Scope

GB/T 18039.8-2012 is the English-translated version of 电磁兼容 环境 高空核电磁脉冲(HEMP)环境描述 传导骚扰.

GB/T 18039.8-2012 — This section GB/T 18039 requirements of high-altitude nuclear electromagnetic pulse (HEMP) conducted environment, HEMP series of high-altitude nuclear explosion effect it should be one of the research topics such two cases to consider. --- High-altitude nuclear explosion; --- Low-altitude nuclear explosions.

The civil system, the two cases are among the most important high-altitude nuclear explosions.

High-altitude nuclear explosion is characterized by a shock wave, the earth shook, Thermal radiation and nuclear radiation and other effects of nuclear explosions on the ground does not exist, but the electromagnetic pulse generated by a nuclear explosion would cause communication, electricity Son and electrical systems work interruptions and damage, disrupting the stability of modern society.

The purpose of this section is to establish a common standard on HEMP environment, in order to determine the true from electromagnetic disturbance environment for Evaluate the performance of the device by the impact.

Found what you need?

Document preview — GB/T 18039.8-2012

National Standard of the People's Republic of China

ICS
33.100.01
Classification
L 06

Issued by: Standardization Administration of China

Contents

  • Preface
  • 1 Scope and purpose
  • 2 Normative references
  • 3 Subjects
  • 4 Terms and definitions
  • 5 HEMP environment description, conduction parameters
  • 5.1 Introduction
  • Early 5.2 HEMP conducted external environment
  • 5.3 External conduction mid HEMP environment
  • 5.4 Late HEMP conducted external environment
  • 5.5 Antenna Current
  • 5.6 HEMP conducted internal environment
  • Appendix A (informative) on early HEMP coupling of long discussions
  • A.1 overhead lines
  • A.2 buried ground coupling
  • A.3 References
  • Annex B (informative) on the medium-term to long-term discussion of HEMP coupling
  • B.1 overhead lines
  • B.2 buried ground
  • Response Annex C (informative) simple linear antenna IEC Early HEMP environment
  • C.1 Introduction
  • C.2 IEC Early HEMP environment
  • Calculation C.3 antenna Response

Foreword

GB/T 18039 "Electromagnetic Compatibility Environment" is divided into the following sections.

GB/Z18039.1-2000 EMC environment Classified electromagnetic environment GB/Z18039.2-2000 EMC environment power supply of industrial frequency conducted to assess the emission levels GB/T 18039.3-2003 electromagnetic compatibility environment public low-voltage power supply system is compatible with conduction disturbances and signaling Level GB/T 18039.4-2003 electromagnetic compatibility environment facility frequency conducted disturbances compatibility level GB/Z18039.5-2003 electromagnetic compatibility environment in public power supply system frequency conducted electromagnetic environment harassment and signal transmission GB/Z18039.6-2005 electromagnetic compatibility environment of low frequency magnetic fields in various environments GB/Z18039.7-2011 electromagnetic compatibility environment public power supply system voltage dips, short interruptions and measurement statistics result GB/T 18039.8-2012 electromagnetic compatibility environment altitude nuclear electromagnetic pulse (HEMP) environment described Conducted disturbance this is Part 8 GB/T 18039 in.

Rules in this section in accordance with GB/T 1.1-2009 given draft.

This section is equivalent international standard IEC 61000-2-10:1998 "Electromagnetic compatibility (EMC) - Part 2-10. Environment altitude nuclear power Magnetic pulse (HEMP) environment is conducted disturbances. " Electromagnetic Compatibility This part of the National Standardization Technical Committee (SAC/TC246) and focal points.

This section is drafted. Engineering Corps, PLA University of Technology.

1 Scope and purpose

This section GB/T 18039 requirements of high-altitude nuclear electromagnetic pulse (HEMP) conducted environment, HEMP series of high-altitude nuclear explosion effect it should be one of the research topics such two cases to consider.

--- High-altitude nuclear explosion;

--- Low-altitude nuclear explosions.

The civil system, the two cases are among the most important high-altitude nuclear explosions. High-altitude nuclear explosion is characterized by a shock wave, the earth shook, Thermal radiation and nuclear radiation and other effects of nuclear explosions on the ground does not exist, but the electromagnetic pulse generated by a nuclear explosion would cause communication, electricity Son and electrical systems work interruptions and damage, disrupting the stability of modern society.

The purpose of this section is to establish a common standard on HEMP environment, in order to determine the true from electromagnetic disturbance environment for Evaluate the performance of the device by the impact.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated edition applies to this article Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 4365-2003 electrician term electromagnetic compatibility (IEC 60050 (161).1990, IDT) IEC 61000-2-9:1996 Electromagnetic compatibility (EMC) - Part 2-9. Environmental altitude nuclear electromagnetic pulse (HEMP) environment description Said radiation harassment (Electromagneticcompatibility (EMC) -Part 2-9. DescriptionofHEMPenviroment-Radiateddisturbance) IEC 61000-4-24:1997 Electromagnetic compatibility (EMC) - Part 4-24. Testing and measurement techniques - HEMP conducted disturbance protection Test Method (Electromagneticcompatibility (EMC) -Part 4-24 means. Testingandmeasurementtech-niques-TestmethodsforprotectivedevicesforHEMPconducteddisturbance)

3 Subjects

30km above the ground from the electromagnetic pulse generated by high-altitude nuclear explosion, there is observed on the surface of the Earth in three types.

--- Early HEMP (fast);

--- Mid-HEMP (middle);

--- Late HEMP (slow).

In the past, people focus on early HEMP, referred to simply as "HEMP". As used in this section, but "high-altitude EMP" the term or "HEMP", including the above three types of nuclear electromagnetic pulse (NEMP) The term covers a variety of nuclear electromagnetic pulse, including Ground source region explosion electromagnetic pulse (SREMP-SourceRegionEMP) and system electromagnetic pulse (SGEMP- space generated SystemGeneratedEMP).

GB/T 18039.8-2012/IEC 61000-2-10:1998

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 27 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 18039.8-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
27 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 18039.8-2012

$425.00