Scope

GB 5135.9-2018 is the English-translated version of 自动喷水灭火系统 第9部分:早期抑制快速响应(ESFR)喷头.

GB 5135.9-2018 is the Chinese standard "Automatic sprinkler systems - Part 9: Early suppression fast response (ESFR) sprinklers". Its scope clause reads: This part of GB 5135 specifies the classification, nominal operating temperature, color marking, and model specifications for early suppression fast response (ESFR) nozzles.

Grid, requirements, test methods, inspection rules and packaging, transportation, storage, etc. This section applies to the nominal flow coefficient K202 (sagging type and upright type), K242 (sagging type and upright type), K323 (sagging type), K363 (sag type) early suppression fast response (ESFR) nozzles, other types of early suppression fast response (ESFR) nozzles can be referenced This section.

This section does not apply to special application nozzles. Its clauses include terms and definitions.

Found what you need?

Document preview — GB 5135.9-2018

National Standard of the People's Republic of China

ICS
13.220.10
Classification
C 83
Replacing
GB 5135.9-2006

Issued by: General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Category
  • 5 Nominal operating temperature, color mark and model specification
  • 6 Requirements
  • 7 Test method
  • 8 Inspection rules
  • 9 Packaging, transportation and storage
  • Appendix A (informative) Calculation method of error limits
  • Appendix B (Normative) Tolerance
  • Appendix C (informative) Analysis of the strength test of fusible elements
  • Appendix D (Normative Appendix) Routine Inspection

1 Scope

This part of GB 5135 specifies the classification, nominal operating temperature, color marking, and model specifications for early suppression fast response (ESFR) nozzles.

Grid, requirements, test methods, inspection rules and packaging, transportation, storage, etc.

This section applies to the nominal flow coefficient K202 (sagging type and upright type), K242 (sagging type and upright type), K323 (sagging type),

K363 (sag type) early suppression fast response (ESFR) nozzles, other types of early suppression fast response (ESFR) nozzles can be referenced

This section.

This section does not apply to special application nozzles.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.

Pieces. For undated references, the latest edition (including all amendments) applies to this document.

GB 5135.1 Automatic sprinkler systems - Part 1. Sprinklers

GB/T 7306.2 55° sealed pipe threads Part 2. Conical internal and conical external threads

GB/T 9969.1 General instructions for the use of industrial products

GB/T 31431-2015 Fire extinguishing system Class A fire test standard burner

3 Terms and definitions

The following terms and definitions as defined in GB 5135.1 apply to this document.

3.1 Conductivity factor

A measure of the thermal conductivity of a heat sensitive element of a showerhead and its fixture.

Note. The unit is (meters per second)

2[(m/s)

2].

3.2 Actual watering density

ADD The density of sprinkling water that penetrates the fire plume to the surface of the combustion.

3.3 Early suppression of earlysuppression

In the early stage of the fire, the sprinkler system can have enough water to quickly act on the fire even if only a few nozzles are activated, and extinguish or suppress the fire.

Fire to an acceptable level.

3.4 Early suppression fast response (ESFR) sprinkler earlysuppressionfastresponse (ESFR)

Under the action of heat, the heat sensitive component is self-started within a predetermined temperature range, and the water is distributed in a certain shape and density in the design.

GB 13365 | GB 5135.3 | GB 4066 | GB/T 5135.18 | GB 5135.4 | GB 5135.2 | […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 58 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB 5135.9

EditionTitleRevisionStatus
GB 5135.9-2018Automatic sprinkler systems - Part 9: Early suppression fast response (ESFR) sprinklersfirst revisionCurrent
GB 5135.9-2006Automatic sprinkler systems - Part 9: Early suppression fast response (ESFR) sprinklersfirst issueSuperseded

This page sells the current edition, GB 5135.9-2018. Earlier editions are listed for reference only.

How to Download GB 5135.9-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
58 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 5135.9-2018

$340.00