GB 9706.5-2008Medical electrical equipment -- Part 2-1: Particular requirements for the safety of electron accelerators in the range 1 MeV to 50 MeV (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (20 pages)

Need quotation for your management?

Get a formal quotation for GB 9706.5-2008 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

December 15, 2008

Implementation date

February 1, 2010

Scope

GB 9706.5-2008 (Medical electrical equipment -- Part 2-1: Particular requirements for the safety of electron accelerators in the range 1 MeV to 50 MeV) is available as an English-translated PDF.

GB 9706.5-2008 is the Chinese standard "Medical electrical equipment -- Part 2-1: Particular requirements for the safety of electron accelerators in the range 1 MeV to 50 MeV".

Its scope clause reads: This Part establishes requirements to ensure the IONIZING RADIATION safety and enhanced electrical and mechanical safety of ELECTRON ACCELERATORS, and specifies tests to check compliance with those requirements.

Its clauses include scope and object; terminology and definitions; general requirements for tests; classification replacement.; identification, marking and documents.

It was issued by the General Administration of Quality Supervision, Inspection and Quarantine on 2008-12-15 and took effect on 2010-02-01.

Found what you need?

Document preview — GB 9706.5-2008

National Standard of the People's Republic of China

ICS
11.040.60
Classification
C 43

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Foreword...4
  • Introduction...6
  • SECTION ONE - OVERVIEW...7
  • 1 Scope and Object...7
  • 2 Terminology and Definitions...10
  • 4 General Requirements for Tests...13
  • 5 Classification...14
  • 6 Identification, Marking and Documents...16
  • SECTION TWO - ENVIRONMENTAL CONDITIONS...20
  • 10 Environmental Conditions...20

Foreword

All the technical contents of this Part are mandatory.

The safety serial standards of Medical Electrical Equipment consist of the following

two parts.

--- Part 1.General Requirements for the Safety;

--- Part 2.Particular Requirements for the Safety.

This Part is the Particular Requirements for the Safety; which is the Part 5 of GB 9706.

This Part equivalently adopts IEC 60601-2-1.1998 Medical Electrical Equipment – Part

2-1.Particular Requirements for the Safety of Electron Accelerators in the Range

1MeV to 50MeV and its Amendment No.1.2002.

For the benefit of use, this Part made the following editorial modifications.

--- Delete the Foreword, Introduction and Annex BB of IEC 60601-2-1.1998 Medical

Electrical Equipment – Part 2-1.Particular Requirements for the Safety of

Electron Accelerators in the Range 1MeV to 50MeV; add this Foreword;

--- The Annex L of this Part is normative, thereof, the mentioned "Annex L in the

General Standard" refers to Annex L of GB 9706.1-2007.The Annex AA of this

Part is informative.

--- For other international standard quoted in the standard, if they have been

converted into Chinese standards, this Part replaces the corresponding

internationals standard number by the national standard number; the

corresponding relationship is listed in the Annex L.

This Part replaced GB 9706.5-1992 Medical Electrical Equipment – Particular

Requirements for the Safety of Medical Electron Accelerators in the Range 1MeV to

50MeV.

Compared with GB 9706.5-1992, this Part has the major technical changes as follows.

--- Use through combination of GB 9706.1-2007.According to the requirements of

this General Standard, this Part made the corresponding modifications;

--- Add the parallel standards, such as IEC 60601-1-14, YY 0505;

--- There are many revision and deletion against the marking requirements of the

control devices and instruments; such part contents in the original standard have

been included in GB/T 18987-2003;

--- Add the requirements for the instruction manual;

--- Make more revision and deletion against the requirements for the technical

specification;

--- Propose more detailed requirements for the moving parts;

--- Add and modify the requirements for ionizing radiation;

--- Equivalently adopt the content of Amendment No.1.2002 of IEC 62601-2-1.set

the leakage limit for the total limit beam system (see 29.3.1.1 of this Part in

details);

--- Add the requirements for the abnormal operation and fault conditions;

--- Delete the requirements for the components and assemblies;

--- Add and modify the drawing;

--- Add the Annex L (Informative).

The Annex L, Annex AA of this Part are informative.

This Part was proposed by China Food and Drug Administration.

This Part shall be under the jurisdiction of Technical Sub-Committee for

Standardization of Radiotherapy, Nuclear Medicine and Radiopharmaceutical

Equipment of National Technical Committee for Standardization of Medical Electrical

Equipment (SAC/TC 10/SC 3).

Drafting organization of this Part. Beijing Institute of Medical Device Testing.

Chief drafting staffs of this Part. Liu Yi, Sun Zhuohui, Wang Peichen, and Song Lianyou.

This Part was first-time published in November of 1992; this time is the first-time

revised.

1 Scope and Object

This Part establishes requirements to ensure the IONIZING RADIATION safety and

enhanced electrical and mechanical safety of ELECTRON ACCELERATORS, and

specifies tests to check compliance with those requirements.

2 Terminology and Definitions

Term used where the features of a system can be modified only by physically removing

and re-routing wires.

For a particular design of device or EQUIPMENT, test by the MANUFACTURER to

establish compliance with SPECIFIED criteria.

4 General Requirements for Tests

Three grades of TYPE TEST and two of SITE TEST procedures are SPECIFIED in

clause 29 of this Particular Standard. Their requirements are as follows.

5 Classification Replacement.

EQUIPMENT and its APPLIED PARTS shall be classified by marking and/or

identification as described in clause 6.This includes.

6 Identification, Marking and Documents

Where the requirements of this item are wholly or partly met by the nature of the

installation, compliance at installation should be checked by inspection; the results

should be included in the SITE TEST report.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.

Referenced standards

How to Download GB 9706.5-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
20 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 9706.5-2008

$280.00