YY/T 1787-2021Cardiovascular implants—Cardiac valve repair devices and delivery system (English PDF)
心血管植入物 心脏瓣膜修复器械及输送系统
This is a limited preview
Buy now to download the full PDF (63 pages)
Need quotation for your management?
Get a formal quotation for YY/T 1787-2021 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
September 6, 2021
Implementation date
September 1, 2022
Scope
YY/T 1787-2021 is the English-translated version of 心血管植入物 心脏瓣膜修复器械及输送系统.
YY/T 1787-2021 is the Chinese standard "Cardiovascular implants—Cardiac valve repair devices and delivery system". Its scope clause reads: This standard specifies the operating conditions and performance requirements for heart valve repair devices and their delivery systems, if applicable.
This standard applies to all repairs and/or modifications intended to act on valvular structures or adjacent anatomical structures (e.g., ventricles, coronary sinus).
Heart valve repair devices that improve the function of human native heart valves (for example. valvuloplasty devices, leaflet clamping devices, artificial tendons Sow, etc.).
This standard does not apply to cardiac resynchronization therapy (CRT) devices, paravalvular leak closure devices, and non-implantable systems (eg, ablation, radiofrequency valvuloplasty), apical catheters and instruments with living cell-containing components.
Nor is the standard suitable for the intended use not repaired and/or modified Materials that improve the function of human heart valves (eg. mesh materials and sutures for general surgery).
Note 1.YY/T 0640 specifies general requirements for the performance of passive surgical implants, this standard can be regarded as a supplement to YY/T 0640. Note 2.This standard outlines a risk management approach to verify/validate the design and manufacture of heart valve repair systems.
Choose the appropriate Validation/validation tests and methods. Such tests include evaluation of the physical, chemical, biological and mechanical properties of the components and materials of the heart valve repair system.
Evaluate. The trial also includes a preclinical in vivo evaluation of the finished heart valve repair system to assess the safety and efficacy of the heart valve repair system. effectiveness. Note 3.Appendix A gives the rationale for the terms of this standard.
Found what you need?
Document preview — YY/T 1787-2021
National Standard of the People's Republic of China
- ICS
- 11.040.40
- Classification
- C 35
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Abbreviations
- 5 Basic requirements
- 6 Device Description
- 7 Design Verification Experiments and Analysis/Design Validation
- Appendix A (informative appendix) Principles of the provisions of this standard
- Appendix B (Informative) Hazards, Relevant Failure Modes, and Evaluation Methods of Heart Valve Repair Systems
- Appendix C (Informative) Guidelines for In Vitro Testing of Pediatric Devices
- Appendix D (Normative Appendix) Packaging
- Appendix E (Normative Appendix) Product Labels, Instructions for Use and Training
- Appendix F (Normative Appendix) Sterilization
- Appendix G (Informative) Characteristics of Heart Valve Repair Systems
- Appendix I (Informative) Standard Examples for Testing Materials and Components for Heart Valve Repair Devices
- Appendix J (informative) Considerations for changes in device material properties after implantation
- Appendix K (informative) Corrosion Assessment
- Appendix L (Informative Appendix) Guidelines for In Vitro Evaluation of Restorative Functional Performance
- Appendix M (Informative) Fatigue Assessment
- Appendix N (Informative Appendix) Durability Test
- Appendix O (Informative) Guidelines for Design Evaluation of Delivery Systems
- Appendix P (Informative) Additional Device Design Evaluation Requirements
- Appendix Q (Informative) Preclinical In Vitro Performance Evaluation of Annuloplasty Rings
- Appendix R (Informative) Preclinical In Vivo Evaluation
1 Scope
This standard specifies the operating conditions and performance requirements for heart valve repair devices and their delivery systems, if applicable.
This standard applies to all repairs and/or modifications intended to act on valvular structures or adjacent anatomical structures (e.g., ventricles, coronary sinus).
