Scope

GB/T 26779-2021 is the English-translated version of 燃料电池电动汽车加氢口.

GB/T 26779-2021 covers the refuelling receptacle of a hydrogen fuel cell electric vehicle, the component assembly on the vehicle that the hydrogenation gun connects to.

It gives the model designation, the general requirements - interface type and size to Annex A, a check valve in the design, the antifreeze design of Annex B - and the performance requirements for air tightness, vibration resistance, temperature resistance, durability, oxygen and ozone aging resistance, compatibility, hydrostatic strength, salt spray corrosion resistance and temperature cycling, each with its test method.

Among the figures are 15 000 durability cycles, vibration from 5 Hz to 60 Hz and 8 h at 85 degrees Celsius. It applies to receptacles using compressed hydrogen up to 70 MPa.

It replaces GB/T 26779-2011, was issued on 9 March 2021 and has applied since 1 October 2021.

Found what you need?

Document preview — GB/T 26779-2021

National Standard of the People's Republic of China

ICS
43.080.01
Classification
T47
Replacing
GB/T 26779-2011

Issued by: State Administration for Market Regulation; Standardization Administration of China

Contents

  • Foreword3
  • 1 Scope5
  • 2 Normative references5
  • 3 Terms and definitions5
  • 4 Model5
  • 5 Requirements6
  • 5.1 General requirements6
  • 5.2 Performance requirements6
  • 6 Test methods8
  • 6.1 General8
  • 6.2 Appearance and size inspection8
  • 6.3 Air tightness test8
  • 6.4 Vibration resistance test8
  • 6.5 Temperature resistance test9
  • 6.6 Durability test9
  • 6.7 Oxygen aging resistance test9
  • 6.8 Ozone aging resistance test9
  • 6.9 Compatibility test9
  • 6.10 Hydrostatic pressure strength test10
  • 6.11 Salt spray corrosion resistance test10
  • 6.12 Temperature cycle resistance test10
  • 6.13 Compatibility test10
  • 7 Marks11
  • Annex A (normative) Receptacle structure type12
  • Annex B (informative) Antifreeze design of receptacle15

Foreword

This Standard was drafted in accordance with the rules given in GB/T 1.1-2009 "Directives for standardization - Part 1: Structure and drafting of standards".

This Standard replaces GB/T 26779-2011 "Fuel cell electric vehicles - Refueling receptacle". Compared with GB/T 26779-2011, in addition to structural adjustments and editorial changes, the main technical changes are as follows.

- added the ozone aging resistance test (see 5.2.6);

- added the salt spray corrosion resistance test (see 5.2.9);

- added the temperature cycle resistance test (see 5.2.10);

- added the compatibility test (see 5.2.11);

- added the 70MPa receptacle size (see Figure A.3);

- added an informative appendix for the antifreeze design of receptacle (see Annex B);

- modified the processing requirements of 35MPa receptacle (see Figure A.1, Figure A.2, Figure A.1 of Edition 2011 and Figure A.3 of No. 1 Amendment);

- deleted the anti-static design (see 5.1.4 of Edition 2011);

- deleted the hydrogen embrittlement requirements of materials (see 5.1.6 of Edition 2011);

- deleted the chapter of inspection rules (see Chapter 7 of Edition 2011);

- deleted the size design of 25MPa receptacle (see Figure A.1 of Edition 2011).

1 Scope

This Standard specifies types, marks, requirements and test methods for hydrogen fuel cell electric vehicle refueling receptacle.

This Standard is applicable to the hydrogen fuel cell electric vehicle refueling receptacle that uses compressed hydrogen as working medium, the rated filling pressure does not exceed 70MPa, the working temperature is -40°C~85°C.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

GB/T 1690-2010, Rubber, vulcanized or thermoplastic - Determination of the effect of liquids

GB/T 10125, Corrosion tests in artificial atmospheres - Salt spray tests

GB/T 24548, Fuel cell electric vehicles - Terminology

3 Terms and definitions

For the purposes of this document, the terms and definitions defined in GB/T 24548 as well as the followings apply.

3.1 Receptacle

a component assembly connected to the hydrogenation gun on the vehicle

3.2 Nominal working pressure

in the standard state, the designed rated filling pressure

4 Model

The receptacle model consists of the following four parts.

Modified serial number (in Arabic numerals, such as 01, 02);

Matched basic size of receptacle and hydrogenation gun (such as 40/18);

5 Requirements

5.1 General requirements

5.1.1 The interface type and size shall meet the requirements of Annex A.

Designs such as chamfering, protective cover fixing groove, hexagonal shape that are easy to install are allowed. Such design shall not affect the normal engagement of the hydrogenation gun.

5.1.2 In order to solve the freezing problem of hydrogenation gun caused by hydrogen pre-cooling, refer to Annex B for the design of receptacle.

5.1.3 A check valve shall be included in the design of receptacle.

5.2 Performance requirements

5.2.1 Air tightness

Carry out the air tightness test according to the method specified in 6.3. First use a leak detector to check. If no bubbles are generated within 1min, it is conforming. If bubbles occur, continue using the leak detector or other methods to measure.

