Scope
GB 30439.1-2013 is the English-translated version of 工业自动化产品安全要求 第1部分: 总则.
GB 30439.1-2013 is the Chinese national standard on safety requirements for industrial automation products - part 1: general requirements, in the field of manufacturing engineering. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 31 December 2013 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 January 2015. Classification: ICS 25.040.01, CCS N10. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.
Document preview — GB 30439.1-2013
National Standard of the People's Republic of China
- ICS
- 25.040.01
- Classification
- N10
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 3.1 Equipment and devices
- 3.2 Parts and Accessories
- 3.3 Electrical values
- 3.3.2 Rating rating A set of ratings and working conditions. [IEV151-04-04]
- 3.4 Test
- 3.6 Insulation
- 3.6.5.1 Pollution Level 1 polutiondegree
- 3.6.5.2 Pollution Level 2 polutiondegree
- 3.6.5.3 Pollution Level 3 polutiondegree
- 4 Test
- 4.3.2.8 Output For providing an electrical output device. Working conditions
- 4.4 Test under single fault conditions
- 4.4.2 Fault conditions imposed Fault conditions 4.4.2.1 ~
Foreword
In addition to all the technical content of GB 30439 Appendix A of this section is mandatory. GB 30439 "Industrial Automation product safety requirements" is currently divided into 18 parts.
--- Part 1. General;
--- Part 2. pressure/differential pressure transmitter safety requirements;
--- Part 3. Temperature Transmitter safety requirements;
--- Part 4. Safety requirements for the control valve;
--- Part 5. flowmeter safety requirements;
--- Part 6. solenoid valve safety requirements;
--- Part 7. loop controller safety requirements;
--- Part 8. Safety requirements for electric actuators;
--- Part 9. Digital display instrument safety requirements;
--- Part 10. recording instrument safety requirements;
--- Part 11. Programmable Controller safety requirements;
--- Part 12. Echo Ranging (TOF) Level Meter safety requirements;
--- Part 13. magnetostrictive level gauge safety requirements;
1 Scope
GB 30439.1-2013 is the Chinese national standard on safety requirements for industrial automation products - part 1: general requirements, in the field of manufacturing engineering. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 31 December 2013 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 January 2015. Classification: ICS 25.040.01, CCS N10. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.
This section GB 30439 provisions of industrial automation products and electrical burns against electric shock, against mechanical hazards and fire prevention equipment from the inside out Spread against excessive heat, fluid-fluid pressure and the influence of radiation impact (including lasers, sound and ultrasonic pressure) and release of gas Body, explosion and implosion of security content. This section does not include security features and device-independent, performance or other characteristics, the effectiveness of transport packaging, electromagnetic compatibility (EMC) to Requirements, functional safety, environmental protection measures for the explosion, maintenance (repair), maintenance (repair) personnel protection. If you want other industrial automation products for the environment (such as buildings, medical, etc.), automation products must also meet applicable to the respective Special environmental requirements, standards and installation guidelines. This section applies to industrial manufacturing or processing, continuous automatic measurement, temperature control, material or product, pressure, flow and other parameters The amount of industrial automation systems, instruments and devices. This section also applies to the predetermined attachment and automation products used together (such as instrument calibration Means).
