YY/T 1981-2025Radiotherapy treatment planning software - Requirement and test method for electron beam dose calculation accuracy (English PDF)

放射治疗计划软件 电子束剂量计算准确性要求和试验方法

Open the YY/T 1981-2025 preview as PDF

Preview — first pages of YY/T 1981-2025 (full document: 8 pages)

This is a limited preview

Buy now to download the full PDF (8 pages)

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

June 18, 2025

Implementation date

January 1, 2027

Scope

YY/T 1981-2025 is the English-translated version of 放射治疗计划软件 电子束剂量计算准确性要求和试验方法.

YY/T 1981 puts a number on how accurate a radiotherapy planning system has to be for electron beams. It specifies the requirements for the accuracy of electron beam dose calculation in radiotherapy treatment planning software, referred to as RTPS, and describes the corresponding test methods. It applies to planning software handling external beam electron radiotherapy. Electron beams behave differently from photons at tissue interfaces and near the surface, which is where dose calculation algorithms diverge most and where a planning error reaches the patient directly. The document takes effect on 1 January 2027. For a vendor of treatment planning systems seeking Chinese registration, or a hospital physics team commissioning one, this is the standard the electron dose accuracy verification is run against.

Document preview — YY/T 1981-2025

National Standard of the People's Republic of China

ICS
11.040.60
Classification
C43

Issued by: National Medical Products Administration

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 3.1 Dose calculated values [Source: YY 0775-2010, 3.1]
  • 4 Requirements
  • 4.1 Accuracy of dose calculation at measurement points along the radiation beam axis
  • 4.2 Accuracy of dose calculation at off-axis measurement points within the radiation field
  • 4.3 Accuracy of dose calculation at radiation field measurement points
  • 4.4 Accuracy of dose calculation at measurement points along the radiation beam axis
  • 4.5 Accuracy of distance calculation between isodose points
  • 4.6 Accuracy of Planar Dose Distribution Calculation
  • 5 Test Methods
  • 5.1 Experimental phantom and radiation detector
  • 5.2 Accuracy of dose calculation at measurement points along the radiation beam axis
  • 5.3 Accuracy of dose calculation at off-axis measurement points within the radiation field
  • 5.4 Accuracy of dose calculation at radiation field measurement points
  • 5.5 Accuracy of dose calculation at measurement points along the radiation beam axis
  • 5.6 Accuracy of distance calculation between isodose points

Foreword

This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part

1.Structure and Drafting Rules of Standardization Documents". Drafting. Please note that some content in this document may involve patents. The issuing organization of this document assumes no responsibility for identifying patents. This document was proposed by the National Medical Products Administration. This document was prepared by the Subcommittee on Radiotherapy, Nuclear Medicine and Radiation Dosimetry Equipment of the National Technical Committee for Standardization of Medical Electrical Appliances. (SAC/TC10/SC3) is under its jurisdiction. This document was drafted by: Beijing Institute for Medical Device Testing (Beijing Medical Biological Protective Equipment Testing and Research Center), Varian Medical... Medical Equipment (China) Co., Ltd., Peking University Cancer Hospital, Shanghai United Imaging Healthcare Co., Ltd., Elekta (Shanghai) Technology Co., Ltd. The company, Xi'an Dayi Group Co., Ltd., Sichuan University, the First Medical Center of the General Hospital of the Chinese People's Liberation Army, and Shanghai University of Science and Technology. The main drafters of this document are. Jiao Chunying, Zhang Xin, Wu Hao, Fu Guotao, Liu Yanfang, Ye Shaoqiang, Chen Shufei, Zhang Zhongyuan, Lin Angchun, and Gou Chengjun. Li Yueling, Xie Chuanbin, Liu Baolin, Yan Rongguo. Radiotherapy planning software Accuracy requirements and test methods for electron beam dose calculation

1 Scope

YY/T 1981 puts a number on how accurate a radiotherapy planning system has to be for electron beams. It specifies the requirements for the accuracy of electron beam dose calculation in radiotherapy treatment planning software, referred to as RTPS, and describes the corresponding test methods. It applies to planning software handling external beam electron radiotherapy. Electron beams behave differently from photons at tissue interfaces and near the surface, which is where dose calculation algorithms diverge most and where a planning error reaches the patient directly. The document takes effect on 1 January 2027. For a vendor of treatment planning systems seeking Chinese registration, or a hospital physics team commissioning one, this is the standard the electron dose accuracy verification is run against.

This document specifies the accuracy requirements for electron beam dose calculation in radiotherapy planning software (RTPS) and describes the corresponding experimental methods. This document applies to radiotherapy units with long-range electron beam dose calculation functions used in conjunction with medical electron accelerators. Software for slicing. This document is not applicable to electron beam radiotherapy planning software for specific applications.

2 Normative references

The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are not included. For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies. This document.

GB 9706.201 Medical Electrical Equipment - Part 2-

3 Terms and Definitions

The terms and definitions defined in GB 9706.201, GB 15213, GB/T 17857 and YY 0775, as well as the following terms and definitions, apply to this document.

3.1 Dose calculated values [Source: YY 0775-2010, 3.1]

3.2 nominal energy Provided by the manufacturer, it is used to characterize the energy of the radiation beam. [Source: GB 15213-2016, 3.13]

3.3 A beam-limiting device for electron radiation beams. [Source: GB 9706.201-2020,.201.3.203]

3.4 maximum dose depth The depth at which the maximum absorbed dose is located on the radiation beam axis within the phantom when the phantom surface is at a specific distance.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 8 pages — is available in the English PDF.

Referenced standards

Similar standards

YY/T 1694|YY/T 1711|YY/T 1537|YY/T 1625|YY/T 1973

How to Buy YY/T 1981-2025

  1. 1Add to cart. Click the "Buy YY/T 1981-2025" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
8 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 1981-2025

$260.00

$220.00for partners