface gateway, and specifies the data configuration requirements for the information exchange between the subsystem interface gateway and the master station.
This document applies to the design, development and testing of data acquisition subsystem interface gateways.
2 Normative references
The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to this document.
GB/Z 32500-2016 General requirements for data interface of smart grid client system
GB/T 35031.4-2022 Client Energy Management System Part 4: Information Interaction Specification between Master Station and Subsystem Interface Gateway
GB/Z 35031.8-2021 Client Energy Management System Part 8: Use Cases
GB/T 35031.301-2018 Client Energy Management System Part 3-1.General Requirements for Subsystem Interface Gateway
DL/T 645-2007 Multi-function energy meter communication protocol
DL/T 698.45-2017 Electric energy information collection and management system part 4-5.Communication protocol --- Object-oriented data exchange protocol
DL/T 1080.9-2013 System interface for integrated power distribution management application in power supply enterprises - Part 9: Meter reading and meter control interface
3 Terms and Definitions, Abbreviations
GB/T 35031.301-2018, GB/Z 35031.8-2021 and GB/T 35031.4-2022 as well as the following terms and definitions The meaning applies to this document.
3.1 Terms and Definitions
3.1.1 Subsystem interface gateway
An interface device used to connect the CEMS subsystem to the CEMS master station network in the client energy management system.
NOTE: Subsystem interface gateways are also referred to as "gateways" in this document.
3.2 Abbreviations
The following abbreviations apply to this document.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 42 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/Z 32500-2016General requirements of data interface for user side system of smart grid
- GB/T 35031.4-2022Customer energy management system - Part 4: Specification for information exchange between host and gateways
- GB/Z 35031.8-2021Customer energy management system - Part 8: Use cases
- GB/T 35031.301-2018Customer energy management system—Part 3-1: General requirements for subsystem gateway
- DL/T 645-2007Multi-function watt-hour meter communication protocol
- DL/T 698.45-2017Data acquisition and management system for electrical energy Part 4-5: Communication protocol-object oriented data exchange protocol
Similar standards
How to Download GB/T 35031.302-2022
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
DL/T 1080.9-2013 — Application integration at electric utilities. System interfaces for distribution management. Part9: Interfaces for meter reading and control
DL/T 645-2007 — Multi-function watt-hour meter communication protocol
DL/T 698.45-2017 — Data acquisition and management system for electrical energy Part 4-5: Communication protocol-object oriented data exchange protocol
Secure payment via Stripe
Payments accepted
GB/T 35031.302-2022
$530.00