GB/T 15544.3-2017Short-circuit current calculation in three-phase a.c. systems -- Part 3: Data of electrical equipment (English PDF)

三相交流系统短路电流计算 第3部分:电气设备数据

Preview PDF

This is a limited preview

Buy now to download the full PDF (31 pages)

Need quotation for your management?

Get a formal quotation for GB/T 15544.3-2017 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Level / Type

National · Recommended

Issue date

December 29, 2017

Implementation date

July 1, 2018

Scope

GB/T 15544.3-2017 is the English-translated version of 三相交流系统短路电流计算 第3部分:电气设备数据.

GB/T 15544.3-2017 — This part of GB/T 15544 covers electrical equipment collected from different countries data, if necessary, can be used in accordance with GB/T 15544.1 into Short circuit current calculation.

The data for electrical equipment is usually provided by the manufacturer as a nameplate parameter or by the power supplier. In some cases, these data may not be available.

When the data given in this section consistent with the typical equipment of the user's country Then these data can be used to calculate the short-circuit current of the LV grid.

This section collects data and its evaluation can be applied to medium pressure or high pressure the grid plan can also be used as a comparison with the equipment data provided by the equipment manufacturer or power supplier.

For overhead lines and cables, somewhere in these cases, the electrical parameters can be calculated from the dimensions provided in this document based on their dimensions.

This section as a supplement to GB/T 15544.1, does not change the GB/T 15544.1 and GB/T 15544.4 gives standardized calculation Process.

Found what you need?

Document preview — GB/T 15544.3-2017

National Standard of the People's Republic of China

ICS
29.240.20
Classification
F 20

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Contents

  • Preface
  • 1 Overview
  • 1.1 Scope and objectives
  • 1.2 Normative references
  • 2 Electrical Equipment Data
  • 2.1 Overview
  • 2.2 Typical data synchronous motor
  • 2.3 Double winding, three winding and autotransformer typical data
  • 2.4 Typical single-loop double-circuit line with the same frame frame
  • 2.5 Typical high voltage, medium voltage and low voltage cable parameters
  • 2.6 Induction motor parameters
  • 2.7 Bus
  • Appendix A (Informative) National Committee Information
  • References

Foreword

GB/T 15544 "three-phase AC system short-circuit current calculation" is divided into the following five sections.

--- Part 1. Current calculation;

--- Part 2. Short circuit current calculation and application of the coefficient;

--- Part 3. Electrical equipment data;

--- Part 4. Simultaneous two independent single-phase ground fault current and current through the earth;

--- Part 5. Example.

This section GB/T 15544 Part 3.

This section drafted in accordance with GB/T 1.1-2009 given rules.

This section uses the translation method is equivalent to using IEC TR60909-2:2008 "Three-phase AC system short-circuit current calculation Part 2. Short circuit Current Calculation Applied Electrical Equipment Data ".

This section made the following editorial changes.

--- In line with the existing standard series, the name of this section was changed to "three-phase AC system short-circuit current calculation Part 3. Electrical equipment Prepare data ".

This part is proposed by China Electricity Council.

This part of the national standardization of short-circuit current calculation Technical Committee (SAC/TC424) centralized.

1 Overview

1.1 Scope and objectives

This part of GB/T 15544 covers electrical equipment collected from different countries data, if necessary, can be used in accordance with GB/T 15544.1 into Short circuit current calculation.

The data for electrical equipment is usually provided by the manufacturer as a nameplate parameter or by the power supplier.

In some cases, these data may not be available. When the data given in this section consistent with the typical equipment of the user's country Then these data can be used to calculate the short-circuit current of the LV grid. This section collects data and its evaluation can be applied to medium pressure or high pressure the grid plan can also be used as a comparison with the equipment data provided by the equipment manufacturer or power supplier. For overhead lines and cables, somewhere in these cases, the electrical parameters can be calculated from the dimensions provided in this document based on their dimensions.

This section as a supplement to GB/T 15544.1, does not change the GB/T 15544.1 and GB/T 15544.4 gives standardized calculation Process.

1.2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 15544.1-2013 Three-phase AC system short-circuit current calculation Part 1. Current calculation (IEC 60909-0:2001, IDT) GB/T 15544.4-2017 Three-phase AC system short-circuit current calculation Part 4. Simultaneous two independent single-phase ground fault Current and current through the earth (IEC 60909-3:2009, IDT)

2 Electrical Equipment Data

2.1 Overview

This section provides the data in the calculation of short-circuit current is necessary. The data is given in the form of a curve or tabulation. Overhead lines and electricity the positive sequence of the cable and the zero-sequence short-circuit impedance can be calculated by the formula.

A total of 15 National Committees (NCs) responded to the previous questionnaire in this section.

See Appendix A.

In some cases, the average or characteristic trend of electrical equipment data is based on the rating of the electrical equipment (eg, rated power, rated voltage, etc.) Function form is given.

2.2 Synchronous motor typical data

The characteristic parameters of the synchronous motor are listed in Table 1. Reactance is expressed in terms of per-unit basis with a reference value of ZrG = U2rG/SrG (see GB/T 15544.1) or Given as a percentage value.

Also given in Table 1 zero sequence reactance values, it is recommended to take X (0)/X "d = 0.5.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 31 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 15544.3-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
31 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 15544.3-2017

$475.00