Scope

GB 30439.3-2013 is the English-translated version of 工业自动化产品安全要求 第3部分: 温度变送器的安全要求.

GB 30439.3-2013 is the Chinese national standard on safety requirements for industrial automation products-part 3: safety requirements for temperature transmitter, in the field of manufacturing engineering. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 31 December 2013 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 January 2015. Classification: ICS 25.040.01, CCS N10. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

Document preview — GB 30439.3-2013

National Standard of the People's Republic of China

ICS
25.040.01
Classification
N10

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 3.1 Equipment and devices
  • 3.2 Parts and Accessories
  • 3.3 Electrical values
  • 3.4 Test
  • 3.5 Security Terminology 3.5.1 (Parts) palpable accessible (ofapart)
  • 3.6 Insulation
  • 3.6.6.1 Pollution Level 1 polutiondegree
  • 3.6.6.2 Pollution Level 2 polutiondegree
  • 3.6.6.3 Pollution Level 3 polutiondegree
  • 4 Test
  • 4.3.2.8 Output For providing an electrical output of the transmitter. Working condition
  • 4.4 Test under single fault conditions
  • 4.4.2 Fault conditions imposed Fault conditions 4.4.2.1 ~
  • 4.4.2.1 Impedance protection
  • 11 Anti-dangerous fluid 34 12 radiation (including laser source), acoustic and ultrasonic pressure 34 13 pairs of gas release, explosion and implosion protection 34
  • 15 Figure 2 under single fault conditions can instantaneously reach maximum short duration voltage [see 6.3.2a)]
  • 27 Temperature limit and thermal equipment 10
  • 29 Regional structure of FIG. 6 to comply 9.3.1b) 1) the provisions of the housing bottom
  • 41 Table E.1 given additional protection through the use of so reduce pollution levels inside

Foreword

All technical content of this part of GB 30439-2013 is mandatory. GB 30439 "Industrial Automation product safety requirements" is divided into 18 sections as follows:

--- Part 1. General;

--- Part 2. pressure/differential pressure transmitter safety requirements;

--- Part 3. Temperature Transmitter safety requirements;

--- Part 4. Safety requirements for the control valve;

--- Part 5. flowmeter safety requirements;

--- Part 6. solenoid valve safety requirements;

--- Part 7. loop controller safety requirements;

--- Part 8. Safety requirements for electric actuators;

--- Part 9. Digital display instrument safety requirements;

--- Part 10. recording instrument safety requirements;

--- Part 11. Programmable Controller safety requirements;

--- Part 12. Radar level meter and ultrasonic level meter safety requirements;

--- Part 13. magnetostrictive level gauge safety requirements;

1 Scope

GB 30439.3-2013 is the Chinese national standard on safety requirements for industrial automation products-part 3: safety requirements for temperature transmitter, in the field of manufacturing engineering. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 31 December 2013 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 January 2015. Classification: ICS 25.040.01, CCS N10. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

GB 30439 provisions of this part of the industrial processes used in temperature transmitters (hereinafter referred to as transmitter) protection against electric shock and electrical burns, anti-machine Mechanical dangerous, anti-flame spread outward from inside the transmitter, anti-over effect of heat secure content. This section does not include security features and device-independent, performance or other characteristics, the effectiveness of transport packaging, electromagnetic compatibility (EMC) to Requirements, functional safety, environmental protection measures for the explosion, maintenance (repair), maintenance (repair) personnel protection. This section applies to industrial process measurement and control transmitter.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. Determination of

GB/T 1633-2000 thermoplastics Vicat softening temperature (VST) of

GB/T 3098.1-2000 Mechanical properties of fasteners Bolts, screws and studs

GB/T 3098.3-2000 Mechanical properties of fasteners Set screws

GB/T 4207-2003 solid insulating materials under moist conditions index tracking of the measuring method and the proof tracking index compared

GB 4208-2008 shell protection (IP code)

GB 4793.1-2007 measurement, control and laboratory safety requirements for electrical equipment - Part 1. General requirements

GB/T 5465.2-2008 Graphical symbols for electrical equipment - Part 2. Graphical symbols

