GB/T 26117-2022Miniature electric pumps—Testing method (English PDF)
微型电泵 试验方法
This is a limited preview
Buy now to download the full PDF (24 pages)
Need quotation for your management?
Get a formal quotation for GB/T 26117-2022 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
March 9, 2022
Implementation date
October 1, 2022
Scope
GB/T 26117-2022 is the English-translated version of 微型电泵 试验方法.
GB/T 26117-2022 is the Chinese national method for testing miniature electric pumps. It gives the tests themselves - the hydraulic performance, the electrical measurements, the self-priming behaviour, the noise and the endurance - together with the test records to be kept and the content of the test report.
It applies to miniature pumps in which the motor and the pump are built on the same shaft. Pump makers, the appliance manufacturers that build them in and test houses use it.
It replaces GB/T 26117-2010, was issued on 9 March 2022 and has applied since 1 October 2022.
Found what you need?
Document preview — GB/T 26117-2022
National Standard of the People's Republic of China
- ICS
- 23.080
- Classification
- J 71
- Replacing
- GB/T 26117-2010
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms, Definitions and Symbols
- 3.1 Terms and Definitions
- 3.2 Symbol
- 4 Experiment
- 4.1 Basic requirements
- 4.2 Guarantee
- 4.3 Test equipment, test devices and test instruments
- 4.4 Measurement uncertainty
- 4.5 Test conditions
- 4.6 Micromotor test
- 4.7 Pump performance test
- 4.8 Cavitation allowance (NPSH) test
- 4.9 Determination of pump vibration and noise
- 4.10 Self-priming performance test
- 4.11 Safety Requirements
- 5 Test records and test reports
- 5.1 Record
- 5.2 Test report
- Appendix A (Informative) Sample Test Report
- Reference
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents" drafted.
This document replaces GB/T 26117-2010 "Micro-pump test method", compared with GB/T 26117-2010, except for structural adjustment Apart from editorial changes, the main technical differences are as follows.
--- Changed the scope (see Chapter 1, Chapter 1 of the.2010 edition);
--- Changed normative references (see Chapter 2, Chapter 2 of the.2010 edition);
--- Added terms, definitions and symbols (see Chapter 3);
--- Delete the relevant provisions of the test content (see 3.1 of the.2010 edition);
--- Increased test assurance requirements (see 4.2);
--- Changed the pump test acceptance level and the corresponding tolerance coefficient value (see Table 2, Table 7 of the.2010 edition);
--- Added the definition of K in the calculation formula of the straight pipe length (L) of the inlet section (see 4.3.2);
--- Increased the accuracy requirements of instruments (see 4.3.3.2);
--- Changed the allowable fluctuation range of the measured value (see Table 3, Table 2 of the.2010 edition);
--- Added "Level 3" related requirements (see 4.5.1.2, 4.5.1.3, 4.7.8, 4.7.4.3.4);
--- Delete the provisions for the system uncertainty of each measurement parameter (see Table 1 of the.2010 edition);
--- Delete the situation that the maximum allowable fluctuation range is large when the transmission signal of the measurement system is automatically recorded or accumulated by the measurement device (see 3.3.1.2.2 of the.2010 version);
--- Changed the relevant provisions of "number of observation groups" (see Table 4, 3.3.1.3 of the.2010 edition);
--- Delete the relevant requirements for the determination of measurement uncertainty (see 3.5.7 of the.2010 edition);
--- Increased the operating thermal stability requirements of the motor (see 4.5.1.4);
--- Increased the length requirements for the cables leading out of the test pump (see 4.5.3);
--- Changed the no-load test of the motor (see 4.6.3, 3.4.3.1 of the.2010 edition);
--- Increased the requirements for reducing the current load method (see 4.6.4.2);
--- Changed the range requirements of winding temperature rise at rated power [see 4.6.5.2, 3.4.4.2b) of the.2010 edition];
--- Changed the test requirements (see 4.7.1, 3.5.1 of the.2010 edition);
--- Increased the guarantee conditions during the test (see 4.7.2);
--- Added test curve requirements (see 4.7.7.2);
--- Increased the tolerance of the guaranteed value of the motor parameters (see Table 6);
--- Changed the test of self-priming performance (see 4.10, 3.8 of the.2010 edition);
--- Increased safety requirements (see 4.11).
1 Scope
This document specifies the tests, test records and test reports for micro-pumps.
This document applies to micro-electric pumps with coaxial motors and pumps (hereinafter referred to as pumps).
2 Normative references
The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to this document.
GB/T 1032 Three-phase asynchronous motor test method
GB/T 3214 Determination method of water pump flow
GB/T 3216-2016 Rotary Power Pump Hydraulic Performance Acceptance Test Level 1, Level 2 and Level 3
GB/T 9651 Test method for single-phase asynchronous motor
GB/T 14711 General safety requirements for small and medium rotating electrical machines
GB/T 22719.1 Inter-turn insulation of scattered windings of AC low-voltage motors Part 1: Test methods
GB/T 22719.2 Inter-turn insulation of scattered windings of AC low-voltage motors Part 2: Test limits
GB/T 29529 Noise Measurement and Evaluation Methods for Pumps
GB/T 29531 Pump Vibration Measurement and Evaluation Method
3 Terms, Definitions and Symbols
3.1 Terms and Definitions
The terms and definitions defined in GB/T 3216-2016 and the following terms and definitions apply to this document.
3.1.1 Pump unitefficiency
Pump output power divided by motor input power.
3.1.2 Terminal resistance
The arithmetic mean value of the resistance between the lead wires of each two-phase mains connection of a polyphase AC motor.
3.1.3 Thermally stable
The temperature rise of the heating parts of the motor does not change by more than 1K within half an hour.
3.1.4 Temperaturerise
When the motor is in rated operation, the temperature of the stator winding is higher than the ambient temperature.
3.1.5 Locked-rotortest
A test carried out with the motor energized and the rotor blocked in order to determine the stall torque and the stall current.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 24 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1032Test methods for three-phase asynchronous motors
- GB/T 3214Methods for measurement of capacity of pump
- GB/T 3216-2016Rotodynamic pumps -- Hydraulic performance acceptance tests -- Grades 1, 2 and 3 [including 2018XG1]
- GB/T 9651Test methods for single-phase induction motors
- GB/T 14711General requirements for safety of small and medium size rotating electrical machines
- GB/T 22719.1Interturn insulation of random-wound winding for AC low-voltage electrical machines - Part 1: Test methods
Similar standards
Editions of GB/T 26117
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 26117-2022 | Miniature electric pumps—Testing method | current edition | Current |
| GB/T 26117-2010 | Miniature electric pumps—Testing method | previous edition | Superseded |
This page sells the current edition, GB/T 26117-2022. Earlier editions are listed for reference only.
How to Download GB/T 26117-2022
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 1032-2023 — Test methods for three-phase asynchronous motors
GB/T 10320-2011 — Electrical safety of laser equipment and installatins
GB/T 10322.1-2023 — Iron ores - Sampling and sample preparation procedures
Secure payment via Stripe
Payments accepted
GB/T 26117-2022
$450.00