YY/T 1896-2023Method for defining the wavelength range of spectral radiation therapy equipment (English PDF)
光谱辐射治疗设备波长范围界定方法
This is a limited preview
Buy now to download the full PDF (7 pages)
Need quotation for your management?
Get a formal quotation for YY/T 1896-2023 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
June 20, 2023
Implementation date
July 1, 2024
Scope
YY/T 1896-2023 is the English-translated version of 光谱辐射治疗设备波长范围界定方法.
YY/T 1896-2023 is the Chinese standard "Method for defining the wavelength range of spectral radiation therapy equipment". Its scope clause reads: This document specifies the method for defining the wavelength range of spectral radiation therapy equipment (hereinafter referred to as "phototherapy equipment").
This document is suitable for clinical use of incoherent light including visible light, infrared light, ultraviolet light and other wavelengths from 180nm to 3000nm.
Treatment equipment. Its clauses include normative reference documents; terms and definitions.
Found what you need?
Document preview — YY/T 1896-2023
National Standard of the People's Republic of China
- ICS
- 11.040.60
- Classification
- C42
Issued by: National Medical Products Administration
Contents
- Preface
- 1 Scope
- 2 Normative reference documents
- 3 Terms and Definitions
- 4 Wavelength range definition method
- 5 Principles for using wavelength range definition method
1 Scope
This document specifies the method for defining the wavelength range of spectral radiation therapy equipment (hereinafter referred to as "phototherapy equipment").
This document is suitable for clinical use of incoherent light including visible light, infrared light, ultraviolet light and other wavelengths from 180nm to 3000nm.
Treatment equipment.
2 Normative reference documents
This document has no normative references.
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 RMS spectrum width
Under standard working conditions, the spectrum is approximated by the Gaussian function Plambda. If sigmarms is the RMS spectrum width value, then.
sigma2rms=
%00
lambda-lambda0 2Plambda dlambda
%00
Plambdadlambda
In the formula.
lambda ---Light source wavelength;
lambda0 ---Central wavelength;
Plambda ---spectral intensity at wavelength lambda.
Note. The RMS spectrum width is equivalent to the weighted average spectrum width, which can more accurately reflect the spectral characteristics.
3.2
-3dBspectralwidth-3dBspectralwidth
Under standard operating conditions, the wavelength interval between two points of the spectral line where the amplitude of the peak wavelength of the main longitudinal mode drops by half, where -3dB=
10lg(1/2).
3.3
-20dBspectralwidth-20dBspectralwidth
Under standard operating conditions, the amplitude of the peak wavelength of the main longitudinal mode drops by 20dB by the wavelength interval between two points of the spectral line, where
-20dB=10lg(1/100).
3.4
The relative intensity of the spectrum is the wavelength range between the two wavelength points with the largest distance corresponding to a specific ratio of its peak.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.
How to Download YY/T 1896-2023
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY/T 0297-2026 — General requirements for clinical investigation of medical devices
YY/T 0479-2026 — Medical diagnostic X-ray tube assemblies and X-ray source assemblies - Determination of maximum symmetric radiation field
YY/T 0492-2026 — Implantable leads
Secure payment via Stripe
Payments accepted
YY/T 1896-2023
$150.00