GB 5135.9-2018Automatic sprinkler systems - Part 9: Early suppression fast response (ESFR) sprinklers (English PDF)
自动喷水灭火系统 第9部分:早期抑制快速响应(ESFR)喷头
Open the GB 5135.9-2018 preview as PDF
This is a limited preview
Buy now to download the full PDF (58 pages)
Issued by
General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the PRC
Level / Type
National · Mandatory
Issue date
September 17, 2018
Implementation date
April 1, 2019
Scope
GB 5135.9-2018 is the English-translated version of 自动喷水灭火系统 第9部分:早期抑制快速响应(ESFR)喷头.
Part 9 of China's mandatory series on automatic sprinkler systems, covering the ESFR sprinkler - the head designed not to control a warehouse fire but to put it out, and the component that made it possible to protect high-piled storage from the ceiling alone, without the in-rack sprinklers that used to be unavoidable. This part specifies the classification, the nominal operating temperature, the colour marking, the model designation and specifications, the requirements, the test methods, the inspection rules, and the packaging, transport and storage of early suppression fast response sprinklers. The principle is in the name and both halves of it are necessary. Fast response: the thermal element has a low response time index, so the head opens while the fire is still small enough to be beaten. Early suppression: the head delivers a very high flow of large, fast droplets that carry down through the fire plume and wet the burning surface, rather than the fine spray of a standard head, which the plume simply lifts away. Together they change the outcome from control to suppression. The price is that an ESFR system is unforgiving in a way a standard system is not: it depends on a high water supply pressure being genuinely available, on the ceiling clearances and the storage arrangement being what the design assumed, and on obstructions being absent - and if any of those is wrong the head does not underperform gracefully, it fails to suppress. That is why the requirements on the delivered density, the droplet momentum, the distribution and the operating characteristics are as tightly drawn as they are, and why the marking and specification of the head matter as much as its performance. Issued on 17 September 2018 and in force since 1 April 2019, it replaces GB 5135.9-2006.
Document preview — GB 5135.9-2018
National Standard of the People's Republic of China
- ICS
- 13.220.10
- Classification
- C 83
- Replacing
- GB 5135.9-2006
Issued by: General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the PRC
Contents
- 1 Scope1
- 2 Normative references1
- 3 Terms and Definitions1
- 4 Category2
- 5 Nominal operating temperature, color mark and model specification2
- 6 Requirements3
- 7 Test method13
- 8 Inspection rules47
- 53 Appendix D (Normative Appendix) Routine Inspection54
Foreword
Chapters 6 and 8 of this section are mandatory and the rest are recommended. GB 5135 "Fire Sprinkler System" has been released and plans to release the following sections.
--- Part 1. Sprinklers;
--- Part 2. Wet alarm valve, delay device, hydraulic alarm bell;
---Part 3. Water spray nozzles;
---Part 4. Dry alarm valve;
---Part 5. Rain alarm valve;
--- Part 6. General purpose valves;
--- Part 7. Water flow indicator;
--- Part 8. Accelerator;
---Part 9. Early suppression fast response (ESFR) nozzles;
---Part 10. Pressure switch;
--- Part 11. Grooved pipe joints;
---Part 13. Water curtain nozzles;
---Part 14. Preaction devices;
1 Scope
Part 9 of China's mandatory series on automatic sprinkler systems, covering the ESFR sprinkler - the head designed not to control a warehouse fire but to put it out, and the component that made it possible to protect high-piled storage from the ceiling alone, without the in-rack sprinklers that used to be unavoidable. This part specifies the classification, the nominal operating temperature, the colour marking, the model designation and specifications, the requirements, the test methods, the inspection rules, and the packaging, transport and storage of early suppression fast response sprinklers. The principle is in the name and both halves of it are necessary. Fast response: the thermal element has a low response time index, so the head opens while the fire is still small enough to be beaten. Early suppression: the head delivers a very high flow of large, fast droplets that carry down through the fire plume and wet the burning surface, rather than the fine spray of a standard head, which the plume simply lifts away. Together they change the outcome from control to suppression. The price is that an ESFR system is unforgiving in a way a standard system is not: it depends on a high water supply pressure being genuinely available, on the ceiling clearances and the storage arrangement being what the design assumed, and on obstructions being absent - and if any of those is wrong the head does not underperform gracefully, it fails to suppress. That is why the requirements on the delivered density, the droplet momentum, the distribution and the operating characteristics are as tightly drawn as they are, and why the marking and specification of the head matter as much as its performance. Issued on 17 September 2018 and in force since 1 April 2019, it replaces GB 5135.9-2006.
This part of GB 5135 specifies the classification, nominal operating temperature, color marking, and model specifications for early suppression fast response (ESFR) nozzles. Grid, requirements, test methods, inspection rules and packaging, transportation, storage, etc. This section applies to the nominal flow coefficient K202 (sagging type and upright type), K242 (sagging type and upright type), K323 (sagging type), K363 (sag type) early suppression fast response (ESFR) nozzles, other types of early suppression fast response (ESFR) nozzles can be referenced This section. This section does not apply to special application nozzles.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB 5135.1 Automatic sprinkler systems - Part 1. Sprinklers
GB/T 7306.2 55° sealed pipe threads Part 2. Conical internal and conical external threads
GB/T 9969.1 General instructions for the use of industrial products
GB/T 31431-2015 Fire extinguishing system Class A fire test standard burner
3 Terms and definitions
The following terms and definitions as defined in GB 5135.1 apply to this document.
3.1 Conductivity factor A measure of the thermal conductivity of a heat sensitive element of a showerhead and its fixture.
Note. The unit is (meters per second) 2[(m/s) 2].
3.2 Actual watering density actualdelivereddensity ADD The density of sprinkling water that penetrates the fire plume to the surface of the combustion.
3.3 Early suppression of earlysuppression In the early stage of the fire, the sprinkler system can have enough water to quickly act on the fire even if only a few nozzles are activated, and extinguish or suppress the fire. Fire to an acceptable level.
3.4 Early suppression fast response (ESFR) sprinkler earlysuppressionfastresponse (ESFR) automaticsprinkler Under the action of heat, the heat sensitive component is self-started within a predetermined temperature range, and the water is distributed in a certain shape and density in the design.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 58 pages — is available in the English PDF.
Referenced standards
Similar standards
Editions of GB 5135.9
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB 5135.9-2018 | Automatic sprinkler systems - Part 9: Early suppression fast response (ESFR) sprinklers | first revision | Current |
| GB 5135.9-2006 | Automatic sprinkler systems - Part 9: Early suppression fast response (ESFR) sprinklers | first issue | Superseded |
This page sells the current edition, GB 5135.9-2018. Earlier editions are listed for reference only.
How to Buy GB 5135.9-2018
- 1Add to cart. Click the "Buy GB 5135.9-2018" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 5135.1-2019 — Automatic sprinkler systems - Part 1: Sprinklers
GB 5135.10-2006 — Automatic sprinkler system-Part10:Pressure switch
GB 5135.11-2006 — Automatic sprinkler system-Part 11:grooved couplings and fittings
Secure payment via Stripe
Payments accepted
GB 5135.9-2018
$350.00