Valid

GB 30439.5-2013Safety requirements for industrial automation products - Part 5: Safety requirements for flowmeter (English PDF)

工业自动化产品安全要求 第5部分: 流量计的安全要求

Open the GB 30439.5-2013 preview as PDF

Preview — first pages of GB 30439.5-2013 (full document: 57 pages)

This is a limited preview

Buy now to download the full PDF (57 pages)

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China

Level / Type

National · Mandatory

Issue date

December 31, 2013

Implementation date

January 1, 2015

Scope

GB 30439.5-2013 is the English-translated version of 工业自动化产品安全要求 第5部分: 流量计的安全要求.

GB 30439.5-2013 is the Chinese national standard on safety requirements for industrial automation products - part 5: safety requirements for flowmeter, in the field of manufacturing engineering. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 31 December 2013 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 January 2015. Classification: ICS 25.040.01, CCS N10. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

Document preview — GB 30439.5-2013

National Standard of the People's Republic of China

ICS
25.040.01
Classification
N10

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 3.1 Equipment and devices
  • 3.2 Parts and Accessories
  • 3.3 Electrical values
  • 3.4 Test
  • 3.6 Insulation
  • 3.6.6.1 Pollution Level 1 polutiondegree
  • 3.6.6.2 Pollution Level 2 polutiondegree
  • 3.6.6.3 Pollution Level 3 polutiondegree
  • 4 Test
  • 4.4 Test under single fault conditions
  • 4.4.2 Fault conditions imposed Fault conditions 4.4.2.1 ~
  • 4.4.2.1 Impedance protection
  • 11 Anti-dangerous fluid 37 12 radiation (including laser source), acoustic and ultrasonic pressure 38 13 pairs of explosion and implosion protection 38
  • 17 Figure 2 charging normal conditions and single fault condition capacity limit [see 6.3.1c) and 6.3.2c)]
  • 33 Temperature limit and thermal equipment 10
  • 46 Table C.1 Pollution Level Table E.1 through the use of additional protection allows to reduce environmental pollution level inside

Foreword

All technical content of this part of GB 30439-2013 is mandatory. GB 30439 "Industrial Automation product safety requirements" is divided into 18 sections as follows:

--- Part 1. General;

--- Part 2. pressure/differential pressure transmitter safety requirements;

--- Part 3. Temperature Transmitter safety requirements;

--- Part 4. Safety requirements for the control valve;

--- Part 5. flowmeter safety requirements;

--- Part 6. solenoid valve safety requirements;

--- Part 7. loop controller safety requirements;

--- Part 8. Safety requirements for electric actuators;

--- Part 9. Digital display instrument safety requirements;

--- Part 10. recording instrument safety requirements;

--- Part 11. Programmable Controller safety requirements;

--- Part 12. Echo Ranging (TOF) Level Meter safety requirements;

--- Part 13. magnetostrictive level gauge safety requirements;

1 Scope

GB 30439.5-2013 is the Chinese national standard on safety requirements for industrial automation products - part 5: safety requirements for flowmeter, in the field of manufacturing engineering. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 31 December 2013 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 January 2015. Classification: ICS 25.040.01, CCS N10. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

GB 30439 of the provisions of this part of the electric shock and industrial processes using flowmeter burns, mechanical hazards, excessive heat, flames from the stream Spread out within a meter, safety requirements affect fluid and fluid pressure, explosion and implosion. This section does not include security-related equipment and reliable function, performance or other characteristics, the effectiveness of transport packaging, electromagnetic compatibility (EMC) requirements for an explosive environment protection measures, maintenance (repair), protective maintenance (repair) personnel. This section applies to flowmeters have electrical outputs. This section does not apply to countries to withstand radioactive specific working conditions Flowmeter. This section does not apply to differential pressure flowmeter and ultrasonic flowmeter.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. Determination of

GB/T 1633-2000 thermoplastics Vicat softening temperature (VST) of

GB/T 4207-2003 solid insulating materials under moist conditions index tracking of the measuring method and the proof tracking index compared

GB 4208-2008 shell protection (IP code)

GB 4793.1-2007 measurement, control and laboratory safety requirements for electrical equipment - Part 1. General requirements

GB 5013 (all parts) rated voltage 450V/750V and below rubber insulated cables

GB 5023 (all parts) rated voltage 450V/750V and below PVC insulated cables

GB/T 5169.16-2008 Fire hazard testing for electric and electronic products - Part 16. Test flames - 50W horizontal and vertical flame experiment method

