Valid

GB/T 18039.4-2017Electromagnetic compatibility -- Environment -- Compatibility levels in industrial plants for low-frequency conducted disturbances (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (22 pages)

Need quotation for your management?

Get a formal quotation for GB/T 18039.4-2017 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China

Level / Type

National · Recommended

Issue date

December 29, 2017

Implementation date

July 1, 2018

Scope

GB/T 18039.4-2017 (Electromagnetic compatibility -- Environment -- Compatibility levels in industrial plants for low-frequency conducted disturbances) is available as an English-translated PDF.

GB/T 18039.4-2017 - This Part of GB/T 18039 is concerned with conducted disturbances in the frequency range from

Found what you need?

Document preview — GB/T 18039.4-2017

National Standard of the People's Republic of China

ICS
33.100.10; 33.100.20
Classification
L 06

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China

Contents

  • Foreword...3
  • 1 Scope...6
  • 2 Normative References...7
  • 3 Terms and Definitions...7
  • 3.1 General Definitions...8
  • 3.2 Phenomena-related Definitions...9
  • 4 Electromagnetic Environment Classes...12
  • 5 Compatibility Levels...13
  • 5.1 General Comment...13
  • 5.2 Voltage Deviations...14
  • 5.3 Voltage Dips and Short Interruptions...14
  • 5.4 Voltage Unbalance (imbalance)...14
  • 5.5 Temporary Power-frequency Variation...15
  • 5.6 Harmonics...15
  • 5.7 Interharmonics...16
  • 5.8 Voltage Components at Higher Frequencies (above 50th harmonic)...17
  • 5.9 Transient Overvoltages...17
  • 5.10 DC Component...17
  • 6 Compatibility Levels...17
  • Appendix A (informative) Explanations and Examples for Interharmonics...21
  • A.1 Resolution of Non-sinusoidal Voltages and Currents...21
  • A.2 Time Varying Phenomena...22
  • A.3 Definition of Additional Terms...22

Foreword

Electromagnetic Compatibility - Environment currently consists of the following parts:

---GB/Z 18039.1 Electromagnetic Compatibility - Environment - Classification of

Electromagnetic Environments

---GB/Z 18039.2 Electromagnetic Compatibility - Environment - Assessment of the

Emission Levels in the Power Supply of Industrial Plants as regards Low-frequency

Conducted Disturbances

---GB/T 18039.3 Electromagnetic Compatibility - Environment - Compatibility Levels for

Low-frequency Conducted Disturbances and Signaling in Public Low-voltage Power

Supply Systems

---GB/T 18039.4 Electromagnetic Compatibility - Environment - Compatibility Levels in

Industrial Plants for Low-frequency Conducted Disturbances

---GB/Z 18039.5 Electromagnetic Compatibility - Environment - Electromagnetic

Environment for Low-frequency Conducted Disturbances and Signaling in Public

Power Supply Systems

---GB/Z 18039.6 Electromagnetic Compatibility - Environment - Low Frequency

Magnetic Fields in Various Environments

---GB/Z 18039.7 Electromagnetic Compatibility - Environment - Voltage Dips and Short

Interruptions on Public Electric Power Supply Systems with Statistical Measurement

Results

---GB/T 18039.8 Electromagnetic Compatibility - Environment - Description of HEMP

Environment - Conducted Disturbance

---GB/T 18039.9 Electromagnetic Compatibility - Environment - Compatibility Levels for

Low-frequency Conducted Disturbances and Signaling in Public Medium-voltage

Power Supply Systems

This is Part 4 of Electromagnetic Compatibility - Environment.

This Part was drafted in accordance with the rules provided in GB/T 1.1-2009.

This Part serves as a replacement of GB/T 18039.4-2003 Electromagnetic Compatibility -

Environment - Compatibility Levels in Industrial Plants for Low-frequency Conducted

Disturbances.

In comparison with GB/T 18039.4-2003, the main technical changes are as follows:

---The references to IEC 60050-101, IEC 60050-551 and IEC 61000-2-12 are added (see

Chapter 2);

---The definition of "total disturbance level" is deleted; the definitions of "electromagnetic

disturbance", "disturbance level", "planning level", "fundamental frequency",

"fundamental component", "harmonic frequency", "harmonic component",

"interharmonic frequency", "inter-harmonic component", "total harmonic distortion",

"voltage unbalance", "voltage deviation", "voltage dip" and "transient overvoltage" are

added (see Chapter 3);

---The relevant description of electromagnetic environment classification is modified (see

Chapter 4);

---In terms of compatibility levels, the general description, and the description of

compatibility levels regarding voltage deviation, voltage unbalance, power-frequency

variation, harmonics and inter-harmonics are modified; the description of compatibility

levels regarding voltage components at higher frequencies, transient overvoltage and

d.c. component is added (see Chapter 5);

---The illustration of interharmonic compatibility levels is added (see Figure 1 of Chapter

6);

---The explanations and examples for interharmonics are added (see Appendix A);

---The production and mitigation methods for interharmonics and voltage components at

higher frequencies are added (see Appendix C).