GB/T 7354-2003 partial discharge measurement

GB 9364.1-1997 Miniature fuses - Part 1. Definitions and miniature fuses and general requirements for miniature fuse-links

GB 9364.2-1997 Miniature fuses - Part 2. Cartridge fuse

GB 9364.3-1997 Miniature fuses - Part 3. ultra-small fuse

GB 9364.4-2006 Miniature fuses - Part 4. Universal modular fuse Listing flammability test method

GB/T 11020-2005 solid non-metallic materials when exposed to flame sources

3 Terms and Definitions

GB 4793.1-2007 defined and the following terms and definitions apply to this document. For ease of use, repeat the following list The GB 4793.1-2007 certain terms and definitions. Unless otherwise specified, "voltage" value and "current" refers to the value of RMS AC, DC, or synthetic voltage or current. Category

3.1 Equipment and devices

3.1.1 Stationary equipment fixedequipment Fixed to the support member or an additional fixture at a specific location. [GB 4793.1-2007, the definition 3.1.1]

3.1.2 PERMANENTLY CONNECTED EQUIPMENT permanentlyconnectedequipment Scheduled to use screw terminals or other reliable methods and building installation wiring connected device.

3.1.3 Portable device portableequipment A closed system, it can be moved in operation, along with the power supply or can it be easily moved from one location to another. example For example, programming and debugging tool (PADT) and test equipment (TE).

3.1.4 Handheld device hand-heldequipment One of the available single-handedly carrying the other hand operated device.

3.1.5 Tools tool To help people to perform some kind of mechanical function and use, including keys and coins, including an external device. [GB 4793.1-2007, the definition 3.1.5]

3.2 Parts and Accessories

3.2.1 Terminal terminal A component of the apparatus (device) connected to the outer conductor provided.

Note. The terminal can contain one or more contacts, so that the term also includes sockets, connectors and the like.

3.2.2 Functional ground terminal functionalearthingterminal To a point directly measuring or control circuit, or directly with a shield portion is electrically connected, but also reservations To be used for any function other than safety purposes purpose a ground terminal.

3.2.3 Protective Conductor Terminal protectiveconductorterminal For security purposes and conductive parts of equipment are connected, but also with a predetermined external terminal connected to protective earthing system.

3.2.4 Protective conductor protectiveconductor For security purposes (for example, protection against electric shock) to provide a conductor.

3.2.5 Housing enclosure Provide protection suitable for the intended application and the type of housing protection rating. [GB 4793.1-2007, the definition 3.2.4]

3.2.6 Baffle barrier Prevent parts from any direction normal close direct contact provided. [GB 4793.1-2007, the definition 3.2.5]

3.3 Electrical values

3.3.1 Rated (value) rated (value) Usually by the manufacturer for the components, apparatus, or device reaches a given magnitude of working status. [GB 4793.1-2007, the definition 3.3.1]

3.3.2 Rating rating A set of ratings and working conditions. [GB 4793.1-2007, the definition 3.3.2]

3.3.3 Operating voltage workingvoltage When the device is working under conditions of normal use, considered on insulation or components are exposed to or be able to withstand a maximum voltage.

Note 1. The instantaneous voltage is not considered.

Note 2. The open circuit conditions and normal conditions are to be considered.

3.4 Test

3.4.1 Type test typetest For one or more products of the project done by a representative compliance testing. [GB 4793.1-2007, the definition 3.4.1]

3.4.2 Routine tests (routine tests) routinetest During or after the manufacturing of various technical indicators do conformance testing. [GB 4793.1-2007, the definition 3.4.2]

3.5 Security Terminology 3.5.1 (Parts) palpable accessible (ofapart)

6.2 When prescribed use standard test finger or test pin accessible. [GB 4793.1-2007, the definition 3.5.1]

3.5.2 Dangerous hazard Potential source of harm.

3.5.3 Hazardous live hazardouslive It means capable of causing electrical shock or burns under normal conditions of use or single fault condition. Applicable under normal conditions of use values refer to GB 4793.1-2007 specified in 6.3.1; values apply to single fault conditions, see GB 4793.1-2007 specified in 6.3.2.

3.5.4 Power supply mains It is designed to make about the device connected thereto need for equipment to provide electricity for the purpose of low voltage power supply system.

