YY 0900-2013Walk training platform with suspension (English PDF)
减重步行训练台
This is a limited preview
Buy now to download the full PDF (20 pages)
Need quotation for your management?
Get a formal quotation for YY 0900-2013 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Mandatory
Issue date
October 21, 2013
Implementation date
October 1, 2014
Scope
YY 0900-2013 is the English-translated version of 减重步行训练台.
YY 0900-2013 is the Chinese pharmaceutical industry standard for the walk training platform with suspension, the frame in which a patient's weight is partly taken by a harness while gait is retrained.
It specifies the terms, the definitions, the classification, the requirements, the test methods, the inspection rules, the marking, the operating instructions and the rules for packaging, transport and storage, covering the suspension force and its adjustment and accuracy, the strength and stability of the frame and of the harness, the walking surface or treadmill where fitted, the emergency stop and the electrical safety. Issued on 21 October 2013, it has applied since 1 October 2014.
Found what you need?
Document preview — YY 0900-2013
National Standard of the People's Republic of China
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword3
- 1 Scope4
- 2 Normative References4
- 3 Terms and Definitions4
- 4 Classification5
- 5 Requirements5
- 6 Test Methods8
- 7 Inspection Rules11
- 8 Marking and Operation Instruction12
- 9 Packaging, Transportation and Storage14
Foreword
This Standard was drafted in accordance with the rules in GB/T 1.1-2009.
The safety requirements in this Standard comprehensively implement the content in GB 9706.1-2007 Medical Electrical Equipment - Part 1: General Requirements for Safety.
In terms of all equipment or components whose materials or structural forms are different from what is stipulated in this Standard, if it can be proved that they reach an equivalent safety level, they shall be approved.
Please be noted that certain content in this document might involve patents. The institution that issues this document shall not undertake any responsibility of identifying these patents.
1 Scope
This Standard specifies the terms, definitions, classification, requirements, test methods, inspection rules, marking, operation instruction, packaging, transportation and storage of walk training platform with suspension (hereinafter referred to as equipment). This Standard is applicable to equipment stipulated in 3.1.
2 Normative References
The following documents are indispensable to the application of this Standard. In terms of references with a specified date, only versions with a specified date are applicable to this Standard. The latest version (including all the modifications) of references without a specified date is also applicable to this Standard.
GB/T 191 Packaging - Pictorial Marking for Handling of Goods
GB 9706.1-2007 Medical Electrical Equipment - Part 1: General Requirements for Safety
GB 9706.15 Medical Electrical Equipment - Part 1: General Requirements for Safety - 1.Collateral Standard. Safety Requirements for Medical Electrical Systems
GB/T 14710 Environmental Requirement and Test Methods for Medical Electrical Equipment
3 Terms and Definitions
Those defined in GB 9706.1-2007 AND the following terms and definitions are applicable to this document.
3.1 Walk Training Platform with Suspension
Walk training platform with suspension refers to medical electric-driven rehabilitation equipment, which is constituted of frame for suspension and walk training platform.
3.3 Walk Training Platform
Walk training platform is an auxiliary device for patients' walk training; it is generally electric-driven.
4 Classification
In accordance with whether the frame for suspension is movable, the equipment can be classified into stationary and movable.
5 Requirements
5.1 Frame for Suspension
5.1.1 Lifting stroke
Frame for suspension's lifting stroke shall satisfy the requirements stipulated by the manufacturer; the deviation shall not be more than ± 5%.
5.1.5 Suspension belt
5.1.5.1 Adjustment and locking
The suspension belt shall be equipped with adjustment and locking device, and easily operable. Locking shall be safe and reliable; easily recognizable and safely operated.
It shall be manually operated without the help of any instruments.
5.2 Walk Training Platform
5.2.1 Timing setting
The walk training platform shall have timing function; the timing error shall not be more than ± 1% of the set value, and not more than ± 1 min at the maximum.
5.2.3 Gradient setting
In terms of walk training platform which has the function of gradient adjustment, gradient shall be continuously adjustable. It shall also have the function of adjustment indication; the deviation of gradient indication shall not exceed ± 10%.
5.2.4 Static load
The walk training platform shall be able to maintain intact after supporting 6 times of the normal load stipulated by the manufacturer.
5.2.5 Safety of unexpected power outage
As power supply recovers after unexpected power outage, the walk training platform would not automatically operate.
5.2.6 Emergency stop device
Except from the power switch, the equipment shall also provide an emergency stop button, which can stop the training program at any time. This button shall take effect with just one action. This emergency stop button shall also be set up in a position accessible to patients during their training.
5.3 Overall Requirements of Equipment
5.3.1 Stability
The whole equipment shall have smooth landing; the difference between the footing and the horizontal plane shall not be more than 2 mm. In addition, during usage, the equipment shall not waggle or generate any displacement; the angle of overturn shall not be less than 10°. After reliably positioning it, there shall be no displacement.
5.3.2 Operating noise
During normal operation, the noise of the equipment shall not be more than 60 dB (A- weighted).
5.4 Operation Instruction
The operation instruction shall satisfy the requirement in 6.8.2 in GB 9706.1-2007. Meanwhile, it shall also include the following content.
