GB/T 32877-2022Specific test methods for determining losses and efficiency of converter-fed AC motors (English PDF)
Also coversGBT32877-2022
Open the GB/T 32877-2022 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
October 14, 2022
Implementation date
May 1, 2023
Scope
GB/T 32877-2022 (Specific test methods for determining losses and efficiency of converter-fed AC motors) is available as an English-translated PDF.
GB/T 32877-2022 — This document outlines the test methods and plug-in for determining losses and efficiency of motors within the scope of GB/T 755-2019 when powered by frequency converters. Value procedure, the motor is also part of the speed-regulated electrical drive system (PDS) defined in GB/T 12668.902-2021. Motor efficiencies determined using the comparative frequency converter method of this document are used only to compare different motor designs. This document also gives the determination of the motor in the reference speed range (constant torque range, constant magnetic flux range) based on seven standard load point losses. The program of loss of any load point (torque, speed), this program is suitable for the frequency conversion and voltage regulation according to GB/T 755-2019. Source powered any speed regulated AC motor (induction and synchronous).
Document preview — GB/T 32877-2022
National Standard of the People's Republic of China
- ICS
- 29.160.30
- Classification
- K 22
- Replacing
- GB/T 32877-2016
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- foreword
- 60 is converted into revolutions per second, so the original formula Tref=
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules of Standardization Documents"
drafted.
This document replaces GB/T 32877-2016 "Specific test methods for determining loss and efficiency of AC induction motors powered by frequency converters",
Compared with GB/T 32877-2016, except for structural adjustment and editorial changes, the main technical changes are as follows.
a) change the term "harmonic loss" to "additional high frequency loss" (see 3.3, 3.3 of the.2016 edition);
b) deleted 2-3-D calorimetry (see 6.5 of the.2016 edition);
c) Added the substitution efficiency determination method (AEDM method) (see 6.4);
d) The calculation method is added to determine the efficiency (see 6.5);
e) added the loss of any operating point by interpolation (see Chapter 7);
f) Deleted Appendix A "Definition of Output Voltage of Inverter for Test" (see Appendix A of the.2016 edition);
g) Added Appendix A "Loss of AC Motor" (see Appendix A);
h) Added Appendix B "Examples for Determining Loss and Efficiency at Each Load Point" (see Appendix B).
This document is equivalent to IEC 60034-2-3.2020 "Rotating electrical machines Part 2-3.Determination of losses and
Specific Test Methods for Efficiency".
The following minimal editorial changes have been made to this document.
--- In order to harmonize with existing standards, the name of the standard has been changed to "Specific tests for determining losses and efficiency of AC motors powered by frequency converters"
method";
--- Corrected the error of the switching frequency in 5.2.4, according to the provisions of 5.2.2, the switching frequency in 5.2.4 was changed from 4kHz or 4kHz in the original text.
8kHz corrected to 5kHz or 10kHz;
--- Corrected the typo in the original text in formula (1). The speed unit defined in this document is revolutions per minute, which needs to be divided by
60 is converted into revolutions per second, so the original formula P2C=2pi.TC.n is corrected to P2C=2pi.TC.n/60;
--- Corrected the typo in the original text in formula (5). The speed unit defined in this document is revolutions per minute, which needs to be divided by
60 is converted into revolutions per second, so the original formula Tref=
Pref
2pi.nref
Corrected to Tref=
Pref
2pi.nref/60
---All formulas are supplemented with serial numbers.
Please note that some content of this document may be patented. The issuing agency of this document assumes no responsibility for identifying patents.
Introduction
The purpose of this document is to define a test method for determining the total loss and efficiency of frequency converter powered motors, the total loss including the additional high frequency
loss. The additional high frequency loss is obviously a standard sine wave power supply, and the loss determined according to the test method of GB/T 25442-2018 is less than
outside. The results from this document will be used to compare losses and efficiencies of different motors when powered by frequency converters.
In addition, this document defines seven standard operating points to describe extended characteristics of losses and efficiencies covering the entire torque/speed range, providing
An interpolation calculation program is provided to determine losses and efficiencies at any operating point (torque, speed).
In an electrical drive system (PDS), the electric motor and frequency converter are usually supplied by different manufacturers. Motors of the same design are used in large quantities
Production, may be driven by the grid or different types of inverters provided by different manufacturers, the respective performance of the inverters (such as switching frequency,
DC bus voltage level, etc.) will also affect the efficiency of the system, for each motor, frequency converter, connecting cable, output filter and parameter settings
It is impractical to determine the motor losses for the combination of motor losses, this document describes a limited number of
a method.
The losses determined in accordance with this document do not represent losses in actual use, but are used to compare whether different motor designs are suitable for frequency converter operation.
provide objective evidence.
