YY/T 1925-2024Cardiovascular implants and endovascular devices - Neurovascular thrombectomy stent retrievers (English PDF)
心血管植入器械 神经血管取栓支架
Open the YY/T 1925-2024 preview as PDF
This is a limited preview
Buy now to download the full PDF (25 pages)
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
February 7, 2024
Implementation date
March 1, 2025
Scope
YY/T 1925-2024 is the English-translated version of 心血管植入器械 神经血管取栓支架.
YY/T 1925 is the product standard for the neurovascular stent retriever, the device that has transformed the treatment of acute ischaemic stroke by pulling the clot out of a cerebral artery. It specifies the general requirements, the intended performance, the design attributes, the materials, the laboratory design evaluation, the post-market surveillance, the manufacture, the sterilisation and the packaging. That breadth is deliberate: a retriever is deployed into a clot, embedded in it and withdrawn through tortuous intracranial vessels, so clot integration, retrieval force, radiopacity and resistance to fracture matter together, and post-market data is treated as part of the evidence rather than an afterthought. For a manufacturer or an importer seeking Chinese registration, this is the governing standard.
Document preview — YY/T 1925-2024
National Standard of the People's Republic of China
- ICS
- 11.040.40
- Classification
- C45
Issued by: National Medical Products Administration
Contents
- 1 Scope1
- 2 Normative references1
- 3 Terms and Definitions1
- 4 General requirements2
- 5 Expected Performance3
- 6 Design attributes3
- 7 Materials3
- 8 Laboratory Design Evaluation3
- 9 Post-marketing surveillance6
- 10 Manufacturing6
- 11 Sterilization6
- 9 Reference21
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part
1.Structure and drafting rules for standardization documents" Drafting. Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document is proposed by the State Food and Drug Administration. This document was prepared by the National Technical Committee for Standardization of Surgical Implants and Orthopedic Devices, Cardiovascular Implants Subcommittee (SAC/ TC110/SC2) is responsible for this. This document was drafted by: Tianjin Medical Device Quality Supervision and Inspection Center, National Medical Products Administration Medical Device Technical Review Center Center, National Medical Products Administration Medical Device Technical Review and Inspection Greater Bay Area Center, Aike Medical Devices (Beijing) Co., Ltd., Jiangsu Nuanyang Medical Equipment Co., Ltd. The main drafters of this document are. Zhang Zhenghui, Ma Jinzhu, Jiao Yongzhe, Qiao Jiaqi, Zhu Lili, Cheng Maobo, Mu Lanlan, Lian Xiaoqi, Chen Yibei, Lü Yiran, Gao Hongliang, and Sun Bing. Cardiovascular implantable device Neurovascular thrombectomy stent
1 Scope
YY/T 1925 is the product standard for the neurovascular stent retriever, the device that has transformed the treatment of acute ischaemic stroke by pulling the clot out of a cerebral artery. It specifies the general requirements, the intended performance, the design attributes, the materials, the laboratory design evaluation, the post-market surveillance, the manufacture, the sterilisation and the packaging. That breadth is deliberate: a retriever is deployed into a clot, embedded in it and withdrawn through tortuous intracranial vessels, so clot integration, retrieval force, radiopacity and resistance to fracture matter together, and post-market data is treated as part of the evidence rather than an afterthought. For a manufacturer or an importer seeking Chinese registration, this is the governing standard.
This document specifies the general requirements, expected performance, design attributes, materials, laboratory Requirements for design evaluation, post-market surveillance, manufacturing, sterilization, and packaging. This document applies to thrombectomy procedures intended to remove thrombi from the nerve vessels of patients with ischemic stroke, thereby restoring vascular blood flow. Bracket. This document does not apply to other instruments and/or accessories that may be used in thrombectomy, such as balloon catheters, microguidewires, microcatheters, etc.
Note. YY/T 1747 specifies the general requirements for the performance of intracranial artery stents. If the manufacturer expects that the thrombectomy stent may be dislodged intracranially, it is recommended that the stent be left in place as an implant. In patients, refer to the relevant requirements for intracranial artery stents.
2 Normative references
The contents of the following documents constitute the essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document.
GB/T 16886.1 Biological evaluation of medical devices Part
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 determine A quantitative assessment or analysis.
3.2 evaluate Qualitative assessment or analysis.
7 Ethylene oxide sterilization residues
GB 18278.1 Sterilization of health care products by moist heat Part
1.Development, validation and routine control of sterilization processes for medical devices Require
GB 18279.1 Sterilization of healthcare products with ethylene oxide Part
1.Development, validation and routine control of sterilization processes for medical devices Requirements
GB 18280.1 Radiation sterilization of health care products Part
1.Development, validation and routine control of sterilization processes for medical devices Require
GB/T 19633.1 Terminally sterilized medical device packaging Part
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 25 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 16886.1Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
- GB 18280.1Sterilization of health care products - Radiation - Part 1: Requirements for the development
- YY/T 0640Non-active surgical implants - General requirements
GB/T 16886.7 · GB 18278.1 · GB 18279.1 · GB/T 19633.1 · GB/T 19633.2 · GB/T 42062 · YY 0450.1-2020
Similar standards
YY/T 1680|YY/T 1561|YY/T 1571|YY/T 1274
How to Buy YY/T 1925-2024
- 1Add to cart. Click the "Buy YY/T 1925-2024" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 18280.1-2025 — Sterilization of health care products - Radiation - Part 1: Requirements for the development
GB/T 16886.1-2022 — Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
GB/T 16886.10-2024 — Biological evaluation of medical devices - Part 10: Tests for skin sensitization