3.5.5 MAINS circuit mainscircuit Intended to be connected with the power supply, the device providing power circuits.

3.5.6 Protective impedance protectiveimpedance It is treated as a single component failures, component or a combination of basic insulation and limiting/pressure limiting device combination. Impedance, structure and Reliability is such that, when between hazardous live parts and accessible conductive parts are connected, which provide normal conditions and single fault conditions Under this section the required degree of protection.

3.5.7 Protection connection protectivebonding To make electrical ACCESSIBLE conductive parts or protective screen and for the external protection conductor is connected with electrical continuity and having carried connection.

3.5.8 Normal use normaluse Operation according to instructions or intended use by the apparent instructions, including standby. In most cases, the normal use also refers to normal conditions, because the use of manual warns users not to use the change in non-normal conditions Transmitter.

3.5.9 Normal conditions normalcondition All protective measures to prevent dangerous conditions are perfect, that is no fault condition.

3.5.10 Single fault condition singlefaultcondition Protective measures to prevent the risk of a failure condition occurs or is likely to cause some dangerous and a fault condition.

Note. If a single fault condition will inevitably lead to another single fault conditions, such a two failures are considered a single fault condition.

3.5.11 Operator operator According to the intended use of the device to operate the equipment man.

Note. the operator for this purpose should be properly trained.

3.5.12 Responsible responsiblebody Responsible for the maintenance and use of equipment or operating personnel to ensure adequate training for individuals or organizations.

3.6 Insulation

3.6.1 Basic insulation basicinsulation Insulation HAZARDOUS LIVE parts which provides basic protection. [GB 4793.1-2007, the definition 3.6.1]

3.6.2 Additional insulation supplementaryinsulation In addition to basic insulation independent insulation outside also uses for fault protection. [GB 4793.1-2007, the definition 3.6.2]

3.6.3 Double insulation doubleinsulation Constituted by the basic insulation and supplementary insulation. [GB 4793.1-2007, the definition 3.6.3]

3.6.4 Reinforced insulation reinforcedinsulation Insulation dangerous live parts, which provides insulation equivalent to double the level of protection against electric shock. NOTE. Reinforced insulation may comprise several layers, these layers can not be alone as a basic or supplementary insulation testing. [GB 4793.1-2007, the definition 3.6.4]

3.6.5 Pollution polution It will lead dielectric strength or surface resistivity reduced solid, liquid or gaseous (ionized gas) additional foreign substances.

3.6.6 Pollution degree (in the micro-environment) polutiondegree (inthemicro-environment) To determine the clearances and creepage distances, the pollution degree microenvironment as the following three grades.

Note 1. The build-up of foreign matter and moisture can cause conductive insulator contamination.

Note 2. The minimum clearances for pollution degree Pollution Degree 2 and 3 are given based on experience rather than raw data.

3.6.6.1 Pollution Level 1 polutiondegree

1 No pollution or only dry non-conductive pollution, the pollution has no adverse effect. [GB 4793.1-2007, the definition 3.6.6.1]

3.6.6.2 Pollution Level 2 polutiondegree

2 Normally only non-conductive pollution, but occasionally due to condensation and short conductive.

3.6.6.3 Pollution Level 3 polutiondegree

3 Conductive pollution or dry non-conductive pollution which becomes conductive due to condensation.

Note. In this condition, the device is usually to prevent exposure to direct sunlight, rain, strong wind pressure, but it need not control the temperature or humidity.

3.6.7 Clearance clearance Space the shortest distance between two conductive parts. According to GB/T 16935.1-2008 provisions in 1.3.2.

3.6.8 Creepage distance creepagedistance Along the shortest distance between two conductive insulating solid surface material parts. [GB 4793.1-2007, the definition 3.6.8]

4 Test

4.1 Overview GB 30439 in this section All tests are type tests on the sample or parts of the transmitter carried out. These tests The only purpose is to examine whether the design and construction to ensure compliance with this requirement. In addition, the manufacturer shall produced at the same time dangerous LIVE parts and ACCESSIBLE conductive parts or components of transmitter 100% for routine tests specified in Appendix F. To satisfy the provisions of this Part and the relevant standards according to these requirements for use of the transmitter subassembly, the entire transmitter test pattern You do not have to repeat the test during the test. It should be checked by all applicable test meets the requirements of this section, but if the examination of the transmitter can really prove certainly pass Had a trial, then this test may be omitted. Test under the following conditions.