5.5 Safety Requirements
The equipment shall satisfy the requirement in GB 9706.1-2007.
If it is operated under medical electrical system, the equipment shall satisfy the requirement in GB 9706.15.
5.6 Environmental Test Requirements
The equipment's environmental test shall be conducted in accordance with the stipulation in GB/T 14710.
6 Test Methods
6.1 Frame for Suspension
6.1.1 Lifting stroke
Respectively adjust the lifting stroke to the lowest end and the highest end. Measure its height; it shall comply with the requirement in 5.1.1.
6.1.5 Suspension belt
6.1.5.1 Adjustment and locking device
Conduct the test in practical operation; it shall comply with the requirement in 5.1.5.1.
6.1.5.2 Width
Conduct the test in practical measurement; it shall comply with the requirement in 5.1.5.2.
6.2 Walk Training Platform
6.2.1 Timing setting
Select an appropriate timing, which shall not be less than 30 min; if the maximum set timing is less than 30 min, select the maximum set timing. Conduct the test in practical measurement; it shall comply with the requirement in 5.2.1.
6.2.3 Gradient setting
Conduct the test in practical operation and measurement; it shall comply with the requirement in 5.2.3.
6.2.4 Static load
Conduct the test in accordance with the requirement in 6.6 in GB 17498.6-2008; it shall comply with the requirement in 5.2.4.
6.2.5 Safety of unexpected power outage
Conduct the test in practical operation; it shall comply with the requirement in 5.2.5.
6.2.6 Emergency stop device
Conduct the test in visual inspection and practical operation; it shall comply with the requirement in 5.2.6.
6.2.7 Fatigue test
In the test, simulate the equipment's moving components in 100,000 times of no-load operation. After that, the equipment's function shall still satisfy the requirement in 5.2.7.
6.3 Overall Requirements of Equipment
6.3.1 Stability
Place the overall equipment on a flat surface; use a feeler gauge to measure the distance between the footing and the flat surface.
6.3.2 Operating noise
Place the equipment on a hard table and at a distance of at least 3 m from the walls or other reflectors. Under the environment where background noise is 10 dB lower than the measuring point in the sound pressure level, operate the equipment under normal working state where the maximum noise might be generated; measure A-weighted sound level in the front, the back, the left, the right and the top of the host device of the equipment; they shall all satisfy the requirement in 5.3.2. If the manufacturer stipulates equipment's special installation or arrangement conditions in the attached documents, the equipment can be arranged merely in accordance with the method stipulated by the manufacturer.
6.5 Safety Requirements
Conduct the test through visual inspection and practical operation; it shall comply with the requirement in 5.5.
6.6 Environmental Test Requirements
Conduct the test through visual inspection and practical operation; it shall comply with the requirement in 5.6.
6.7 Biocompatibility
Consult relevant documents; it shall comply with the requirement in 5.7.
7 Inspection Rules
7.1 Inspection Classification
Equipment's quality inspection shall be classified into exit-factory inspection and type inspection.
7.3 Type Inspection
7.3.1 Type inspection shall be conducted under one of the following circumstances.
7.3.2 Determination of type inspection. if products are qualified in all the inspection items, then, they shall be determined as qualified in type inspection. Otherwise, they shall be determined as unqualified in type inspection.
8 Marking and Operation Instruction
8.1 Marking
8.1.1 Nameplate marking
Nameplate shall be set up in an appropriate location on the equipment. Nameplate marking shall at least include the following content.
8.1.2 Marking on external packaging
When equipment has external packaging, it shall at least include the following markings.
8.1.3 Marking on product inspection conformity certificate
The marking on product inspection conformity certificate shall at least include the following content.
8.2 Operation Instruction
Operation instruction shall at least include the following content.
9 Packaging, Transportation and Storage
9.1 Packaging
9.1.1 Equipment shall be individually packed. The external packaging shall be able to prevent product from natural damage; packaging materials shall comply with the stipulation in the ordering contract.
9.1.5 Equipment shall have the following attached documents.
9.2 Transportation
Transportation requirements shall comply with the stipulation in the ordering contract.
9.3 Storage
Equipment shall be stored at the temperature of -40 °C ~ 55 °C; relative humidity shall not exceed 90%. Equipment shall be stored in well-ventilated interior, where there is no corrosive gas. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 191Graphical symbols marking for handling and storage of packages
- GB 9706.1-2007Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
- GB 9706.15Medical electrical equipment -- Part 1: General requirements for safety. 1 -- Collateral standard: Safety requirements for medical electrical systems
- GB/T 14710The environmental requirement and test methods for medical electrical equipment
Similar standards
How to Download YY 0900-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 9706.15-2008 — Medical electrical equipment -- Part 1: General requirements for safety. 1 -- Collateral standard: Safety requirements for medical electrical systems
GB/T 14710-2009 — The environmental requirement and test methods for medical electrical equipment
GB/T 191-2025 — Graphical symbols marking for handling and storage of packages
Secure payment via Stripe
Payments accepted
YY 0900-2013
$125.00