5.2.2 Vibration resistance

Carry out the vibration resistance test according to the method specified in 6.4.

All connectors shall not be loose. Its air tightness shall meet the requirements of 5.2.1.

5.2.3 Temperature resistance

Carry out the temperature resistance test according to the method specified in 6.5. There shall be no air bubbles.

5.2.5 Oxygen aging resistance

For the seals in contact with hydrogen at the receptacle, carry out the oxygen aging test according to the method specified in 6.7.

5.2.6 Ozone aging resistance

For the seals in contact with air at the receptacle, carry out the ozone aging resistance test according to the method specified in 6.8. There shall be no obvious deformation, deterioration, spots, cracks and so on.

5.2.7 Compatibility

For the non-metal parts in contact with hydrogen at the receptacle, carry out the compatibility test according to the method specified in 6.9. Its volume expansion rate shall not be greater than 25%.

5.2.8 Hydrostatic strength

The pressure-bearing parts of the receptacle shall be subjected to the hydrostatic strength test according to the method specified in 6.10. There shall be no cracks or permanent deformation.

5.2.9 Salt spray corrosion resistance

Test according to the method specified in 6.11. The receptacle shall not show signs of corrosion or peeling off the protective layer. The receptacle shall meet the air tightness requirements specified in 5.2.1.

5.2.11 Compatibility

Only the receptacle with a nominal working pressure of 70MPa needs to be tested for compatibility. Carry out the compatibility test according to the method specified in 6.13. After the test, there shall be no abnormal wear and shall meet the requirements for air tightness in 5.2.1.

6 Test methods

6.1 General

Unless otherwise specified, the test shall be carried out under the following conditions.

6.2 Appearance and size inspection

Use visual inspection for the appearance inspection of receptacle. Size measurement can be added if necessary.

6.3 Air tightness test

When the check valve of the receptacle is closed, at the outlet end of receptacle, access with leak detection gas. Respectively test under two pressure states of 0.5MPa and 1.25 times the nominal working pressure.

6.4 Vibration resistance test

Reliably fix the test piece on the vibration test bench. From 5Hz~60Hz, each integer frequency point needs to vibrate 8min, 448min in total. The amplitude is shown as Table 2.

6.5 Temperature resistance test

The check valve of the receptacle is closed. Fill the outlet end of the receptacle with a leak detection gas whose pressure is the nominal working pressure. Put it in an incubator. The temperature rises from room temperature to 85°C±2°C.

Keep the temperature for 8h. Immerse in 85°C water for 1min. Record whether there are bubbles.

6.6 Durability test

The durability test is carried out according to the following steps. The total number of cycles is 15000.

6.7 Oxygen aging resistance test

The seals in contact with hydrogen at the receptacle shall be placed in oxygen at a temperature of 70°C±2°C and a pressure of 2MPa for 96h. Observe the changing state.

6.8 Ozone aging resistance test

The seals in contact with air at the receptacle shall be placed in the air at a temperature of 40°C±2°C and an ozone volume fraction of 5 x 10^-7 for 120h. Observe the changing state.

6.9 Compatibility test

After the non-metal parts in contact with hydrogen at the receptacle shall be immersed in hydrogen at the nominal working pressure and room temperature for 168h, from the decompression, within 5min, the volume change rate and mass change rate shall be measured according to 7.2 and 7.3 of GB/T 1690-2010. The number of test sample is one.

6.10 Hydrostatic pressure strength test

Seal the outlet end of the receptacle. Access with hydrostatic pressure of 3 times the nominal working pressure. The duration shall not be less than 1min.

6.11 Salt spray corrosion resistance test

The temperature in the salt spray box shall be kept between 33°C~36°C. The receptacle is in horizontal support and exposed to the salt spray that is composed of 5% sodium chloride and 95% distilled water in accordance with GB/T 10125.

6.12 Temperature cycle resistance test

After pressurizing to nominal working pressure, put the receptacle in a thermostat. The temperature shall rise from 15°C to 85°C within 0.5h. Keep it at this temperature for 2h. Then drop from 85°C to -40°C within 1h. Keep it at this temperature for 2h.

6.13 Compatibility test

The compatibility test shall be carried out in accordance with the following steps.

7 Marks

There shall be obvious related marks including working pressure and hydrogen signs on the inside of the protective cover outside the receptacle, for example, "35MPa, hydrogen" "70MPa, hydrogen" "35MPa, H2" "70MPa, H2".

Annex A (normative) Receptacle structure type

Figure A.1~Figure A.3 specify the structure of the receptacle under different pressures. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 26779

EditionTitleRevisionStatus
GB/T 26779-2021Fuel cell electric vehicles - Refuelling receptaclefirst revisionCurrent
GB/T 26779-2011Fuel cell electric vehicles - Refuelling receptaclefirst issueSuperseded

This page sells the current edition, GB/T 26779-2021. Earlier editions are listed for reference only.

How to Download GB/T 26779-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
19 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 26779-2021

$195.00