Scope
GB/T 29124-2025 is the English-translated version of 燃料电池电动汽车配套设施规范.
GB/T 29124-2025 is the Chinese national standard covering the ground facilities a hydrogen fuel cell fleet needs — the fuelling interface and the pressure levels, the ventilation and gas detection of an indoor space where a vehicle may leak hydrogen, the maintenance workshop, the parking, and the requirements that follow from hydrogen being lighter than air. It replaces GB/T 29124-2012, under the Ministry of Industry and Information Technology. In force from 1 March 2026. Issued on 29 August 2025, it has been in force since 1 March 2026, replacing GB/T 29124-2012.
Document preview — GB/T 29124-2025
National Standard of the People's Republic of China
- ICS
- 43.020
- Classification
- T 04
- Replacing
- GB/T 29124-2012
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- Introduction5
- 1 Scope6
- 2 Normative References6
- 3 Terms and Definitions7
- 4 General Requirements7
- 5 Hydrogen Fueling Stations and Fueling8
- 5.1 Requirements for Hydrogen Fueling Stations8
- 5.2 Fueling9
- 6 Repair Workshop9
- 6.1 Hardware Requirements9
- 6.2 Operational Requirements10
- 7 Parking Lot10
1 Scope
This document specifies the terms and definitions, as well as the relevant requirements for facilities supporting the operation of fuel cell electric vehicles (hereinafter referred to as the “facilities”).
This document applies to hydrogen fueling stations, repair workshops and parking lots supporting the operation of fuel cell electric vehicles that use compressed gaseous hydrogen as fuel and have an onboard hydrogen system with a nominal operating pressure not exceeding 70 MPa (hereinafter referred to as the “vehicles”).
2 Normative References
GB 2894
GB 12158
GB/T 24548
GB/T 24549
GB/T 26779
GB/T 34425
GB/T 34584
GB/T 43674
GB 50016
GB 50057
GB 50058
GB 50067
GB 50156
GB 50516
GB 50736
GB 55037
3 Terms and Definitions
The terms and definitions defined in GB/T 24548, GB/T 24549, GB/T 43674 and GB 50067, and the following are applicable to this document.
3.1 Facilities
Hydrogen fueling stations, repair workshops and parking lots required to ensure vehicle operation.
3.2 Repair workshop
Buildings (structures) used for the maintenance and repair of powered, non-track-based buses, trucks and special-purpose vehicles, etc.
[source. GB 50067-2014, 2.0.2, modified]
3.3 Parking Lot
Open areas or buildings (structures) used for parking powered, non-track-based buses, trucks and special-purpose vehicles, etc.
NOTE. it includes open-air parking lots and garages.
[source. GB 50067-2014, 2.0.3, modified]
3.3.1 Open area
A place with no obstructions on all sides and the roof, or a structure that does not hinder the diffusion of hydrogen into the external environment.
3.3.2 Garage
Buildings (structures) used for parking powered, non-track-based buses, trucks and special- purpose vehicles, etc.
[source. GB 50067-2014, 2.0.1, modified]
4 General Requirements
4.1 The structure and performance of the facilities shall be approved by the authorized authority and comply with requirements of the relevant standards. In addition, administrative licenses or registration shall be obtained from the local administrative department pursuant to law. The operation management system of the facilities shall include a comprehensive organizational management system, safety management system, safety operating procedures, safety production responsibility system, risk management system, and emergency repair personnel and equipment.
4.2 The facilities shall ensure good ventilation, a flat floor without water accumulation, and unobstructed access for vehicles. Electrical equipment shall comply with the requirements of GB 50058, anti-static devices of the facilities shall comply with the requirements of GB 12158, and lightning protection devices shall comply with the requirements of GB 50057.
4.3 Fire protection and grounding signs of the facilities shall comply with the requirements of GB 2894, and anti-static signs shall comply with the requirements of GB 12158.
4.4 The ventilation system of the facilities shall comply with the requirements of GB 50016, GB 50736 and GB 55037.
4.5 The facilities with areas where hydrogen gas may accumulate and ignite shall be equipped with a forced air-exhaust system. Outdoor exhaust vents shall be located vertically upward and at least 2 meters above the roof ridge or operating platform, and at least 5 meters above the ground.
4.6 The facilities shall be equipped with a hydrogen gas detector and alarm that will issue an alarm signal when the set threshold is reached, except in open areas.
4.7 The facilities shall be equipped with a fire detection system, fire extinguishing system, fire water supply facilities, and access for fire trucks. Portable fire extinguishers shall also be provided. The fire protection design shall comply with the requirements of GB 50016 and GB 55037, except in open areas.
5 Hydrogen Fueling Stations and Fueling
5.1 Requirements for Hydrogen Fueling Stations
5.1.1 Hydrogen fueling station operators, maintenance personnel, and other relevant personnel
entering the workplaces shall first eliminate their own static electricity, and shall not wear synthetic work clothes, work hats or spiked shoes. Fire sources are strictly prohibited.
5.1.2 The ventilation system within the hydrogen fueling stations shall comply with the
requirements of GB 50516.The configuration of hydrogen gas detectors, alarms, electrical facilities and fire-fighting facilities shall comply with the requirements of GB/T 34584.
5.1.3 The spacing between vehicles within the hydrogen fueling stations shall meet the
conditions of emergency evacuation, and the longitudinal spacing between queuing vehicles should be greater than 1.5 meters. ......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 2894Safety colours and safety signs
- GB 12158General requirements for preventing electrostatic accidents
- GB/T 24548Fuel cell electric vehicles - Terminology
- GB/T 24549Fuel cell electric vehicles—Safety requirements
- GB/T 26779Fuel cell electric vehicles - Refuelling receptacle
- GB/T 34425Fuel cell electric vehicles hydrogen refueling nozzle
GB/T 43674 · GB 50057 · GB 50058 · GB 50067 · GB 50156 · GB 50516 · GB 50736 · GB 55037
Editions of GB/T 29124
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 29124-2025 | Specifications for fuel cell electric vehicles facilities | current edition | Current |
| GB/T 29124-2012 | Hydrogen fuel cell vehicles facilities for demonstration specifications | previous edition | In force |
This page sells the current edition, GB/T 29124-2025. Earlier editions are listed for reference only.
How to Buy GB/T 29124-2025
- 1Add to cart. Click the "Buy GB/T 29124-2025" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 12158-2024 — General requirements for preventing electrostatic accidents
GB 2894-2025 — Safety colours and safety signs
GB 50016-2014 — Code for Fire Protection Design of Buildings (2018 Edition)
Secure payment via Stripe
Payments accepted
GB/T 29124-2025
$170.00