Scope

GB/T 20994-2007 is the English-translated version of 高压直流输电系统用并联电容器及交流滤波电容器.

GB/T 20994-2007 covers the shunt capacitors and AC filter capacitors of HVDC transmission systems.

Clause 1.1 states that the standard is suitable for the shunt capacitors and shunt capacitor banks installed on the AC side of HVDC converter stations to provide reactive power compensation, and for the AC filter capacitors and AC filter capacitor banks used to filter out AC side harmonics and provide reactive power compensation at a fundamental frequency of 50 Hz or 60 Hz, and that its purposes are to set out uniform rules on performance, testing and rating, to set out specific safety rules and to provide guidelines for installation and operation.

The contents list clause 1 General, clause 2 Quality requirements and testing, clause 3 Design and structural requirements, clause 4 Insulation level, clause 5 Overload, clause 6 Safety requirements, two clauses 7 and 8 whose headings the draft renders only as flag capacitor unit and flag capacitor banks, a clause 9 on installation and operation whose heading the draft leaves unfinished, an informative Appendix A with example wiring diagrams of the AC filters common on HVDC transmission lines, and an informative Appendix B with the equations for calculating the capacitor discharge resistor and the discharge time.

Clause 1 itself holds the scope and purpose at 1.1, the normative references at 1.2 and the terms and definitions at 1.3, and clause 1.2 cites GB/T 11024.1, GB/T 11024.2, GB/T 11024.4, GB/T 13540 and GB/T 16927.1.

Clause 1.3 carries four definitions whose term names the draft does not print: a member made up of a dielectric and spaced electrodes; an assembly of one or more capacitor elements in a single housing with a lead terminal; a capacitor whose units are all connected in parallel; and an assembly of one or more series sections mounted on a support frame together with insulators and cable.

The draft breaks off at the end of that clause, so the page shows no text from clauses 2 to 9.

The introduction places the standard in a programme of nineteen national standards developed for HVDC transmission system equipment, covering basic standards, equipment standards and control and protection equipment standards, and lists it as the one on shunt capacitors and AC filter capacitors for HVDC systems.

The foreword records that the standard was proposed by the China Electrical Equipment Industrial Association, that it is administered by SAC/TC45 and that this is its first release, so it replaces no earlier edition; it was issued on 21 June 2007 and has applied since 1 February 2008.

Found what you need?

Document preview — GB/T 20994-2007

National Standard of the People's Republic of China

ICS
31.060.70
Classification
K 42

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Preface
  • Introduction
  • 1 General
  • 2 Quality requirements and testing
  • 3 Design and structural requirements
  • 4 insulation level
  • 5 Overload
  • 6 Safety requirements
  • 9 for installation and operation are
  • Appendix A (informative) HVDC transmission line common AC filter wiring diagram Example Calculate capacitor discharge resistor and discharge time of Annex B (informative) Equation

Foreword

The Standard Appendix A and Appendix B are informative.

The standard proposed by China Electrical Equipment Industrial Association.

This standard by the National Standardization Technical Committee on Power capacitor (SAC/TC45) centralized.

This standard is the first release.

Introduction

HVDC in China's power grid construction, power transmission for long distance and large-area networking has a very broad prospects for development, as is currently the In order to solve the high-voltage, large-capacity, long-distance power transmission and important means of asynchronous networking. According to China's direct DC transmission engineering requirements and high pressure Project stream transmission technology trends undertaken in the digestion and absorption of imported technology, the domestic HVDC project construction experience and independent research equipment Based on the research to develop national standards for HVDC transmission system equipment. Including basic standards, equipment standards and master control and protection equipment standard. Projects have been completed or are ongoing to develop a total of 19 national standards.

(1) "performance of the first part of the steady-state performance HVDC system"

(2) "Performance of HVDC systems failures second part of the operation."

(3) "The third part of the performance of HVDC system dynamic performance."

(4) "HVDC converter station insulation coordination procedures"

(5) "HVDC converter station losses OK"

(6) "Transformers for the second part of HVDC converter transformers"

(7) "with oil - immersed HVDC converter transformer technical parameters and requirements"

(8) "HVDC oil - immersed smoothing reactors"

(9) "HVDC oil - immersed smoothing reactors and technical requirements."

(10) "HVDC converter station gapless metal oxide surge arresters Guidelines"

(11) "HVDC systems with parallel capacitors and the AC filter capacitor"

(12) "HVDC systems with DC smoothing capacitor"

(13) "General requirements for HVDC thyristor with ordinary"

(14) "transmission and distribution systems power electronics static var compensator device thyristor valve test"

(15) "HVDC system control and protection equipment"

(16) "HVDC converter station noise"

(17) "HVDC bushing technical performance and test methods"

(18) "General requirements for HVDC light control thyristor"

(19) "DC system complete sets of equipment research and Guidelines"

1 General

1.1 Scope and purpose

This standard is suitable for installation in HVDC converter stations AC side, for providing reactive power compensation of shunt capacitors and shunt capacitor Groups and used to filter out AC side harmonics and provide reactive power compensation at the fundamental frequency of 50Hz or 60Hz AC filter capacitor and filter exchange Wave capacitor bank. The purpose of this standard are.

a) set forth uniform rules regarding performance, testing and rating of;

b) set forth the specific safety rules;

c) provide guidelines for installation and operation.

1.2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard. However, according to research encourages the parties to the agreement Study whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.

GB/T 11024.1 rated voltage above 1kV shunt capacitors for ac power systems - Part 1: General - Performance, testing and Safety requirements for fixed installation and operation guidelines (GB/T 11024.1-2001, IEC 60871-1:1997, MOD)

GB/T 11024.2 rated voltage above 1kV shunt capacitors for ac power systems - Part 2: Endurance testing (GB/T 11024.2-2001, idt IEC 60871-2:1999)

GB/T 11024.4 rated voltage above 1kV shunt capacitors for ac power systems - Part 4: Internal fuses (GB/T 11024.4-2001, idt IEC 60871-4:1996)

GB/T 13540 high-voltage switchgear earthquake resistance performance test

GB/T 16927.1 High-voltage test techniques Part 1: General test requirements (GB/T 16927.1-1997, eqv IEC 60060-1. 1989)

1.3 Terms and Definitions

This standard uses the following terms and definitions.

1.3.1 It is a dielectric and spaced electrodes composed of members

1.3.2 By one or more capacitor elements assembled in a single housing and a lead terminal of the assembly.

1.3.3 All units are connected in parallel with a capacitor

1.3.4 And by the support frame is mounted on one or more series segments, insulators, cable capacitor constituted assembly.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 22 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 20994-2007

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
22 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 20994-2007

$375.00