GB/T 11021-2007 heat resistance, electrical insulation rating

GB/T 12113-2003 touch current and protective conductor current measurement methods

GB/T 16842-2008 housing for people and equipment protection test with a test

GB/T 16927 (all parts) high-voltage test techniques

IEC 60027 electrical technology text symbols (Lettersymbolstobeusedinelectricaltechnology)

IEC 60270 partial discharge measurements (Partialdischargemeasurements)

3 Terms and Definitions

GB 4793.1-2007 defined in the following terms and definitions apply to this document. For ease of use, the following listed repeatedly GB 4793.1-2007 certain terms and definitions. Category

3.1 Equipment and devices

3.1.1 Stationary equipment fixedflowmeter Fixed to the support member or an additional fixture at a specific location. [GB 4793.1-2007, the definition 3.1.1]

3.1.2 PERMANENTLY CONNECTED EQUIPMENT permanentlyconnectedflowmeter Only method of permanent connection with the tool to disconnect the power supply and electrical connection devices. [GB 4793.1-2007, the definition 3.2.2]

3.1.3 Tools tool , Including keys and coins, including an external device to help people to perform some kind of mechanical function and use. [GB 4793.1-2007, the definition 3.1.5]

3.2 Parts and Accessories

3.2.1 Terminal terminal For the apparatus (device) connected to an outer conductor provided in one kind of element. It may contain one or more terminal contacts, so that the term also includes sockets, connectors and the like. [GB 4793.1-2007, the definition 3.2.1]

3.2.2 Functional ground terminal functionalearthterminal To a point directly measuring or control circuit, or directly with a shield portion is electrically connected, but also reservations To be used for any function other than safety purposes purpose a ground terminal. [GB 4793.1-2007, the definition 3.2.2]

3.2.3 Protective Conductor Terminal protectiveconductortriennial For security purposes with the conductive parts of equipment are connected, but also with a predetermined external terminal connected to protective earthing system. [GB 4793.1-2007, the definition 3.2.3]

3.2.4 Housing enclosure Protect the unit against certain external influences and prevent parts from any direct contact with the direction provided. [GB 4793.1-2007, the definition 3.2.4]

3.2.5 Baffle barrier Prevent parts from any direction normal close direct contact provided.

Note. The housing and bezel provides flame spread protection [see 9.2.1b)]. [GB 4793.1-2007, the definition 3.2.5]

3.3 Electrical values

3.3.1 Rated (value) rated (value) Usually by the manufacturer for the components, apparatus, or device reaches a given magnitude of working status. [GB 4793.1-2007, the definition 3.3.1] Rating rating A set of ratings and working conditions. [GB 4793.1-2007, the definition 3.3.2]

3.3.2 Operating voltage workingvoltage When the device is supplied at rated voltage, maximum voltage AC or DC voltage values on any particular insulation can occur.

Note 1. The instantaneous value is not considered.

Note 2. The open circuit conditions and normal operating conditions are to be considered. [GB 4793.1-2007, the definition 3.3.3]

3.4 Test

3.4.1 Type test typetest For a particular design, in order to prove that the design and structure is able to meet one or more requirements of this part and of one or more devices Taiwan sample (or device components) tests carried out. [GB 4793.1-2007, the definition 3.4.1]

3.4.2 Routine tests routinetest After fabrication or manufacture to determine the means (equipment) meets a criterion and for each separate device (device) test (See Appendix F). [GB 4793.1-2007, the definition 3.4.2]

3.5 Security Terminology 3.5.1 (Parts) palpable accessible (ofapart) With the standard test finger or test pin accessible. [GB 4793.1-2007, the definition 3.5.1]

3.5.2 Dangerous hazard Potential source of harm. [GB 4793.1-2007, the definition 3.5.2]

3.5.3 Hazardous live hazardouslive Electric shock or electrical burn make it under normal condition or single fault condition.

