Valid

GB/T 15544.2-2017Short-circuit current calculation in three-phase a.c. systems -- Part 2: Factors for the calculation of short-circuit currents (English PDF)

三相交流系统短路电流计算 第2部分:短路电流计算应用的系数

Preview PDF

This is a limited preview

Buy now to download the full PDF (53 pages)

Need quotation for your management?

Get a formal quotation for GB/T 15544.2-2017 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Level / Type

National · Recommended

Issue date

December 29, 2017

Implementation date

July 1, 2018

Scope

GB/T 15544.2-2017 is the English-translated version of 三相交流系统短路电流计算 第2部分:短路电流计算应用的系数.

GB/T 15544.2-2017 — This part of GB/T 15544.1 specifies the method for calculating the short-circuit current of a three-phase AC system by introducing various coefficients to meet the standards.

Technical accuracy and simplification requirements. This section describes the various factors introduced in GB/T 15544.1. This section is right the addition of GB/T 15544.1 does not change the standardized calculation method already specified.

Found what you need?

Document preview — GB/T 15544.2-2017

National Standard of the People's Republic of China

ICS
29.240.20
Classification
F 20

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Contents

  • Preface
  • 1 Overview
  • 1.1 Scope and Purpose
  • 1.2 Normative references
  • 1.3 Application of coefficients
  • 1.3.1 Coefficient c
  • 1.3.2 Coefficients KG and KS or KSO
  • 1.3.3 Coefficients KG.S, KT.S or KG.SO, KT.SO
  • 1.3.4 Factor KT
  • 1.3.5 Coefficient kappa
  • 1.3.6 Coefficient µ, lambda, q
  • 1.3.7 Coefficients m and n
  • 1.3.8 Influence of Asynchronous Motor on Initial Symmetrical Short Circuit Current
  • 1.4 Symbols, Lower and Upper Marks
  • 1.4.1 Symbol
  • 1.4.2 Lower Corner
  • 1.4.3 Superscript

Foreword

GB/T 15544 "Three-phase AC system short-circuit current calculation" is divided into the following five parts.

--- Part 1. Current calculations;

--- Part 2. Coefficients for short circuit current calculation applications;

--- Part 3. Electrical Equipment Data;

--- Part 4. Simultaneous occurrence of two independent single-phase ground fault currents and currents flowing through the earth;

--- Part 5. Examples.

This part is part 2 of GB/T 15544.

This section was drafted in accordance with the rules given in GB/T 1.1-2009.

This section uses the translation method equivalent to the use of IEC/T R60909-1.2002 "Three-phase AC system short-circuit current calculation Part 1. According to IEC 60909-0 Coefficients for Short-Circuit Current Calculation Applications." the Chinese documents that are consistent with the normatively cited international documents in this section are as follows.

---GB/T 156-2007 standard voltage (IEC 60038:2002, MOD);

---GB/T 15544.3-2017 Short-circuit current calculation for three-phase AC systems Part 3. Electrical equipment data (IEC TR60909-2:2008, IDT).

This section made the following editorial changes.

--- To be consistent with the existing standard series, change the name of this part to "Three-phase AC system short-circuit current calculation Part 2. Short-circuit electricity Flow Calculation Application Coefficients".

This section was proposed by the China Electricity Council.

This part is under the jurisdiction of the National Standardization Technical Committee on short-circuit current calculation (SAC/TC424).

This section drafted by. State Grid Corporation of China State Electric Power Dispatching Control Center, China Electric Power Research Institute, Xi'an Jiaotong University.

1 Overview

1.1 Scope and purpose

This part of GB/T 15544.1 specifies the method for calculating the short-circuit current of a three-phase AC system by introducing various coefficients to meet the standards.

Technical accuracy and simplification requirements. This section describes the various factors introduced in GB/T 15544.1. This section is right the addition of GB/T 15544.1 does not change the standardized calculation method already specified.

1.2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article Pieces. For undated references, the latest version (including all amendments) applies to this document.

GB/T 15544.1-2013 Three-phase AC system short-circuit current calculation Part 1. Current calculation (IEC 60909-0:2001, IDT) GB/T 15544.5-2017 Short-circuit current calculation for three-phase AC systems Part 5. Example (IEC/T R60909-4.2000, IDT) IEC 60038. 1983 IEC standandvoltages IEC/T R60909-2.1992 Electrical equipment data for short-circuit current calculation applications according to IEC 60909 (1988) [Electrical equipment-Dataforshort-circuitcurrentcalculationsinaccordancetoIEC 60909(1988)]

1.3 Application of coefficients

1.3.1 Coefficient c

The voltage coefficients cmax and cmin are used simultaneously with the equivalent voltage source at the short-circuit point to calculate the maximum and minimum initial short-circuit currents.

1.3.2 Coefficients KG and KS or KSO

The impedance correction factor KG, KS or KSO is introduced when calculating the short-circuit impedance of the generator-generator transformer group.

1.3.3 Coefficients KG.S, KT.S or KG.SO, KT.SO

Short circuit between generator and unit transformer (with or without load adjustment taps), impedance correction system when calculating local short-circuit current Number KG.S, KT.S or KG.SO, KT.SO.

1.3.4 Factor KT

The impedance correction factor KT is introduced when calculating the short-circuit impedance of the grid transformer.

1.3.5 Coefficient kappa

The peak short-circuit current is calculated using the factor kappa.

1.3.6 Coefficient µ, lambda, q

Calculate the coefficient used when the AC component of the short-circuit current near the generator or near the induction motor decays.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 53 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 15544.2-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
53 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 15544.2-2017