YY/T 0889-2013Intensity-modulated radiation treatment planning system—Functional performance characteristics and test methods (English PDF)
调强放射治疗计划系统性能和试验方法
This is a limited preview
Buy now to download the full PDF (18 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0889-2013 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
October 21, 2013
Implementation date
October 1, 2014
Scope
YY/T 0889-2013 is the English-translated version of 调强放射治疗计划系统性能和试验方法.
YY/T 0889-2013 is the Chinese pharmaceutical industry standard for the intensity-modulated radiation treatment planning system.
It specifies the terms and definitions, the functional performance characteristics and the test methods, covering the optimisation and the way the objectives are set, the calculation of the fluence and its conversion into deliverable segments or leaf sequences, the accuracy of the dose calculation and the transfer and verification of the plan. Issued on 21 October 2013, it has applied since 1 October 2014.
Found what you need?
Document preview — YY/T 0889-2013
National Standard of the People's Republic of China
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword3
- 1 Scope4
- 2 Normative references4
- 3 Terms and Definitions5
- 4 Performance Requirements6
- 5 Test Methods6
- Annex A (Normative) Test Cases9
- Annex B (Informative) Test Data17
- Bibliography18
Foreword
This Standard is drafted according to the rules specified in GB/T 1.1-2009.
1 Scope
This Standard specifies the terms, definitions, performance requirements and test methods of intensity-modulated radiation treatment planning system.
2 Normative references
The articles contained in the following documents have become part of this Document when they are quoted herein. For the dated documents so quoted, all the modifications (Including all corrections) or revisions made thereafter shall be applicable to this document.
GB 9706.5 Medical electrical equipment - Part 2-1.Particular requirements for the safety of electron accelerators in the range 1 MeV to 50 MeV
3 Terms and Definitions
Those defined in GB 9706.5, GB 15213, GB/T 17857 and YY 0637 AND the following terms and definitions apply to this Standard.
The therapeutic dose that is given to target volume according to certain time dose splitting methods.
4 Performance Requirements
For each IMRT test case specified in Appendix A, DESIGN the treatment plan in accordance with the dose target specified in this Standard; REPORT the actual situations that meet dose target.
5 Test Methods
Treatment plan shall be designed according to the requirements as stated in Appendix A.
The conformance of dose target of each IMRT test case shall be checked. Dose target of test cases shall be satisfied as far as possible. Otherwise, the actual test data shall be provided for assessment, so as to determine whether the IMRT plan is acceptable.
Annex A (Normative)
Test Cases These test cases radiate die body through easily-designed fields. It is mainly used to verify the accuracy of system dose calculation prior to the design of IMRT treatment plan.
Annex B (Informative)
When designing treatment plan according to the test case requirements of Appendix A of this Document, the anatomical structure data in data package of AAPM TG119 technical report [1] is recommended to use. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download YY/T 0889-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 9706.5-2008 — Medical electrical equipment -- Part 2-1: Particular requirements for the safety of electron accelerators in the range 1 MeV to 50 MeV
YY/T 0297-2026 — General requirements for clinical investigation of medical devices
YY/T 0479-2026 — Medical diagnostic X-ray tube assemblies and X-ray source assemblies - Determination of maximum symmetric radiation field
Secure payment via Stripe
Payments accepted
YY/T 0889-2013