GB/T 18134.1-2000High-voltage test techniques - Very-fast-front overvoltage measurements (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (22 pages)

Need quotation for your management?

Get a formal quotation for GB/T 18134.1-2000 in 30 minutes.

Issued by

State Administration for Market Regulation

Level / Type

National · Recommended

Issue date

October 5, 2025

Implementation date

May 1, 2026

Scope

GB/T 18134.1-2000 (High-voltage test techniques - Very-fast-front overvoltage measurements) is available as an English-translated PDF.

GB/T 18134.1-2000 — This document describes the characteristics of ultrafast wavefront overvoltages and common measurement methods for ultrafast wavefront overvoltages, and specifies the basic requirements of the measurement system.

Requirements, transmission characteristics, and verification procedures. This document applies to the measurement of ultrafast wavefront overcurrents in gas-insulated, metal-enclosed switchgear caused by operational or internal destructive discharges.

Voltage, especially the following three types of ultra-fast wavefront overvoltage measurement systems. ---Internal ultra-fast wavefront overvoltage; ---Transient case voltage; ---External express wavefront overvoltage.

Found what you need?

Document preview — GB/T 18134.1-2000

National Standard of the People's Republic of China

ICS
19.080
Classification
K 40
Replacing
GB/T 18134.1-2000

Issued by: State Administration for Market Regulation

Contents

  • Preface
  • 1 Scope
  • 2 Normative References
  • 3 Terms and Definitions
  • 4 Characteristics of ultra-fast wavefront overvoltage
  • 4.1 Overview
  • 4.2 Characteristics of Internal Ultra-Fast Wavefront Overvoltage
  • 4.3 Characteristics of transient casing voltage
  • 4.4 Characteristics of External Fast Wavefront Overvoltage
  • 5 Measurement system for ultra-fast wavefront overvoltage
  • 5.1 General Rules
  • 5.2 Measurement methods and basic requirements of the measurement system
  • 5.2.1 Measurement Methods
  • 5.2.2 Basic Requirements
  • 5.3 Transmission Characteristics of the Measurement System
  • 5.3.1 Transfer characteristics of the measurement system for internal ultra-fast wavefront overvoltage
  • 5.3.2 Transfer characteristics of a measurement system for transient enclosure voltage
  • 5.3.3 Transfer characteristics of the measurement system for external ultra-fast wavefront overvoltage
  • 5.3.4 Determination of the transmission characteristics of the measurement system
  • 5.4 Verification Procedure for the Measurement System
  • 5.4.1 Verification Procedure for the Internal Fast Wavefront Overvoltage Measurement System
  • 5.4.2 Verification procedure for transient enclosure voltage measurement system
  • 5.4.3 Verification Procedure for External Fast Wavefront Overvoltage Measurement System
  • Appendix A (Informative) Explanation of the characteristics of ultra-fast wavefront overvoltage
  • A.1 Main components of ultra-fast wavefront overvoltage
  • A.1.1 Main components of internal ultra-fast wavefront overvoltage
  • A.1.2 Main Components of Transient Casing Voltage
  • A.1.3 Main Components of External Fast Wavefront Overvoltage
  • A.2 Generation of Transient Shell Voltage (TEV) and External Fast Wavefront Overvoltage
  • Appendix B (Informative) Estimation of Uncertainty in Measurement of Peak Value of Fast Wavefront Overvoltage
  • B.1 Sources of Measurement Uncertainty
  • B.1.1 Sources of uncertainty in the measurement of peak value of internal ultra-fast wavefront overvoltage
  • B.1.2 Sources of measurement uncertainty for transient casing voltage peak value
  • B.1.3 Sources of uncertainty in the measurement of peak value of external ultra-fast wavefront overvoltage
  • B.2 Simplified Procedure for Estimating the Measurement Uncertainty of Peak Value of Fast Wavefront Overvoltage
  • B.2.1 Simplified procedure for estimating the measurement uncertainty of the peak value of the internal ultra-fast wavefront overvoltage
  • B.2.2 Simplified procedure for estimating the measurement uncertainty of transient case voltage peak
  • B.2.3 Simplified procedure for estimating the measurement uncertainty of peak external fast wavefront overvoltage

Foreword

This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents".

Drafting.

This document replaces GB/T 18134.1-2000 "Extremely Fast Impulse High Voltage Testing Techniques - Part 1: Gas-Insulated Substations with Steep Voltages".

The main technical changes in "Measurement System for Wavefront Overvoltage" compared to GB/T 18134.1-2000, apart from structural adjustments and editorial modifications, are as follows.

as follows.

a) The wording of "range" has been changed, and the limitation on the time parameter range has been removed (see Chapter 1, Chapter 1 of the 2000 edition);

(b) The terms and definitions defined in GB/T 2900.19-2022 and GB/T 2900.20-2016 are added to apply to this document (see section [number]).

Chapter 3);

c) Change "Definitions" to "Terms and Definitions," and incorporate the revised content from the 2000 edition, adding "Transmission Characteristics" and...

The terms "rise time" and their definitions are in Chapter 3 (Chapter 3, 2000 edition).

d) A chapter on "Characteristics of Ultra-Fast Wavefront Overvoltages" has been added, and relevant content from the 2000 edition has been revised and incorporated (see Chapter 4, 2000).

Versions 4.1, 5.1, and 6.1);

e) The characteristics of the internal ultrafast wavefront overvoltage have been modified, changing the low-frequency range f3 component (0.1MHz~5MHz) to the frequency range f3.