Heart valve repair devices that improve the function of human native heart valves (for example. valvuloplasty devices, leaflet clamping devices, artificial tendons
Sow, etc.).
This standard does not apply to cardiac resynchronization therapy (CRT) devices, paravalvular leak closure devices, and non-implantable systems (eg, ablation, radiofrequency valvuloplasty), apical catheters and instruments with living cell-containing components. Nor is the standard suitable for the intended use not repaired and/or modified
Materials that improve the function of human heart valves (eg. mesh materials and sutures for general surgery).
Note 1.YY/T 0640 specifies general requirements for the performance of passive surgical implants, this standard can be regarded as a supplement to YY/T 0640.
Note 2.This standard outlines a risk management approach to verify/validate the design and manufacture of heart valve repair systems. Choose the appropriate
Validation/validation tests and methods. Such tests include evaluation of the physical, chemical, biological and mechanical properties of the components and materials of the heart valve repair system.
Evaluate. The trial also includes a preclinical in vivo evaluation of the finished heart valve repair system to assess the safety and efficacy of the heart valve repair system.
effectiveness.
Note 3.Appendix A gives the rationale for the terms of this standard.
2 Normative references
The following documents are essential for the application of this document. For dated references, only the dated version applies to this article pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 16886.1 Biological Evaluation of Medical Devices Part 1.Evaluation and Testing in Risk Management Process (GB/T 16886.
1-2011, ISO 10993-1.2009, IDT)
GB/T 16886.2 Biological Evaluation of Medical Devices Part 2.Animal Welfare Requirements (GB/T 16886.2-2011, ISO 10993-2.2006, IDT)
GB 18278.1 Moist heat for sterilization of health care products - Part 1.Requirements for the development, validation and routine control of the sterilization process for medical devices
Seek (GB 18278.1-2015, ISO 17665-1.2006, IDT)
GB 18279.1 Sterilization of Healthcare Products Ethylene Oxide Part 1.Development, Validation and Routine Control of Sterilization Processes for Medical Devices requirements (GB 18279.1-2015, ISO 11135-1.2007, IDT)
GB 18280 (all parts) Sterilizing radiation for healthcare products [ISO 11137 (all parts)]
GB/T 19633 (all parts) Packaging for terminally sterilized medical devices [ISO 11607 (all parts)]
GB/T.19974 Characterization of Sterilization Factors for Sterilization of Healthcare Products and Development, Validation and Routine Control of Sterilization Processes for Medical Devices
General requirements for (GB/T.19974-2018, ISO 14937.2009, IDT)
YY/T 0287 Medical device quality management system for regulatory requirements (YY/T 0287-2017, ISO 13485.2016,
IDT)
YY/T 0316-2016 Application of Medical Device Risk Management to Medical Devices (ISO 14971.2007 Corrected Edition, IDT) […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 63 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 16886.1Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
- GB/T 16886.2Biological evaluation of medical devices - Part 2: Animal welfare requirements
- GB 18278.1Sterilization of health care products - Moist heat - Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices
- GB 18279.1Sterilization of health care products—Ethylene oxide—Part 1: Requirements for development,validation and routine control of a sterilization process for medical devices
- GB/T 19974Sterilization of health care products -- General requirement for characterization of a sterilization agent and the development, validation and routine control of a sterilization process for medical devices
- YY/T 0287Medical devices-Quality management systems- Requirements for regulatory purposes
GB 18280 (all parts) · GB/T 19633 (all parts)
Similar standards
How to Download YY/T 1787-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 18278.1-2015 — Sterilization of health care products - Moist heat - Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices
GB 18279.1-2015 — Sterilization of health care products—Ethylene oxide—Part 1: Requirements for development,validation and routine control of a sterilization process for medical devices
GB/T 16886.1-2022 — Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
Secure payment via Stripe
Payments accepted
YY/T 1787-2021
$1,040.00