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 4213-2008 pneumatic control valve
GB 4793.1-2007 measurement, control and laboratory safety requirements for electrical equipment - Part 1. General requirements
GB/T 7635.1-2002 national main product categories and codes - Part 1. Transportation Products
GB/T 11918-2001 industrial plug and socket couplers - Part 1. General requirements
GB/T 11919-2001 industrial plug and socket coupling - Part 2. With pin and sleeve size interchangeable electrical accessories Requirements
GB/T 15969.2-2008 Programmable Controllers Part 2. Equipment Requirements and Tests
GB 30439.2 industrial automation product safety requirements - Part 2. Safety requirements for pressure/differential pressure transmitter
GB 30439.3 Industrial Automation Products Safety requirements - Part 3. Safety requirements Temperature Transmitter
GB 30439.4 industrial automation product safety requirements - Part 4. Safety requirements for control valves
GB 30439.5 industrial automation product safety requirements - Part 5. Safety requirements Flowmeter
GB 30439.6 industrial automation product safety requirements - Part 6. Safety requirements for solenoid valves
GB 30439.7 industrial automation product safety requirements - Part 7. Safety requirements loop controller
GB 30439.8 Safety requirements for industrial automation products Part 8. Safety requirements for electric actuators
3 Terms and Definitions
GB 4793.1-2007 and GB/T 15969.2-2008 and as defined in the following terms and definitions apply to this document. In order to facilitate Use the following list of repeated GB 4793.1-2007 and GB/T 15969.2-2008 in some terms and definitions. Category
3.1 Equipment and devices
3.1.1 Stationary equipment fixedequipment Fixed to the support member or an additional fixture at a specific location. [GB 4793.1-2007, the definition 3.1.1]
3.1.2 PERMANENTLY CONNECTED EQUIPMENT permanentlyconnectedequipment Scheduled to use screw terminals or other reliable methods and building installation wiring connected device. [GB 4793.1-2007, the definition 3.1.2]
3.1.3 Portable device portableequipment A closed system, it can be moved in operation, along with the power supply or can it be easily moved from one location to another. example For example, programming and debugging tool (PADT) and test equipment (TE). [GB 4793.1-2007, the definition 3.1.3]
3.1.4 Tools tool To help people to perform some kind of mechanical function and use, including keys and coins, including an external device. [GB 4793.1-2007, the definition 3.1.5]
3.2 Parts and Accessories
3.2.1 Protective conductor protectiveconductor For security purposes (for example, protection against electric shock) to provide a conductor. [GB/T 15969.2-2008, the definition 3.53]
3.2.2 Housing enclosure Provide protection suitable for the intended application and the type of housing protection rating. [GB/T 15969.2-2008, the definition 3.19]
3.3 Electrical values
3.3.1 Rated (value) rated (value) Usually by the manufacturer for the components, apparatus, or device reaches a given magnitude of working status. [IEV151-04-03]
3.4 Test
3.4.1 Type test typetest For one or more products of the project done by a representative compliance testing. [GB 4793.1-2007, the definition 3.4.1]
3.4.2 Routine tests (routine tests) routinetest During or after the manufacturing of various technical indicators do conformance testing. [GB 4793.1-2007, the definition 3.4.2]
3.5 Security Terminology 3.5.1 (Parts) palpable accessible (ofapart) GB 4793.1-2007 in accordance with the provisions of
6.2 can be the standard test finger or test pin to the touch. [GB 4793.1-2007, the definition 3.5.1]
3.5.2 Dangerous hazard Potential source of harm. [GB 4793.1-2007, the definition 3.5.2]
3.5.3 Hazardous live hazardouslive It means capable of causing electrical shock or burns under normal conditions of use or single fault condition. Under normal conditions of use apply to the value of GB 4793.1-2007 see 6.3.1; for under a single fault condition values see GB 4793.1- 2007 6.3.2. [GB 4793.1-2007, the definition 3.5.3]
3.5.4 Power supply mains It is designed to make about the device connected thereto need for equipment to provide electricity for the purpose of low voltage power supply system. [GB 4793.1-2007, the definition 3.5.5]
3.5.5 MAINS circuit mainscircuit Intended to be connected to the power grid, providing power for the device circuitry. [GB 4793.1-2007, the definition 3.5.6]
3.5.6 Normal conditions normalcondition All protective measures to prevent dangerous conditions are intact. [GB 4793.1-2007, the definition 3.5.10]
3.5.7 Single fault condition singlefaultcondition Protective measures to prevent the risk of a failure condition occurs or is likely to cause some dangerous and a fault condition.
Note. If a single fault condition will inevitably lead to another single fault conditions, such a two failures are considered a single fault condition. [GB 4793.1-2007, the definition 3.5.11]
3.5.8 Operator operator According to the intended use of the device to operate the equipment man.
Note. the operator for this purpose should be properly trained. [GB 4793.1-2007, the definition 3.5.12]
3.5.9 Transient overvoltage transientovervoltage Transient overvoltage is a few milliseconds or less short time overvoltage, oscillation or oscillations, usually high damping.
3.6 Insulation
3.6.1 Basic insulation basicinsulation Insulation HAZARDOUS LIVE parts which provides basic protection. [GB 4793.1-2007, the definition 3.6.1]
3.6.2 Additional insulation supplementaryinsulation In addition to basic insulation independent insulation outside also uses for fault protection. [GB 4793.1-2007, the definition 3.6.2]
3.6.3 Double insulation doubleinsulation Constituted by the basic insulation and supplementary insulation. [GB 4793.1-2007, the definition 3.6.3]
3.6.4 Reinforced insulation reinforcedinsulation Insulation dangerous live parts, which provides insulation equivalent to double the level of protection against electric shock. NOTE. Reinforced insulation may comprise several layers, these layers can not be alone as a basic or supplementary insulation testing. [GB 4793.1-2007, the definition 3.6.4]
3.6.5 Pollution degree (in the micro-environment) polutiondegree (inthemicro-environment) To determine the clearances and creepage distances, the pollution degree microenvironment as the following three grades.
