GB/T 31911-2015Methods for determination of emissions from appliances burning gaseous fuels (English PDF)

燃气燃烧器具排放物测定方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (17 pages)

Need quotation for your management?

Get a formal quotation for GB/T 31911-2015 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

September 11, 2015

Implementation date

August 1, 2016

Scope

GB/T 31911-2015 is the English-translated version of 燃气燃烧器具排放物测定方法.

GB/T 31911-2015 is the Chinese standard "Methods for determination of emissions from appliances burning gaseous fuels".

Its scope clause reads: This standard specifies the terms and definitions, measurement systems, analyzers, auxiliary equipment and accessories, system inspection, sampling, test operations, calculation methods for the determination of NOx , CO, CO2 , O2 in emissions from appliances burning gaseous fuels.

This standard applies to the determination of emissions during type inspection and other inspections of appliances burning gaseous fuels. Its clauses include terms and definitions; system check; sampling; test operation.

Found what you need?

Document preview — GB/T 31911-2015

National Standard of the People's Republic of China

ICS
91.140
Classification
P 45

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative references4
  • 3 Terms and definitions4
  • 4 Measuring systems, analyzers, auxiliary equipment, accessories4
  • 5 System check10
  • 6 Sampling10
  • 7 Test operation11
  • 8 Calculation methods12
  • Appendix A (Informative) Test gas and its characteristics15
  • results in gas combustion emissions17
  • Appendix C (Informative) Concentration unit conversion and result correction25

1 Scope

This standard specifies the terms and definitions, measurement systems, analyzers, auxiliary equipment and accessories, system inspection, sampling, test operations, calculation methods for the determination of NOx , CO, CO2 , O2 in emissions from appliances burning gaseous fuels.

This standard applies to the determination of emissions during type inspection and other inspections of appliances burning gaseous fuels.

2 Normative references

The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document;

for the undated documents, only the latest version (including all the amendments) is applicable to this standard.

GB 16410 Domestic gas cooking appliances

GB 25034 Gas-fired heating and hot water combi-boilers

CJ/T 28 Chinese cooking gas appliances

JJF 1059.1 Evaluation and expression of uncertainty in measurement

JJF 1001 General terms in metrology and their definitions

3 Terms and definitions

The terms and definitions, as defined in JJF 1001, apply to this document.

4 Measuring systems, analyzers, auxiliary equipment, accessories

4.1 Measurement system

4.2 Analyzer

4.2.1 Category

This standard applies to analyzers with the following measurement principles:

a) An analyzer, that uses the principle of chemiluminescence to measure NO x concentration;

b) When the NO x concentration is greater than 100×10

-6 m

3

/m

3 , an analyzer uses the infrared or ultraviolet absorption principle to measure the NO x concentration;

c) Analyzers that measure CO and CO2 concentrations, using the principle of infrared or ultraviolet absorption;

d) Analyzer that uses the paramagnetic principle to measure O 2 concentration.

4.2.2 Indication error

The indication error of the analyzer shall not exceed ±5%.

4.2.3 Repeatability

Analyzer repeatability shall not be greater than 2%.

4.2.4 Response time

The response time -- from adding standard gas to displaying 90% of the indicated concentration -- shall not be greater than 20 s.

4.2.5 Stability

The change in the indication value within 1 hour shall not be greater than 5%.

4.2.6 Interference

Analyzer measurements shall consider interference from CO2 , O2 , H2 O. Interferences can be corrected, using correction data provided by the manufacturer or a standard gas of the same concentration.

4.3 Auxiliary equipment

4.3.1 Sampler
4.3.1.1 General requirements

The sampler shall be made of materials, that do not chemically react with the sample to be tested, have no or weak adsorption, ensure the homogeneity of specimen.

4.3.1.5 Commercial gas stoves

Commercial gas stove samplers and their sampling locations shall comply with the requirements in CJ/T 28.

4.3.2 Condenser or permeation dryer

The condenser material in contact with the specimen shall be made of glass, polytetrafluoroethylene or stainless steel; its capacity shall match the sampling gas flow rate and water vapor concentration. The dew point temperature of the flue gas, at the outlet of the condenser or permeation dryer, shall be below the ambient temperature;

the cooling temperature should be between 2 °C and 5 °C; the condensate shall be able to be quickly recovered to reduce contact with the specimen. Desiccant shall not be used.

