GB/T 16294-2010Test method for settling microbe in clean room(zone) of the pharmaceutical industry (English PDF)
医药工业洁净室(区)沉降菌的测试方法
This is a limited preview
Buy now to download the full PDF (16 pages)
Need quotation for your management?
Get a formal quotation for GB/T 16294-2010 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
September 2, 2010
Implementation date
February 1, 2011
Scope
GB/T 16294-2010 is the English-translated version of 医药工业洁净室(区)沉降菌的测试方法.
GB/T 16294-2010 is the Chinese standard "Test method for settling microbe in clean room (zone) of the pharmaceutical industry". Its scope clause reads: This Standard specifies the test conditions and test method for setting microbe in clean room and clean zone of the pharmaceutical industry.
This Standard is applicable to the test of setting microbe in clean room and clean zone of the pharmaceutical industry, and in sterile room or local air purification area (including the clean bench), and the verification of the environment.
Its clauses include terms and definitions; test method; test rules. It was issued by the China Food and Drug Administration on SEPTEMBER 02, 2010 and took effect on FEBRUARY 01, 2011.
Found what you need?
Document preview — GB/T 16294-2010
National Standard of the People's Republic of China
- ICS
- 13.040.30
- Classification
- C 30
- Replacing
- GB/T 16294-1996
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative references4
- 3 Terms and definitions4
- 4 Test method5
- 5 Test rules7
- Annex A (normative) Clean room (zone) sampling point layout12
- Annex B (normative) Sterilization and preparation of culture medium14
- Annex C (informative) Technical requirements for settling microbe in clean room (zone)16
1 Scope
This Standard specifies the test conditions and test method for setting microbe in clean room and clean zone of the pharmaceutical industry.
This Standard is applicable to the test of setting microbe in clean room and clean zone of the pharmaceutical industry, and in sterile room or local air purification area (including the clean bench), and the verification of the environment.
2 Normative references
The following documents contain the provisions which, through reference in this Standard, become the provisions of this Standard. For dated references, their subsequent amendments (excluding corrigendum) or revisions do not apply to this Standard. However, the parties who enter into agreement based on this Standard are encouraged to investigate whether the latest versions of these documents are applicable. For undated reference documents, the latest versions apply to this Standard.
GB/T 16292-2010 Test method for airborne particles in clean room(zone) of the pharmaceutical industry
3 Terms and definitions
For the purpose of this Standard, the following terms and definitions apply.
3.1 Settling microbe
Visible number of colonies that are colonized using living microbial particles in the air collected by the method mentioned in this Standard, in special culture medium, under suitable growth conditions.
3.2 Settling microbe plate count
Number of setting microbe in the air that are collected in each plate petri dish in the specified period of time, expressed in cells/dish.
4 Test method
4.1 Method summary
This test method adopts the sedimentation method, that is, collect biological particles in the air on the culture medium plate through natural sedimentation principle, after some time, let it grow to visible colonies under appropriate conditions and count, determine the number of living microorganisms in a clean environment by counting the number of colonies in the plate petri dish, so as to assess the cleanliness of the clean room (zone).
4.2 Personnel responsibility and training
The test personnel of the clean room (zone) shall be trained in this specialty and obtain relevant qualifications before they can perform their duties in the clean room (zone) test, which includes hygienic knowledge and basic knowledge of the microorganisms involved.
4.3 Instruments
The instrument shall include.
4.3.1 Petri dish
It generally uses phi 90 mm × 15 mm petri dishes.
4.3.2 Culture medium
Soybean casein agar medium (TSA) or sabouraud medium (SDA) or user-approved and validated medium. The preparation method is shown in Annex B.
4.3.3 Constant temperature incubator
The constant temperature incubator must be checked regularly.
4.4 Test procedure
4.4.1 Before test, the surface of the petri dish must be strictly sterilized.
4.4.2 PLACE the prepared petri dishes one by one according to the sampling point layout, and then OPEN the lid of the petri dishes one by one from inside to outside so that the surface of the culture medium is exposed to air.
4.4.3 In the static state test, the exposure time of the petri dishes is more than 30 min; in the dynamic state test, the exposure time of the petri dishes is not more than 4 h.
4.4.4 After all sampling is complete, place the petri dishes in the constant temperature incubator.
4.4.5 The petri dish prepared by soybean casein agar medium (TSA) are sampled and cultured in the incubator at 30 °C to 35 °C for no less than 2 d.
The petri dish prepared by sabouraud medium (SDA) are sampled and cultured in the incubator at 20 °C ~ 25 °C for no less than 5 d.
4.4.6 Each batch of culture medium shall have a control test to test whether the culture medium itself is contaminated. It may select three petri dishes for control culture in each batch.
4.5 Colony count
4.5.1 Directly count and mark all the colonies on the petri dish with the naked eye or count on the colony counter, and then check with a magnifying glass 5 to 10 times for omission.
4.5.2 If there are 2 or more colonies overlapping on the plate, it will still count as 2 or more colonies when they are distinguishable.