Note. The value of the normal conditions apply, see 6.3.1, for higher under a single fault condition is applicable values see section 6.3.2. [GB 4793.1-2007, the definition 3.5.3]

3.5.4 Protective impedance protectiveimpedance A combination of components, component or components of the basic insulation and current limiting or pressure-limiting device when it is connected to ACCESSIBLE conductive parts and dangerous Between live parts when the risk degree of protection impedance, structure and reliability under normal and single fault conditions provided in this section reached Claim. [GB 4793.1-2007, the definition 3.5.7]

3.5.5 Protection connection protectivebonding To make electrical ACCESSIBLE conductive parts or protect the screen and for the external protection conductor is connected with electrical continuity and having carried connection. [GB 4793.1-2007, the definition 3.5.8]

3.5.6 Normal use normaluse Operation according to instructions or intended use by the apparent instructions, including standby. NOTE. In most cases, the normal use also refers to normal conditions, because the use of manual warns users not to use the device under abnormal conditions. [GB 4793.1-2007, the definition 3.5.9]

3.5.7 Normal conditions normalcondition All protective measures to prevent dangerous conditions are intact. [GB 4793.1-2007, the definition 3.5.10]

3.5.8 Single fault condition singlefaultcondition Protective measures to prevent the risk of a failure condition occurs or is likely to cause some dangerous and a fault condition.

Note. If a single fault condition will inevitably lead to another single fault conditions, such a two failures are considered a single fault condition. [GB 4793.1-2007, the definition 3.5.11]

3.5.9 Operator operator According to the intended use of the device to operate the equipment man.

Note. the operator for this purpose should be properly trained. [GB 4793.1-2007, the definition 3.5.12]

3.6 Insulation

3.6.1 Basic insulation basicinsulation Whose failure can cause a shock hazard insulation.

Note. The basic function of insulation can be used for insulation purposes. [GB 4793.1-2007, the definition 3.6.1]

3.6.2 Additional insulation supplementaryinsulation Independent insulation applied in addition to basic insulation, in order to ensure that when once the basic insulation failure can still prevent electric shock. [GB 4793.1-2007, the definition 3.6.2]

3.6.3 Double insulation doubleinsulation Constituted by the basic insulation and supplementary insulation. [GB 4793.1-2007, the definition 3.6.3]

3.6.4 Reinforced insulation reinforcedinsulation Its ability to provide protection against electric shock is not less than double insulation insulation, it can not as a separate image into several layers of additional insulation or basic insulation Insulation test line configuration. [GB 4793.1-2007, the definition 3.6.4]

3.6.5 Pollution polution It will lead dielectric strength or surface resistivity reduced solid, liquid or gaseous (ionized gas) additional foreign substances. [GB 4793.1-2007, the definition 3.6.5]

3.6.6 Pollution degree (in the micro-environment) polutiondegree (inthemicro-environment) To determine the clearances and creepage distances, the pollution degree microenvironment as the following three grades.

Note 1. The build-up of foreign matter and moisture can cause conductive insulator contamination.

Note 2. The minimum clearances for pollution degree Pollution Degree 2 and 3 are given based on experience rather than raw data. [GB 4793.1-2007, the definition 3.6.6]

3.6.6.1 Pollution Level 1 polutiondegree

1 Pollution can only dry non-conductive pollution, the pollution has no adverse effect. [GB 4793.1-2007, the definition 3.6.6.1]

3.6.6.2 Pollution Level 2 polutiondegree

2 Normally only non-conductive pollution, but occasionally due to condensation and short conductive. [GB 4793.1-2007, the definition 3.6.6.2]

3.6.6.3 Pollution Level 3 polutiondegree

3 Conductive pollution or dry non-conductive pollution which becomes conductive due to condensation.

Note. In this condition, the device is usually to prevent exposure to direct sunlight, rain, strong wind pressure, but it need not control the temperature or humidity. [GB 4793.1-2007, the definition 3.6.6.3]

3.6.7 Clearance clearance Space the shortest distance between two conductive parts. [GB 4793.1-2007, the definition 3.6.7]

3.6.8 Creepage distance creepagedistance Along the shortest distance between two conductive insulating solid surface material parts. [IEV151-15-50] [GB 4793.1-2007, the definition 3.6.8]

3.7 and associated product definition

3.7.1 Flowmeter flowmeter Flow measuring instruments. Usually it consists of primary and secondary device component unit.

3.7.2 A means primarydevice Means for generating traffic signal. According to the principle employed, a device may be inside or outside the pipe.

3.7.3 Secondary means secondarydevice Receiving a signal from a device and display, record, convert and (or) means transmitting the signal to obtain flow values.

3.7.4 Power supply mains The use of the meter is designed to require that they are connected to the meter to provide electricity for the purpose of low voltage power supply system.

3.7.5 Power supply circuit mainscircuit Intended to be connected with the power supply for providing power meter circuit.