Note 1. The build-up of foreign matter and moisture can cause conductive insulator contamination.
Note 2. The minimum clearances for pollution degree Pollution Degree 2 and 3 are given based on experience rather than raw data. [GB 4793.1-2007, the definition 3.6.6]
3.6.5.1 Pollution Level 1 polutiondegree
1 No pollution or only dry non-conductive pollution, the pollution has no adverse effect. [GB 4793.1-2007, the definition 3.6.6.1]
3.6.5.2 Pollution Level 2 polutiondegree
2 Normally only non-conductive pollution, but occasionally due to condensation and short conductive. [GB 4793.1-2007, the definition 3.6.6.2]
3.6.5.3 Pollution Level 3 polutiondegree
3 Conductive pollution or dry non-conductive pollution which becomes conductive due to condensation.
Note. In this condition, the device is usually to prevent exposure to direct sunlight, rain, strong wind pressure, but it need not control the temperature or humidity. [GB 4793.1-2007, the definition 3.6.6.3]
3.6.6 Clearance clearance Space the shortest distance between two conductive parts. [GB 4793.1-2007, the definition 3.6.7]
3.6.7 Creepage distance creepagedistance Along the shortest distance between two conductive insulating solid surface material parts. [GB 4793.1-2007, the definition 3.6.8]
3.6.8 Microenvironment micro-environment In the study of environmental conditions or climbing clearance distances around. Environmental clearances or creepage distances microenvironment determines the insulating effect, rather than the device determines the insulating effect. Microenvironment than Environmental equipment may be better, it could be worse. It includes all of the factors affecting the insulation, e.g., weather, electromagnetic, pollution. see IEC 60664. [GB/T 15969.2-2008, the definition 3.38]
4 Test
4.1 Overview In this section all tests are type tests on the sample devices or components carried out. The only purpose of these tests is to check Whether the experimental design and construction to ensure compliance. In addition, the manufacturer shall produced at the same time dangerous live parts and ACCESSIBLE conductive parts of the device to 100% of routine tests in Appendix F of GB 4793.1-2007. Satisfy the provisions of this part of the relevant standards and requirements for use by these sub-assembly of the apparatus, the entire apparatus of the type test Inter do not have to repeat the test. It should be checked by all applicable test meets the requirements of this section, but if the inspection of the equipment can really prove will pass A trial, then this test may be omitted. Test under the following conditions.
--- Reference test conditions (see 4.3);
--- Fault conditions (see 4.4). NOTE. If performing compliance test, or a measured value of the applied (such as voltage) of the actual value due to errors and uncertainty, then.
--- Manufacturer to ensure that the value of the test is applied to at least a predetermined value;
--- Test departments should ensure that the test applied is not greater than the value specified.
4.2 Test procedure Subject to the provisions of this section, the test sequence may be optionally substituted. After each test should be carefully checked for the EUT. If you Test results in doubt, doubt if the test reverse the order of the trial whether any of the preceding pass true, the front of these tests should When repeated. If the test could damage the device under a single fault condition, these tests can be placed under the test conditions of the reference test after that.
4.3 reference test conditions
4.3.1 Environmental Conditions Subject to the provisions of this section, the test sites should have the following conditions.
a) Temperature. 15 °C ~ 35 °C;
b) Relative humidity. not exceed 75%;
c) Atmospheric pressure. 86kPa ~ 106kPa;
d) no frost, condensation, water seepage, rain and sunshine.
4.3.2 Device Status Unless otherwise specified, each test should be assembled on the device for normal use, and in the provisions of 4.3.2.1 ~
4.3.2.9 least Benefit under a combination of conditions. It should provide instructions provided by the manufacturer to install.
4.3.2.8 Output For providing an electrical output device. Working conditions
a) equipment should be able to provide the rated output power of the rated load;
b) to any output, rated load impedance should be connected or not.
4.3.2.9 duty cycle Short-term or intermittent operation of the device shall be according to the instructions of the manufacturer, with the longest period of time and work in the shortest possible period Time to recover.