The system operating voltage component (10Hz~55Hz) was added (see 4.2, 4.1 in the 2000 edition);

f) The characteristics of the transient casing voltage were modified, changing the VHF range f1 component (up to 100MHz) to the frequency range f1 component.

The quantity (up to 50MHz) will be adjusted to change the low-frequency range f3 component (0.1MHz~1MHz) to the frequency range f3 component.

(30kHz~1MHz), the amplitude range is modified to 0.01~0.035 times the system's highest operating voltage (see 4.3, 2000 edition).

g) The characteristics of the external ultrafast wavefront overvoltage were modified, changing the low-frequency range f3 component (0.1MHz~5MHz) to the frequency range f3.

The system operating voltage component (10Hz~55Hz) has been added, while the step voltage and very high voltage components have been removed.

The frequency range f1 component (up to 100MHz) was adjusted, and the amplitude range was modified to 1.0 to 2.0 times the system's highest operating voltage (see...).

4.4 (6.1 in the 2000 edition)

h) A chapter on "Measurement System for Ultra-Fast Wavefront Overvoltage" has been added, and relevant content from the 2000 edition has been revised and incorporated (see...).

Chapter 5 (sections 4.2, 4.3, 4.4, 5.2, 5.3, 5.4, 6.2, 6.3, and 6.4 of the 2000 edition).

i) An example of a measurement system for external ultra-fast wavefront overvoltage has been added (see Figures 7-9 in 5.2.1.3);

j) The basic requirements for the measurement system for internal ultra-fast wavefront overvoltage have been increased, with the axial distance between the conversion device and the measured point preferably being 1m.

For requirements within the scope, a new normative reference, GB/T 1985-2023, is added (see 5.2.2.1);

k) The electric field probe scheme in the feasible scheme of the transient casing voltage measurement system has been removed (see 5.3.1 in the 2000 edition);

l) The transfer characteristics of the internal ultrafast wavefront overvoltage measurement system were modified (see 5.3.1, 4.2.3 of the 2000 edition);

m) The transfer characteristics of the measurement system for transient case voltage have been modified (see 5.3.2, 5.2.3 in the 2000 edition);

n) The transfer characteristics of the measurement system for external ultra-fast wavefront overvoltage were modified (see 5.3.3, 6.2.3 of the 2000 edition);

o) The method for determining the transfer characteristics of the measurement system has been changed (see 5.3.4, 4.4.2, 5.4.2 and 6.4.2 in the 2000 edition);

p) The calibration procedure for the internal express wavefront overvoltage measurement system has been modified, and the normative reference GB/T 16927.1 has been added.

And GB/T 16927.2 (see 5.4.1, 4.4.3 of the 2000 edition);

q) The calibration procedure for the transient enclosure voltage measurement system has been modified, and the normative references GB/T 16927.1 and have been added.

GB/T 16927.2 (see 5.4.2, 5.4.3 of the 2000 edition);

r) The calibration procedure for the external express wavefront overvoltage measurement system has been modified, and the normative reference GB/T 16927.1 has been added.

And GB/T 16927.2 (see 5.4.3, 6.4.3 of the 2000 edition);

s) Added "Appendix D (Normative) Method for determining the frequency characteristics of a measurement system based on time-domain characteristics experiment".

Please note that some content in this document may involve patents. The issuing organization of this document assumes no responsibility for identifying patents.

This document was proposed by the China Electrical Equipment Industry Association.

This document is under the jurisdiction of the National Technical Committee on Standardization of High Voltage Testing Technology and Insulation Coordination (SAC/TC163).

1 Scope

This document describes the characteristics of ultrafast wavefront overvoltages and common measurement methods for ultrafast wavefront overvoltages, and specifies the basic requirements of the measurement system.

Requirements, transmission characteristics, and verification procedures.

This document applies to the measurement of ultrafast wavefront overcurrents in gas-insulated, metal-enclosed switchgear caused by operational or internal destructive discharges.

Voltage, especially the following three types of ultra-fast wavefront overvoltage measurement systems.

---Internal ultra-fast wavefront overvoltage;

---Transient case voltage;

---External express wavefront overvoltage.

2 Normative references

The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are not included.

For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies.

This document.

GB/T 1985-2023 High-voltage AC disconnect switches and grounding switches GB/T 2900.19-2022 Electrical Engineering Terminology. High Voltage Testing Techniques and Insulation Coordination GB/T 2900.20-2016 Electrical Terminology. High Voltage Switchgear and Controlgear GB/T 16927.1 High Voltage Testing Techniques – Part 1: General Definitions and Test Requirements GB/T 16927.2 High Voltage Testing Techniques – Part 2: Measurement Systems

3 Terms and Definitions

The terms and definitions defined in GB/T 2900.19-2022 and GB/T 2900.20-2016, as well as the following terms and definitions, apply to this document.

Internal ultra-fast wavefront overvoltage Ultra-fast wavefront overvoltages occur between the high-voltage conductor and the enclosure inside gas-insulated metal-enclosed switchgear (GIS).

Transient casing voltage Ultra-fast wavefront overvoltages occur between the GIS shell and the ground outside the GIS.

External ultra-fast wavefront overvoltage Extremely fast wavefront overvoltages appearing on GIS external conductors and equipment.

Transmission characteristics the functional relationship between the output and input of the measurement system.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 22 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 18134.1-2000

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
22 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 18134.1-2000

$574.00