4.6 Precautions
4.6.1 The test instruments shall be sterilized to ensure the reliability and correctness of the test.
4.6.2 Take all measures to prevent human contamination of the sample.
4.6.3 Make a detailed record of the culture medium, culture conditions and other parameters.
5 Test rules
5.1 Test conditions
Before test, the clean room (zone)-related parameters shall be pre-tested, which will provide environmental conditions for testing setting microbe. For example, the pre-test may include.
5.2 Test states
Both static and dynamic states can be tested.
In the static state test, the number of indoor testing personnel shall not be more than 2.
Before the settling microbe test, is decided by the user whether or not the clean room (zone) to be tested needs to be disinfected in advance.
The test report shall indicate the state used and the number of indoor testing personnel during the test.
5.3 Test time
5.3.1 In the empty state or static state a test, for unidirectional-flow clean rooms (zones), the test should be started after the clean air conditioning system is normally operating for not less than 10 min. For non-unidirectional-flow clean rooms (zones), the test should start after the clean air conditioning system is normally operating for not less than 30 min. In the static b test, for unidirectional-flow clean rooms (zones), the test should be started after the production operators are evacuated from the site and after 10 min self-cleaning; for non-unidirectional-flow clean rooms (zones), the test should be started after the production operators are evacuated from the site and after 20 min self-cleaning.
5.3.2 In the dynamic state test, it shall record the production start time and test time.
5.4 Calculation of settling microbe plate count
5.4.1 Number of sampling points and their layout
5.4.1.1 Minimum number of sampling points
The minimum number of sampling points for the settling microbe test may refer to GB/T 16292-2010.
5.4.1.2 Position of sampling points
The position of sampling points for setting microbe may refer to GB/T 16292-2010.
5.4.2 Minimum number of petri dishes
While satisfying the minimum number of sampling points, it should satisfy the minimum number of petri dishes, as shown in Table 1.
5.4.3 Number of sampling
Each sampling point is generally sampled once.
5.4.4 Precautions of sampling
5.4.4.1 For unidirectional-flow clean rooms (zones) or air supply ports, the sampling port of the sampler shall face the airflow direction; for non-unidirectional-flow clean rooms (zones), the sampling port shall be upward.
5.5 Records
The test report shall contain the following. […]
5.6 Result calculation
5.6.1 Count the number of colonies in each petri dish.
5.6.2 For the calculation of the average colony count of setting microbe at each test point, see equation (1).
5.7 Result evaluation
5.7.1 The average colony number of setting microbe at each test point must be lower than the limit in the selected evaluation criteria.
5.7.2 In the static state test, if the average colony number of setting microbe at a certain test point exceeds the evaluation criteria, it shall re-sample twice. It is determined qualified only when the two test results are qualified.
5.8 Daily monitoring
For monitoring of setting microbe, it should set correcting limits and warning limits, to ensure that the microbial concentration in the clean room (zone) is controlled. It shall carry out periodic test to check the microbial load and the effectiveness of the disinfectant to perform propensity analysis. Both static and dynamic monitoring can use this method.
For the sampling frequency of setting microbe, it shall be considered for modification if the following conditions occur. After evaluating the following conditions, it shall also determine the test frequency of other items.
- continuously exceeding correcting limits and warning limits;
- the duration of downtime is longer than expected;
- the presence of contamination in key areas;
- during the production, the air purification system performs any major maintenance;
Annex A (normative) Clean room (zone) sampling point layout
A.1 The clean room (zone) sampling point layout should be uniform, avoiding sampling points being too sparse in local areas. The following sampling point layout diagram of multi-point sampling may be used as reference (see Figure A.1).
A.2 The sampling points of class 100 unidirectional-flow zone, clean bench or local air purification facilities should be located on the working surface facing the direction of the air flow. The air flow pattern may refer to Figure A.2 and Figure A.3. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.
Referenced standards
Normative references
Cited by
- GB/T 43585-2023Disposable tampons
- GB/T 41124-2021General technical requirements for aseptic blowing-filling-capping blocks
- GB/T 38517-2020Particulates - Bioaerosol sampling and analysis - General principles
- YY/T 0513.1-2019Allogeneic grafts - Part 1: The basic requirements for tissue bank
- SN/T 3901-2014Code of use and management for biological safety cabinet
- JB/T 20008.2-2012Injection vials screw powder filling machine
Similar standards
Editions of GB/T 16294
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 16294-2010 | Test method for settling microbe in clean room(zone) of the pharmaceutical industry | current edition | Current |
| GB/T 16294-1996 | Test method for settling microbe in clean room(zone) of the pharmaceutical industry | previous edition | Superseded |
This page sells the current edition, GB/T 16294-2010. Earlier editions are listed for reference only.
How to Download GB/T 16294-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 16292-2010 — Test method for airborne particles in clean room(zone) of the pharmaceutical industry
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
Secure payment via Stripe
Payments accepted
GB/T 16294-2010
$135.00