--- Reference test conditions (see 4.3);

--- Fault conditions (see 4.4). NOTE. If performing compliance test, or a measured value of the applied (such as voltage) of the actual value due to errors and uncertainty, then.

--- Manufacturer to ensure that the value of the test is applied to at least a predetermined value;

--- Test departments should ensure that the test applied is not greater than the value specified.

4.2 Test procedure Subject to the provisions of this section, the test sequence may be optionally substituted. After each trial to test the transmitter should be carefully checked. in case Test results have doubts, doubts if the test reverse the order of the trial whether any of the preceding pass true, the front of these tests It should be repeated. If the test will damage the transmitter under fault conditions, these tests can be placed under the test conditions of the reference test after that.

4.3 reference test conditions

4.3.1 Environmental Conditions Except as otherwise provided in this section, test sites shall meet the following conditions.

a) Temperature. 15 °C ~ 35 °C;

b) Relative humidity. not exceed 75%;

c) Atmospheric pressure. 75kPa ~ 106kPa;

d) no frost, condensation, water seepage, rain and sunshine.

4.3.2 transmitter status Unless otherwise specified, each test should be assembled on the transmitter can be used normally, and most of the provisions in 4.3.2.1 ~

4.3.2.8 Conducted under unfavorable combination of conditions. It should be required to the manufacturer's instructions for installation.

4.3.2.8 Output For providing an electrical output of the transmitter. Working condition

a) of the transmitter should be able to provide the rated output power of the rated load;

b) to any output, rated load impedance should be connected or not.

4.4 Test under single fault conditions

4.4.1 Overview It should be according to the following requirements.

a) Check the circuit diagram of the transmitter and can usually determine whether there is likely to cause dangerous fault conditions and therefore whether it should be applied;

b) In addition to proof of a specific fault conditions likely to cause danger, the test shall be the fault;

c) The transmitter shall operate at reference test conditions (see 4.3) the most unfavorable combination of conditions, for different faults, which combined strip Member can vary, these combined conditions should be recorded during each test.

4.4.2 Fault conditions imposed Fault conditions 4.4.2.1 ~

4.4.2.6 should include provisions for fault conditions. These fault conditions can only be applied to one and should press Sequentially applied in any convenient order, can not be applied more than one fault at the same time, the results unless it is applied to a fault caused by a fault. After each applied once the fault condition, the transmitter or parts shall pass the applicable test 4.4.4.

4.4.2.1 Impedance protection

a) If the impedance protection is a combination of components to form, it should be shorted or open each component, choose one of the more not Lee's.

b) If the impedance protection by basic insulation and current limiting or pressure-limiting devices to form, the basic insulation and current limiting pressure limiting device, or both Caught should afford a single fault condition, once applied to a fau...

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 52 pages — is available in the English PDF.

Referenced standards

Normative references

GB/T 1633-2000 · GB/T 3098.1-2000 · GB/T 3098.3-2000 · GB/T 4207-2003 · GB 4208-2008 · GB 4793.1-2007 · GB/T 7354-2003 · GB 9364.1-1997 · GB 9364.2-1997 · GB 9364.3-1997 · GB 9364.4-2006 · GB/T 11020-2005 · GB/T 11021-2007 · GB/T 11918-2001 · GB/T 11919-2001 · GB/T 12113-2003 · GB 14048.1-2006 · GB 14048.3-2008 · GB/T 16842-2008 · GB/T 16927 · GB/T 16935.1-2008 · GB/T 16935.3-2005 · IEC 60027

Similar standards

Editions of GB 30439.3

EditionTitleRevisionStatus
GB 30439.3-2013Safety requirements for industrial automation products-Part 3: Safety requirements for temperature transmittercurrent editionCurrent

This page sells the current edition, GB 30439.3-2013. Earlier editions are listed for reference only.

How to Buy GB 30439.3-2013

  1. 1Add to cart. Click the "Buy GB 30439.3-2013" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
52 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 30439.3-2013

$740.00

$630.00for partners