Valid

GB/T 12972.6-2008Flexible rubber-sheathed cables for mining purposes - Part 6: Flexible cables with monitoring core and metallic screens for rated voltages up to 6/10kV (English PDF)

矿用橡套软电缆 第6部分:额定电压6/10kV及以下金属屏蔽监视型软电缆

Preview PDF

This is a limited preview

Buy now to download the full PDF (8 pages)

Need quotation for your management?

Get a formal quotation for GB/T 12972.6-2008 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China

Level / Type

National · Recommended

Issue date

June 30, 2008

Implementation date

April 1, 2009

Scope

GB/T 12972.6-2008 is the English-translated version of 矿用橡套软电缆 第6部分:额定电压6/10kV及以下金属屏蔽监视型软电缆.

GB/T 12972.6-2008 is Part 6 of the Chinese series on flexible rubber-sheathed cables for mining, and specifies the types, technical requirements, test methods and inspection rules of copper-conductor, rubber-insulated, rubber-sheathed flexible cables with metallic screens and monitoring cores for rated voltages U0/U of 3.6/6 kV and 6/10 kV, used to feed underground mobile transformers and similar equipment; it is used together with GB/T 12972.1-2008.

It covers the types UYPTJ-3.6/6 and UYPTJ-6/10 in sizes 3×25 to 3×120 mm2, with the earth conductor formed by the metallic insulation screens, three 2.5 mm2 monitoring cores between semi-conductive tapes, EPR-based IR2 insulation of 4.0 or 4.5 mm, a polychloroprene outer sheath of 5.5 mm, a conductor operating temperature of 90 °C and a minimum bending radius of 6 times the cable diameter.

Requirements and tests include dimensions, conductor resistance, minimum insulation resistance at 20 °C, power-frequency voltage, partial discharge, dielectric loss tangent, impulse and 4 h voltage tests, bunched-cable flame test to GB/T 18380.3, insulation water absorption and the sheath rubber properties of normative Annex A (tensile, elongation, tear, oven and air bomb ageing, oil immersion and hot set).

It replaces GB 12972.6-1991, adding the 6/10 kV cable, extending the 3.6/6 kV range from 50 to 120 mm2, making the partial discharge test a routine test and replacing the single-cable vertical flame test with the bunched-cable test.

It was issued on 30 June 2008 and has been in force since 1 April 2009. Classification: ICS 29.060.20, CCS K13. The document runs to 8 pages, delivered complete in English translation.

Found what you need?

Document preview — GB/T 12972.6-2008

National Standard of the People's Republic of China

ICS
29.060.20
Classification
K13
Replacing
GB 12972.6-1991

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Operating characteristics
  • 4 Model
  • 5 Specifications
  • 6 Technical requirements
  • 7 Finished cable
  • 8 Inspection rules

3 Operating characteristics

4 Model

5 Specifications

6 Technical requirements

7 Finished cable

8 Inspection rules

Foreword

GB/T 12972, Flexible rubber-sheathed cables for mining purposes, is divided into 10 parts:

- Part 1: General;

- Part 2: Flexible cables for coal cutters for rated voltages up to and including 1.9/3.3 kV;

- Part 3: Reinforced screened monitoring flexible cables for coal cutters for rated voltage 0.66/1.14 kV;

- Part 4: Flexible cables with metallic screens for coal cutters for rated voltages up to and including 1.9/3.3 kV;

- Part 5: Mobile rubber-sheathed flexible cables for rated voltages up to and including 0.66/1.14 kV;

- Part 6: Flexible cables with monitoring core and metallic screens for rated voltages up to and including 6/10 kV;

- Part 7: Screened rubber-sheathed flexible cables for rated voltages up to and including 6/10 kV;

- Part 8: Mining electric drill cables for rated voltage 0.3/0.5 kV;

- Part 9: Light mobile rubber-sheathed flexible cables for mining for rated voltage 0.3/0.5 kV;

- Part 10: Miners' cap lamp cords.

This part is Part 6 of GB/T 12972.

This part replaces GB 12972.6-1991, Flexible rubber-sheathed cables for mining purposes - Part 6: Screened monitoring flexible cables for rated voltage 3.6/6 kV.

Compared with GB 12972.6-1991, the main changes in this part are as follows:

- the title has been changed to "Flexible cables with monitoring core and metallic screens for rated voltages up to and including 6/10 kV";

- flexible cables with monitoring core and metallic screens for rated voltage 6/10 kV, and the related requirements, have been added (Tables 1 and 3 of this edition);

- the range of conductor cross-sections for cables of rated voltage U0/U 3.6/6 kV has been extended from 25 mm2 to 50 mm2 to 25 mm2 to 120 mm2 (Table 2 of the 1991 edition; Table 2 of this edition);

- the content on XJ-30A insulating rubber and XJ-10A rubber has been deleted (5.3.1 and 5.5.1 of the 1991 edition);

- the partial discharge test of the cable has been changed from a sample test to a routine test (Table 4 of the 1991 edition; Table 5 of this edition);

- the cable flame test to GB/T 12666.2, Test method for vertical flame propagation of a single wire or cable, has been replaced by the test to GB/T 18380.3, Tests on electric cables under fire conditions - Part 3: Test methods for bunched wires or cables (Table 4 of the 1991 edition; 7.2 of this edition).

Annex A of this part is normative.

This part was proposed by the China Electrical Equipment Industry Association.

This part is under the jurisdiction of the National Technical Committee on Electric Wires and Cables of Standardization Administration of China (SAC/TC 213).

Organisation responsible for drafting this part: Shanghai Electric Cable Research Institute.

Organisations participating in the drafting: Shanghai Branch of China Coal Research Institute, Shanghai Shenghua Cable Group Co., Ltd., Shanghai Nanyang Cable Co., Ltd., Shandong Yankuang Group Changlong Cable Manufacturing Co., Ltd., and Jiangsu Shangshang Cable Group Co., Ltd.

Chief drafters of this part: Zeng Jigang, Tang Jiazi, Xi Hong, Kuang Tianshen, Tan Jinfeng, Li Xingqiang, Yuan Jie.

The previous editions of the standard replaced by this part are:

- GB 1170-1974;

- GB 12972.6-1991.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 8 pages — is available in the English PDF.

Referenced standards

Normative references

GB/T 18380.3-2001

Similar standards

Editions of GB/T 12972.6

EditionTitleRevisionStatus
GB/T 12972.6-2008Flexible rubber-sheathed cables for mining purposes - Part 6: Flexible cables with monitoring core and metallic screens for rated voltages up to 6/10kVcurrent editionCurrent
GB 12972.6-1991Flexible rubber-sheathed cables for mining purposes-Part 6: Flexible cables with monitoring core and semiconducting screens for rated voltage of 3.6/6kVmerged into this editionSuperseded

This page sells the current edition, GB/T 12972.6-2008. Earlier editions are listed for reference only.

How to Download GB/T 12972.6-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
8 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 12972.6-2008

$145.00