When the penetration drying method is used, one-half of the dryer tube shall be heated to at least 15 K above the gas dew point and shall comply with the manufacturer's air purging requirements.

4.3.3 Filters

The filter shall be installed between the condenser and distributor. The material in contact with the specimen shall be made of stainless steel or glass. Filter size shall be determined, based on the sample gas flow rate and the flow rate per unit area data provided by the manufacturer. The filter diameter shall not be larger than 1 µm;

contaminants on the filter shall be prevented from reacting with the gas.

4.3.4 Distributor

The material of the distributor shall be stainless steel or polytetrafluoroethylene. The volume shall be as small as possible; the upper flow limit shall ensure the specimen flow required by each analyzer. Each analyzer shall be able to be connected independently and shall have a discharge system leading to the outdoors.

4.3.5 Flowmeter

The flowmeter material shall be made of corrosion-resistant materials; the measurement range shall be selected, according to the sample flow rate, which is required by each analyzer.

4.3.6 Sampling pump

The materials of the sampling pump, which is in contact with gas, shall be made of polytetrafluoroethylene, stainless steel and other materials, that do not react with the specimen. The pump flow rate shall be at least 1.1 times the sum of the flow rates, which are required by all analyzers in the system.

4.4 Accessories

Auxiliary equipment and devices in contact with the specimen, such as regulators, valves, pipelines, joints, etc., shall be made of stainless steel, polytetrafluoroethylene, glass and other materials, that do not adsorb and do not react chemically with them.

When the specimen temperature is higher than 250 °C and the NOx component needs to be measured, stainless steel materials shall not be used in the parts in contact with it.

The diameter of the pipeline shall be determined according to the specimen flow rate, which should be 4 mm ~ 8 mm; however, it shall not be less than 4 mm.

5 System check

5.1 Air tightness inspection

Under normal pressure conditions, after inputting the normal pressure standard gas at point 1 in Figure 1, introduce the standard gas at calibration point 7. The difference between the measured values at the two points shall not exceed ±5% of the indication value. The air tightness of the sampling pipeline, at the front end of the analyzer, shall be inspected at least once a month.

5.2 Linearity inspection

The linearity inspection shall control four measuring points of 0%, 20%, 50%, 80% of the analyzer range. For the nonlinear calibration curve, at least 10 measuring points of the analyzer range shall be controlled; the deviation of each point shall not exceed ±5%.

Linearity inspection shall be performed annually or after equipment maintenance.

6 Sampling

6.1 Conditions

Burning appliances shall use the test gas, which is required by the current relevant national standards, operate under the heat flow rate corresponding to the gas supply pressure. Conduct the test when a thermal equilibrium state is reached.

6.2 Methods

The following methods can be used for sampling:

- Dry (elimination of water vapor) sampling method;

- Wet sampling method.

6.3 Dry sampling and configuration

The temperature of the upstream pipeline of the condenser or dryer shall be controlled and maintained, at least 15 K above the water dew point temperature and the acid dew point temperature of the specimen gas.

6.4 Wet sampling and configuration

In addition to dry sampling requirements, wet sampling shall also comply with the following requirements:

a) There shall be no cooler or dryer on the sampling pipeline;

b) The temperature of the sampling pipeline upstream of the analyzer shall be maintained, at least 15 K above the water dew point and the acid dew point of the specimen gas;

c) The analyzer is specially designed;

d) The water vapor in the specimen shall be corrected.

7 Test operation

7.1 Instrument warm-up

Before measurement, the instrument shall be set up and reach a stable state, in accordance with the instructions provided by the manufacturer.

7.2 Adjustment

If necessary, the test system shall be adjusted; the standard gas shall be introduced directly into the analyzer through the pipeline (Figure 1, calibration point 7; Figure 2, calibration point 6). The flow rate, temperature, pressure shall be adjusted and consistent with those measured, meanwhile they shall be within the normal range specified by the manufacturer.

Follow these steps to adjust the analyzer:

a) Introduce the zero point gas into the analyzer; adjust it to zero;

b) Then introduce a standard gas with a known concentration of approximately 80% of the full scale; adjust the reading;

c) Introduce the zero point gas again; check whether the reading is zero. If not, repeat the above operation.

7.3 Test

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

Similar standards

How to Download GB/T 31911-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 31911-2015

$295.00