This Part uses the translation method in the equivalent adoption of IEC 61000-2-4:2002

Electromagnetic Compatibility (EMC) - Part 2-4: Environment - Compatibility Levels in

Industrial Plants for Low-frequency Conducted Disturbances.

The Chinese documents that have consistent correspondence with the international documents

normatively cited in this Part are as follows:

---GB/T 4365-2003 Electrotechnical Terminology - Electromagnetic Compatibility (IEC

60050(161):1990, IDT)

---GB/T 18039.3-2017 Electromagnetic Compatibility - Environment - Compatibility

Levels for Low-frequency Conducted Disturbances and Signaling in Public Low-

voltage Power Supply Systems (IEC 61000-2-2:1990, IDT)

---GB/T 18039.9-2013 Electromagnetic Compatibility - Environment - Compatibility

Levels for Low-frequency Conducted Disturbances and Signaling in Public Medium-

voltage Power Supply Systems (IEC 61000-2-12:2003, IDT)

Electromagnetic Compatibility - Environment -

Compatibility Levels in Industrial Plants for Low-frequency

Conducted Disturbances

1 Scope

This Part of GB/T 18039 is concerned with conducted disturbances in the frequency range from

0 kHz to 9 kHz. It gives numerical compatibility levels for industrial and non-public power

distribution systems.

This Part is applicable to AC 50 Hz low-voltage and medium-voltage power supply systems.

Power supply systems on ships, aircraft, offshore platforms and railways are not included.

The compatibility levels specified in this Part apply at the in-plant point of coupling (IPC). At

the power input terminals of equipment receiving its supply from the above systems, the

severity levels of the disturbances can, for the most part, be taken to be the same as the levels

at the in-plant point of coupling. In some situations, this is not so, particularly in the case of a

long feeder dedicated to the supply of a particular load, or in the case of a disturbance generated

or amplified within the installation of which the equipment forms a part.

Compatibility levels are specified for electromagnetic disturbances of the types which can be

expected at any in-plant point of coupling (IPC) within industrial plants or other non-public

networks, for guidance in

a) limits to be set for disturbance emission into industrial power supply systems

(including the planning levels defined in 3.1.5);

NOTE 1 A very wide range of conditions is possible in the electromagnetic environments of

industrial and other non-public networks. These are approximated in this Part by the three

classes described in Chapter 4. However, it is the responsibility of the operator of such a

network to take account of the particular electromagnetic and economic conditions,

including equipment characteristics, in setting the above-mentioned limits.

b) the choice of immunity levels for the equipment within these systems.

The disturbance phenomena considered are:

– voltage deviations;

– voltage dips and short interruptions;

– voltage unbalance;

– power-frequency variations;

NOTE 3 Electronic converters produce characteristic harmonic orders due to their topology when

used under their rated operating conditions. Different operating conditions such as

unbalance, non-ideal commutation instants, etc. may cause other harmonic orders to be

produced.

The voltage unbalance caused by a single-phase load connected line-to-line is in practice equal

to the ratio of the load power to the network three-phase short circuit power. If no substantial

single-phase load is present, the compatibility levels of class 2 may be applied.

5.5 Temporary Power-frequency Variation

The compatibility levels of power-frequency deviations of the public network apply to

industrial plants fed from the public power supply.

For the most part, the range is within 1 Hz of the nominal frequency as stated in 4.8 of IEC

61000-2-2. Where synchronous interconnection is implemented on a continental scale, the

variation is usually very much less.

The compatibility level for the temporary variation of frequency from the nominal frequency is

± 1 Hz. The steady-state deviation of frequency from the nominal frequency is much less.

NOTE 1 For some equipment the rate of change of frequency is significant.

NOTE 2 In the case of supply systems isolated from the public network, frequency variations up to

± 4% are expected. The actual compatibility levels in this instance are to be agreed upon.

5.6 Harmonics

The compatibility levels for individual harmonic components of the voltage shall be understood

to relate to quasi-stationary or steady-state harmonics and are given as reference values for both

long-term effects and very short-term effects.

The long-term effects relate mainly to thermal effects on cables, transformers, motors,

capacitors, etc. They arise from harmonic levels which are sustained for periods equal to or

higher than 10 min.

With reference to long-term effects, compatibility levels for individual harmonic components

of the voltage are given in Tables 2 to 4. The corresponding compatibility levels for the total

harmonic distortion are given in Table 5.

Very short-term effects relate mainly to disturbing effects on electronic devices that may be

susceptible to harmonic levels sustained for 3 s or less. Transients are not included.

With reference to very short-term effects in class 1 and class 3, compatibility levels for

individual harmonic components of the voltage, and for total harmonic distortion, are 1.5 times

the values given in Tables 2 to 5.

In class 2, they are the values given in Tables 2 to 4 multiplied by a factor k, where k is as

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 22 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 18039.4-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
22 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 18039.4-2017

$415.00