YY/T 0895-2013Commissioning of radiotherapy treatment planning systems - Testing for typical external beam treatment techniques (English PDF)
放射治疗计划系统的调试典型外照射治疗技术的测试
This is a limited preview
Buy now to download the full PDF (33 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0895-2013 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
October 21, 2013
Implementation date
October 1, 2014
Scope
YY/T 0895-2013 is the English-translated version of 放射治疗计划系统的调试典型外照射治疗技术的测试.
YY/T 0895-2013 is the Chinese pharmaceutical industry standard that gives the typical test methods for commissioning a radiotherapy treatment planning system for external beam therapy.
It applies to the commissioning and the testing of such a system for high energy photon beam techniques before it is put to clinical use, setting out the beam data to be measured and entered, the test cases and the geometries, the tolerances on the calculated dose and the records of the commissioning. Issued on 21 October 2013, it has applied since 1 October 2014.
Found what you need?
Document preview — YY/T 0895-2013
National Standard of the People's Republic of China
- ICS
- 11.040.60
- Classification
- C 43
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions GB/T 17857-1999, YY 0637-2008
- 4 Clinical commissioning tests
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
Introduction
Debugging is radiation treatment planning system (RTPS) and radiation treatment planning quality assurance (QA) is the most important part. debugging It includes a test RTPS function to record each dose and dose verification RTPS performance calculation is consistent actually measured.
YY/T 0798-2010 "Radiotherapy Planning System Quality Assurance Guide" provides a RTPS routine quality control (QC) overall Framework, the provisions of the RTPS regular quality assurance procedures for the implementation of quality assurance required content of the test, and gives the test frequencies Suggest. However, the implementation of YY/T 0798-2010 All test items requires a huge amount of work and requires a lot of manpower and equipment Resources.
This standard provides a limited number of test items, allowing users RTPS can be completed within a reasonable period of time, has a better "practical Sex. "These test items specified in this standard should help users avoid treatment planning process serious errors. Without reducing overall Under the premise of a large number of reduced quality assurance testing, to optimize and streamline RTPS RTPS suppliers and user acceptance testing in the RTPS When the test work.
Other content radiotherapy system quality assurance program is not covered by this standard, as well as other radiotherapy techniques, please refer
YY/T 0798-2010 "Radiotherapy Planning System Quality Assurance Guidelines" implementation.
1 Scope
This standard specifies the radiation treatment planning system (hereinafter referred to RTPS) debugging typical test method of external beam radiation therapy.
This standard applies to RTPS before being put into clinical use of external irradiation of high-energy photon beam therapy debugging and testing techniques.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 17857-1999 Medical imaging academic language (radiotherapy, nuclear medicine and radiation dosimetry equipment)
GB/T 18987-2003 Radiotherapy equipment Coordinates, movements and scales Safety requirements for medical electrical equipment YY 0637-2008 Radiation Treatment Planning System Accuracy requirements and test methods YY 0775-2010 long-distance high-energy radiation treatment planning system X (gamma) beam dose calculation
YY/T 0798-2010 quality assurance of radiation treatment planning systems guidelines
3 Terms and Definitions
GB/T 17857-1999, YY 0637-2008 terms and definitions YY/T 0798-2010 defined apply to this document.
4 Clinical commissioning tests
4.1 Overview
4.1.1 Acceptance Test
YY/T 0798-2010 provides for all features RTPS dose algorithm, algorithm validation and software testing, complete the standard gauge Given test content requires a huge amount of work, and beyond what most medical units to carry out radiotherapy capacity range. To this end, this standard Combined YY 0775-2010, recommend a limited number of tests to help medical units in the RTPS photon beam dose algorithm is applied clinical. RTPS user should clearly be used to treat function, provide reasonable input data, perform beam fitting for RTPS test A series of data collection and analysis, verification testing of dose algorithm then RTPS be put into clinical use.
By performing YY 0775-2010, the user can obtain the basic knowledge of RTPS dose algorithm and verify its accuracy. Test Acceptance tests completed by the RTPS together users and suppliers. Acceptance Test using a preset beam data, can prove to users field test can Achieve the same results with the type test.
4.1.2 Fitting beams
After the completion of the acceptance test shall be in accordance with the manufacturer's specifications measured data, and the data input beam systems fitted. By comparison The difference between the calculated and measured dose values and tolerances YY 0775-2010 given in Table 1, confirm the validity of the beam fitting program.
Test conditions shall contain a uniform water phantom in the open field, wild and irregular wedge field. Each algorithm will be put into clinical use must be completed
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 33 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download YY/T 0895-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 17857-1999 — Medical radiology. Terminology (Equipment for radiotherapy, nuclear medicine and radiation dosimetry)
YY/T 0798-2010 — Radiotherapy treatment planning system—Guidelines for quality assurance
YY/T 0297-2026 — General requirements for clinical investigation of medical devices