4.4 Test under single fault conditions
4.4.1 Overview It should be according to the following requirements.
a) Check the device and circuit diagram can usually determine whether there is likely to cause dangerous fault conditions and therefore whether it should be applied.
b) In addition to proof of a specific fault conditions likely to cause danger, the test shall be made by the fault, or select test Alternative method of compliance prescribed in place of fault testing [see GB 4793.1-2007 of 9b) and 9c)].
c) device should work under reference test conditions (see 4.3) the most unfavorable combination of conditions, for different faults, these combined conditions You can vary the combination of these conditions should be recorded during each test.
4.4.2 Fault conditions imposed Fault conditions 4.4.2.1 ~
4.4.2.7 should include provisions for fault conditions. These fault conditions can only be applied to one and should press Sequentially applied in any convenient order, can not be applied more than one fault at the same time, the results unless it is applied to a fault caused by a fault. After each applied once the fault condition, equipment or parts shall pass the applicable test 4.4.4.
4.4.2.1 Protective conductor Protective conductor should be disconnected, but permanently connected devices or comply with GB/T 11918 ~ GB/T 11919 of the connector is provided Preparation excluded.
4.4.2.2 short-time or intermittent operation of equipment or components If the single fault conditions can cause these devices or components for work, it should make it work continuously. The individual zero Member includes motors, relays and other electromagnetic devices.
4.4.2.3 Motor Motor should stop it or prevent it from starting when fully energized and choose one of the more disadvantaged.
4.4.2.4 Capacitors Motor auxiliary winding circuit capacitor (except for self-healing capacitors) should be short-circuited.
4.4.2.5 Power Transformers The secondary winding of the power transformer should be required to 4.4.2.5.1 will be short-circuited, according to the provisions of 4.4.2.5.2 it is overloaded. at a Test damaged transformer, allows for repair or replacement before the next test. 4.4.2.5.1 Short circuit Each and every part of the output winding tapped output winding taps without load connected during normal use should turn again Test, a test to simulate a load short circuit. Test overcurrent protection device remains in place, all other windings connected to the load or no load connected, Select the loading conditions of normal use of the more disadvantaged. 4.4.2.5.2 Overload Each part of the output of each winding is not tapped and tapped output winding overload test shall be carried out sequentially, a first test A. Other windings are connected to load or not load, select a load of normal use of the more disadvantaged. If the fault condition test
4.4 Any overload, the individual secondary windings should bear those overloaded. On winding connected across a variable resistor overload test. Resistor adjust as quickly as possible, if necessary, in 1min After re-adjust to maintain the applicable overload. After allow no further adjustment. If the current interrupting device to provide protection, the overload test current of overcurrent protective device can be turned on just 1h maximum current. Before the test, the protection device can be negligible impedance connection instead. If the test current value can not be obtained from the normative protection device, then To be determined by experiment. When the design to achieve the required output voltage overload disappears equipment overload slowly increased, reaching just cause the output power The disappearance of the overload point pressure overload front of a point. In all other cases, the overload is the maximum output power from the transformer can be obtained. Having to meet GB transformer overtemperature protection requirements 4793.1-2007 14.3, during the short-circuit tests 4.4.2.5.1 no longer Withstand overload test. 4.4.2...
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 34 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 4213-2008Pneumatic control valves
- GB 30439.2Safety requirements for industrial automation products - Part 2: Safety requirements for pressure (differential) transmitter
- GB 30439.3Safety requirements for industrial automation products-Part 3: Safety requirements for temperature transmitter
- GB 30439.4Safety requirements for industrial automation products - Part 4: Safety requirements for control valve
- GB 30439.5Safety requirements for industrial automation products - Part 5: Safety requirements for flowmeter
- GB 30439.6Safety requirements for industry products-Part 6: Safety requirements for solenoid valve
GB 4793.1-2007 · GB/T 7635.1-2002 · GB/T 11918-2001 · GB/T 11919-2001 · GB/T 15969.2-2008 · IEC 60027 · IEC 60664
Similar standards
Editions of GB 30439.1
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB 30439.1-2013 | Safety requirements for industrial automation products - Part 1: General requirements | current edition | Current |
This page sells the current edition, GB 30439.1-2013. Earlier editions are listed for reference only.
How to Buy GB 30439.1-2013
- 1Add to cart. Click the "Buy GB 30439.1-2013" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 30439.2-2013 — Safety requirements for industrial automation products - Part 2: Safety requirements for pressure (differential) transmitter
GB 30439.3-2013 — Safety requirements for industrial automation products-Part 3: Safety requirements for temperature transmitter
GB 30439.4-2013 — Safety requirements for industrial automation products - Part 4: Safety requirements for control valve
Secure payment via Stripe
Payments accepted
GB 30439.1-2013
$350.00