4 Test

4.1 Overview In this section all tests are type tests on the sample meter or components carried out. The only purpose of these tests is to Verify that the design and construction to ensure compliance with this requirement. In addition, the manufacturer shall produced at the same time dangerous live parts And accessible conductive parts of the flow meter 100% of routine tests in Appendix F of. Satisfy the provisions of this part of the relevant standards and requirements for use according to these sub-assemblies flowmeter flowmeter types throughout the test You do not have to repeat the test during the test. It should be checked by all applicable test meets the requirements of this section, but if the examination of the meter can really prove certainly pass Had a trial, then this test may be omitted. Test under the following conditions.

--- Reference test conditions (see 4.3);

--- Fault conditions (see 4.4). NOTE. If performing compliance test, or a measured value of the applied (such as voltage) of the actual value due to errors and uncertainty, then.

--- Manufacturer to ensure that the value of the test is applied to at least a predetermined value;

--- Test departments should ensure that the test applied is not greater than the value specified.

4.2 Test procedure Except as otherwise provided by this section, the test sequence may be optionally substituted. After each trial to test the meter should be carefully checked. Such as If test results are suspect, suspect that if the test sequence reversed, any of the foregoing whether true test pass, then test in front of them Test should be repeated. If the test can damage the meter under fault conditions, these tests can be placed under the test conditions of the reference test after that.

4.3 reference test conditions

4.3.1 Environmental Conditions Except as otherwise provided by this section, test sites should have the following conditions.

a) Temperature. 15 °C ~ 35 °C;

b) Relative humidity. not exceed 75%;

c) Atmospheric pressure. 86kPa ~ 106kPa;

d) no frost, condensation, water seepage, rain and sunshine.

4.3.2 Flowmeter status Unless otherwise provided, each test should be assembled at the meter for normal use, and the provisions in 4.3.2.1 ~

4.3.2.9 Carried out under the most unfavorable combination of conditions. If the volume or mass flow meters reasons can not be certain the entire test, the test allows for sub-assemblies, as long as after inspection Certify that the assembled flowmeters to meet the requirements of this section. It should be specified by the manufacturer's instructions for installation.

4.4 Test under single fault conditions

4.4.1 Overview It should be according to the following requirements. Fault

a) Check the meter and the circuit diagram can usually determine whether there may be dangerous and therefore whether it should be applied condition;

b) In addition to proof of a specific fault conditions likely to cause danger, the test shall be made by the fault, or select Check Verify compliance provisions of an alternative method to replace the failure test;

c) the reference flowmeter shall work under test conditions (see 4.3) the most unfavorable combination of conditions, for different faults, which combined strip Member can vary, these combined conditions should be recorded during each test.

4.4.2 Fault conditions imposed Fault conditions 4.4.2.1 ~

4.4.2.6 should include provisions for fault conditions. These fault conditions can only be applied to one and should press Sequentially applied in any convenient order, can not be applied more than one fault at the same time, the results unless it is applied to a fault caused by a fault. After each applied once the fault condition, the flow meter or parts shall pass the applicable test 4.4.4.

4.4.2.1 Impedance protection

a) If the impedance protection is a combination of components to form, it should be shorted or open each component, choose one of the more not Lee's.

b) If the impedance protection by basic insulation and current limiting or pressure-limiting devices to form, the basic insulation and current limiting pressure limiting device, or both Caught should afford a single fault condition, once applied to a fault condition. Basic insulation should be short-circuited, while limiting Or pressure-limiting...

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 57 pages — is available in the English PDF.

Referenced standards

Normative references

GB/T 1633-2000 · GB/T 4207-2003 · GB 4208-2008 · GB 4793.1-2007 · GB 5013 · GB 5023 · GB/T 5169.16-2008 · GB/T 11021-2007 · GB/T 12113-2003 · GB/T 16842-2008 · GB/T 16927 · IEC 60027 · IEC 60270

Similar standards

Editions of GB 30439.5

EditionTitleRevisionStatus
GB 30439.5-2013Safety requirements for industrial automation products - Part 5: Safety requirements for flowmetercurrent editionCurrent

This page sells the current edition, GB 30439.5-2013. Earlier editions are listed for reference only.

How to Buy GB 30439.5-2013

  1. 1Add to cart. Click the "Buy GB 30439.5-2013" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
57 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 30439.5-2013

$800.00

$680.00for partners