Valid

GB/T 2904-2010Nickel-Chromium/Gold-Iron,Copper/Gold-Iron low temperature thermocouple wires (English PDF)

镍铬-金铁、铜-金铁低温热电偶丝

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 2904-2010 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 1, 2010

Implementation date

May 1, 2011

Scope

GB/T 2904-2010 is the English-translated version of 镍铬-金铁、铜-金铁低温热电偶丝.

GB/T 2904-2010 is the Chinese standard "Nickel-Chromium/Gold-Iron,Copper/Gold-Iron low temperature thermocouple wires".

Its scope clause reads: This standard specifies the nickel-chromium - Gold and Iron, Copper - Gold and Iron thermocouple wire product classification, technical requirements, test methods, inspection rules, modes of supply, Packaging and logo.

This standard applies to the manufacture of industrial nickel-chromium - Gold and Iron, Copper - Gold and Iron alloy thermocouple wire (hereinafter referred to as dual wire). Its clauses include product categories.

Found what you need?

Document preview — GB/T 2904-2010

National Standard of the People's Republic of China

ICS
17.200.20
Classification
N 11
Replacing
GB/T 2904-1982

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Product Categories
  • 3.1 Product name, code and nominal chemical composition
  • 3.2 grade thermocouple wire
  • 3.3 Recommended temperature range
  • 3.4 tag example

1 Scope

This standard specifies the nickel-chromium - Gold and Iron, Copper - Gold and Iron thermocouple wire product classification, technical requirements, test methods, inspection rules, modes of supply,

Packaging and logo.

This standard applies to the manufacture of industrial nickel-chromium - Gold and Iron, Copper - Gold and Iron alloy thermocouple wire (hereinafter referred to as dual wire).

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent

Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research

Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.

GB/T 16701 precious metal, metal thermocouple wire thermal EMF measurement

3 Product Categories

3.1 Product name, code and nominal chemical composition

Product name, code and the name of the chemical composition as shown in Table 1.

Table 1 Categories and nominal chemical composition

Product Name polarity code

Nominal chemical composition (mass fraction) /% nominal chemical composition (atomic fraction) /%

Ni Cr Cu Au Fe

Nichrome wire cathode NiCr 90 10 - - -

Copper cathode Cu - - 100 - -

Gold-iron alloy wire negative AuFe - - - 99.93 0.07

3.2 grade thermocouple wire

Thermocouple wire according to requirements and thermoelectric properties were divided into grade I, II grade, grading technical conditions see the technical requirements.

3.3 Recommended temperature range

Thermocouple constituted by a dual wire, and its sub-degree numbers and recommended temperature range as shown in Table 2.

Table 2 dual wire recommended temperature range

Name thermocouple sub-degree temperature range/°C

Nickel-chromium - Gold and Iron NiCr-AuFe -273 ~ 7

Copper - Gold and Iron Cu-AuFe -270 ~ -196

3.4 tag example

Products labeled in the following format.

Gold and Iron thermocouple wires GB/T 2904-AuFe-I-0.2

Tag of each element have the following meanings.

AuFe --- Product Code (NiCr, Cu, AuFe);

I --- tolerance level;

0.2 --- Product Specifications.

3.5

Product-related physical parameters in Appendix A.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

Editions of GB/T 2904

EditionTitleRevisionStatus
GB/T 2904-2010Nickel-Chromium/Gold-Iron,Copper/Gold-Iron low temperature thermocouple wirescurrent editionCurrent
GB/T 2904-1982Nickel-Chromium/Gold-Iron,Copper/Gold-Iron low temperature thermocouple wiresprevious editionSuperseded

This page sells the current edition, GB/T 2904-2010. Earlier editions are listed for reference only.

How to Download GB/T 2904-2010

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 2904-2010

$165.00