Usually, the motor losses when powered by a frequency converter are higher than when operating in a standard sine wave system, the additional high frequency losses depend on the external frequency converter
The frequency spectrum (voltage or current) of the output quantity, which is affected by the inverter circuit and control method, see GB/T 21209-2017 for more information.
Compare drives
The latest empirical and theoretical analysis shows that the additional high-frequency losses generally do not increase with load, and most of the methods described in this document are based on pulse
Powered by a Pulse Width Modulated (PWM) frequency converter.
Given the wide variety of these drives and the growing need to verify compliance with national energy efficiency regulations, this document defines a so-called
Comparison frequency converters are used to test low voltage motors.
In principle, the comparative inverter is a voltage source with typical high frequency harmonics supplying the motor under test, which is not suitable for medium voltage motors.
Comparing the limitations of frequency converter applications
It should be noted that the test method described in this document for the application of comparative frequency converters is a standardized method and is intended for use with standard test strips.
Comparable efficiency values are provided under conditions. Through this method, the matching of the operation of the motor and the frequency converter can be obtained, but it does not mean that it is determined.
Actual losses of a motor powered by a specific frequency converter, which requires testing the entire electrical drive system powered by the end application specific frequency converter
(PDS).
Compared with the two-level voltage source inverter, when the multi-level voltage source or current source inverter drives the motor, the additional high frequency loss depends more on the
It depends on the speed and load, therefore, when determining the loss and efficiency, it is preferred to use the same frequency converter in practical application to test together with the motor.
Another option is to determine the additional high frequency losses of the motor by calculation. If this is a customer requirement, the pulse mode of the inverter is required.
This document does not cover this part of the program.
Provided interpolation routines to determine losses and efficiencies at any operating point (torque, speed), limited to the reference speed range (constant torque range).
range, constant magnetic flux range).
Inverter powered AC motors determine losses and
Specific Test Methods for Efficiency
1 Scope
This document outlines the test methods and plug-in for determining losses and efficiency of motors within the scope of GB/T 755-2019 when powered by frequency converters.
Value procedure, the motor is also part of the speed-regulated electrical drive system (PDS) defined in GB/T 12668.902-2021.
Motor efficiencies determined using the comparative frequency converter method of this document are used only to compare different motor designs.
This document also gives the determination of the motor in the reference speed range (constant torque range, constant magnetic flux range) based on seven standard load point losses.
The program of loss of any load point (torque, speed), this program is suitable for the frequency conversion and voltage regulation according to GB/T 755-2019.
Source powered any speed regulated AC motor (induction and synchronous).
2 Normative references
The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations
documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to
this document.
GB/T 755-2019 Rating and performance of rotating electrical machines (IEC 60034-1.2017, IDT)
GB/T 12668.902-2021 Speed-regulating electrical drive system Part 9-2.Electric drive system, motor starter, power electronics
Eco-design of equipment and drive applications Energy efficiency indicators for electrical drive systems and motor starters (IEC 61800-9-2.2017, IDT)
GB/T 18039.4-2017 Compatibility Level of Low-Frequency Conducted Disturbance in Factory for Electromagnetic Compatibility Environment (IEC 61000-2-4.2002,
IDT)
GB/T 25442-2018 Test methods for determining losses and efficiency of rotating electrical machines (except traction motors) (IEC 60034-2-1.2014,
IDT)
3 Terms and Definitions
The terms and definitions defined in GB/T 755-2019, GB/T 25442-2018 and the following apply to this document.
ISO and IEC maintain terminology databases for standardization at.
3.1
When the inverter is powered, the loss of the motor is composed of the loss caused by the fundamental frequency and the loss caused by the high frequency of the inverter.
3.2
Fundamental loss fundamentallosses
The fundamental wave loss of the motor can be divided into 5 parts. iron loss (varies with motor frequency and fundamental power supply voltage), wind wear (varies with motor frequency and power supply voltage)
Motor speed change), rotor winding loss, stator winding loss and load stray loss (these three losses vary with motor current). Fundamental loss
The loss is the loss when the motor is running at the rated voltage supply at the fundamental frequency without any other high frequency.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
GB/T 755-2019 · IEC 60034 · GB/T 12668.902-2021 · IEC 61800 · GB/T 18039.4-2017 · IEC 61000 · GB/T 25442-2018
How to Buy GB/T 32877-2022
- 1Add to cart. Click the "Buy GB/T 32877-2022" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 46830.2-2026 — Plastics - Liquid crystal polymer (LCP) moulding and extrusion materials - Part 2: Preparation of test specimens and determination of properties
GB/T 28593-2026 — Sand and dust weather warning levels
GB/T 19608.3-2026 — Classification of special environmental conditions - Part 3: Plateau
Secure payment via Stripe
Payments accepted
GB/T 32877-2022
$305.00