YY/T 0727.2-2009Implants for surgery - Metal intramedullary nailing systems - Part 2: Locking components (English PDF)

外科植入物 金属髓内钉系统 第2部分:锁定部件

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for YY/T 0727.2-2009 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

November 25, 2009

Implementation date

December 1, 2010

Scope

YY/T 0727.2-2009 is the English-translated version of 外科植入物 金属髓内钉系统 第2部分:锁定部件.

YY/T 0727.2-2009, identical to ISO 15142-2:2003, is Part 2 of the Chinese pharmaceutical industry series on metal intramedullary nailing systems, and deals with the locking components that secure a nail inside a long bone.

It classifies these locking parts and sets their requirements, drawing on the general rules for non-active surgical implants and osteosynthesis implants, on bone screw dimensions and on the GB/T 16886 series for biological evaluation.

It covers metal devices placed in the medullary canal for temporary fixation of human long bones, but not nails that are used without interlocking. The other parts of the series address the nails themselves and the instruments for connection, reaming and canal diameter measurement. Issued on 25 November 2009, it has applied since 1 December 2010.

Found what you need?

Document preview — YY/T 0727.2-2009

National Standard of the People's Republic of China

ICS
11.040.40
Classification
C 35

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references

Foreword

YY/T 0727 "surgical implants metal intramedullary nail system" is divided into three parts.

--- Part 1. intramedullary nail;

--- Part 2. locking member;

--- Part 3. Connect the instrument to expand the canal and diameter measurements. This section YY/T Section 20727 of.

This part identical with ISO 15142-2:2003 "surgical implants metal nail systems - Part 2. locking member." For ease of use, this section made the following editorial changes.

a) "this International Standard" be replaced by "this section";

b) the normative references have been converted to equivalent national standards or industry standards with international standards with national standards or industry standards instead;

c) Remove the foreword and introduction of international standards.

This part of the National Surgical implants and orthopedic instruments Standardization Technical Committee (SAC/TC110) centralized.

This section is drafted. Tianjin State Food and Drug Administration Medical Device Quality Supervision and Inspection Center.

1 Scope

YY/T 0727 provisions of this part of the way by a surgical implant for temporary fixation within the bone marrow long metal medical devices. Given Classification and requirements intramedullary nail locking member.

This section applies to all human long bone intramedullary temporary fixing metal fixation devices. This section does not apply to non-interlocking intramedullary nail.

2 Normative references

The following documents contain provisions which, through reference YY/T 0727 to the present, constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.

GB/T 12417.1 active surgical implants bone and joint replacement implants - Part 1. Particular requirements for osteosynthesis implants (GB/T 12417.1-2008, ISO 14602:1998, IDT)

GB/T 16886.3 Biological evaluation of medical devices - Part 3. Tests for genotoxicity, carcinogenicity and reproductive toxicity (GB/T 16886.3-2008, ISO 10993-3:2003, IDT)

GB/T 16886.4 Biological evaluation of medical devices - Part 4. Selection of tests for interactions with blood (GB/T 16886.4-2003, ISO 10993-4:2002, IDT)

GB/T 16886.5 Biological evaluation of medical devices - Part 5. In vitro cytotoxicity test (GB/T 16886.5-2003, ISO 10993-5:1999, IDT)

Qualitative and quantitative framework for potential degradation products. GB/T 16886.9 Biological evaluation of medical devices - Part 9 (GB/T 16886.9-2001, ISO 10993-9:1999, IDT)

GB/T 16886.10 Biological evaluation of medical devices - Part 10. irritation and delayed-type hypersensitivity test (GB/T 16886.10-2005, ISO 10993-10:2002, IDT)

GB/T 16886.13 Biological evaluation of medical devices - Part 13. qualitative and quantitative degradation products from polymeric medical devices (GB/T 16886.13-2001, ISO 10993-13:1998, IDT)

GB/T 16886.14 Biological evaluation of medical devices - Part 14. Ceramic degradation products of qualitative and quantitative (GB/T 16886.14-2003, ISO 10993-14:2001, IDT)

GB/T 16886.15 Biological evaluation of medical devices - Part 15. degradation products from metals and alloys qualitative and quantitative (GB/T 16886.15-2003, ISO 10993-15:2000, IDT)

GB/T 16886.16 Biological evaluation of medical devices - Part 16. degradation products and leachables Toxicokinetic study design (GB/T 16886.16-2003, ISO 10993-16:1997, IDT)

GB/T 16886.17 Biological evaluation of medical devices - Part 17. leachables allow the establishment of a limited amount of (GB/T 16886.17-2005, ISO 10993-17:2002, IDT)

YY/T 0316 Medical Devices Risk Management for Medical Device Applications (YY/T 0316-2008, ISO 14971-1:2007, IDT)

YY/T 0640 General requirements for passive surgical implants (YY/T 0640-2008, ISO 14630:2005, IDT)

ISO 5835 (all parts) surgical implant metal bone screw size

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Normative references

ISO 5835

Similar standards

How to Download YY/T 0727.2-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0727.2-2009

$75.00