Valid

GB/T 29635-2013GC and GC-MS examination methods for heroin in suspected drug (English PDF)

疑似毒品中海洛因的气相色谱、气相色谱-质谱检验方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 29635-2013 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

July 19, 2013

Implementation date

November 1, 2013

Scope

GB/T 29635-2013 is the English-translated version of 疑似毒品中海洛因的气相色谱、气相色谱-质谱检验方法.

GB/T 29635-2013 is the Chinese standard "GC and GC-MS examination methods for heroin in suspected drug". Its scope clause reads: This standard specifies the heroin gas chromatography - mass spectrometry (GC-MS) and qualitative analysis by gas chromatography (GC) quantitative analysis.

This standard applies to solid samples of heroin drug cases qualitative and quantitative inspection and appraisal. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 29635-2013

National Standard of the People's Republic of China

ICS
13.310
Classification
A 92

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 5 Reagents and reference materials, instruments and appliances volume

1 Scope

This standard specifies the heroin gas chromatography - mass spectrometry (GC-MS) and qualitative analysis by gas chromatography (GC) quantitative analysis.

This standard applies to solid samples of heroin drug cases qualitative and quantitative inspection and appraisal.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein

Member. For undated references, the latest edition (including any amendments) applies to this document.

GA/T 122 toxicological analysis Terminology

JJF1059.1-2012 Evaluation and Expression of Uncertainty in Measurement

3 Terms and Definitions

Terms and definitions GA/T 122 defined apply to this document.

Principle 4

This method uses the internal standard method or external standard method for quality control of drugs in solid samples of suspected heroin organic solvent extraction using

Gas chromatography - mass spectrometry (GC-MS) qualitative analysis by gas chromatography - flame ionization detector (GC-FID) of heroin were

Quantitative analysis.

5 Reagents and reference materials, instruments and appliances volume

5.1 Reagents and Standards

The reagents used were of analytical grade reagents and reference materials include.

a) chloroform.

b) methanol.

c) extraction reagent preparation. chloroform and methanol mixed at a ratio of 9.1 to prepare an extraction reagent.

d) traceable standard substance. heroin.

e) quantified by external standard 1.0mg/mL standard stock solution heroin. heroin weighed standard substance (according to the standard material purity and salt type

After the conversion is equal to 50.0mg heroin), into 50mL volumetric flask, dissolved by shaking after 20mL extraction solvent is added, with

The extraction solvent is diluted to the mark, the preparation of 1.0mg/mL standard stock solution of heroin, home refrigerator freezer to save, save for six

Months.

f) external standard quantitation using 0.1mg/mL heroin working standard solution. Pipette 1.0mg/mL standard solution 5mL added heroin

To 50mL volumetric flask, dilute to the mark with the extraction solvent to prepare a 0.1mg/mL heroin working standard solution, set the refrigerator […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 29635-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 29635-2013

$165.00