Valid

YY/T 0019.2-2011Implants for surgery-Intramedullary nailing systems - Part 2: Medullary pins (English PDF)

外科植入物 髓内钉系统 第2部分:髓内针

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for YY/T 0019.2-2011 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

December 31, 2011

Implementation date

June 1, 2013

Scope

YY/T 0019.2-2011 is the English-translated version of 外科植入物 髓内钉系统 第2部分:髓内针.

YY/T 0019.2-2011 is the Chinese pharmaceutical industry standard that fixes the main dimensions of the medullary pin used as an orthopaedic implant, together with the requirements it must meet.

It is the second part of the YY/T 0019 series on intramedullary nailing systems and covers the diameters and the lengths and their tolerances, the form of the ends and the surface of the pin. Issued on 31 December 2011, it has applied since 1 June 2013.

Found what you need?

Document preview — YY/T 0019.2-2011

National Standard of the People's Republic of China

ICS
11.040.40
Classification
C 35

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Materials
  • 4 Manufacturing method
  • 5 Surface
  • 6 Dimensions

Foreword

YY/T 0019 "surgical implant intramedullary nail system" is divided into two parts.

--- Part 1. trilobal cross section or V-shaped intramedullary nail;

--- Part 2. intramedullary nail. This section YY/T 0019 Part 2. This section drafted in accordance with GB/T 1.1-2009 given rules.

From "surgical implant intramedullary nail system" from the implementation date, replace and repeal YY 0019-2002 "metal implant intramedullary osteosynthesis Needle ", may, according to this standard and YY 0341" to develop the products of enterprises with non-active surgical osteosynthesis metal implants general technical conditions " standard.

The main difference between "surgical implant intramedullary nail system" and YY 0019-2002 "osteosynthesis implant intramedullary nail metal" as follows.

--- The standard by "trilobal cross-section of the intramedullary nail" instead YY 0019-2002 in "Plum needle";

--- The standard by "intramedullary nail" instead YY 0019-2002 of "crochet";

--- This standard adds the V-nail type, delete YY 0019-2002 double rectangular flexible wire, flexible wire circular arcuate Needle, curved needle, needle and wing needle, such as several types of intramedullary nail;

--- Compared with YY 0019-2002, the provisions of this standard intramedullary nail and needle the size of the relevant parts in more detail;

--- This standard adds and remove the hook with intramedullary nail used in the respective guide pin size.

This section uses the translation method identical with ISO 5837-2. 1980 "surgical implant intramedullary nail system Part 2. intramedullary nail." This part of ISO 5837-2. 1980 technical differences are as follows.

--- On normative references, this part has been adjusted technical differences, in order to adapt our technical conditions, the adjusted situation Focus is reflected in the status of Chapter 2, "Normative references", the specific adjustments are as follows.

- with GB 4234 instead of ISO 5832-1;

- with YY/T 0605.5 instead of ISO 5832-5;

- The latest version of the ISO (ISO 3651:1998) 3651-2 replaces the ISO 3651-2. 1976, the standard name be adjusted accordingly;

- increase the GB/T 321, and replaces the ISO 3.

--- Delete international standards foreword.

1 Scope

This section YY/T 0019 specifies the main dimensions of orthopedic implants and requirements of the intramedullary nail.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 321 priority number and priority number system (GB/T 321-2005, ISO 3. 1973, IDT)

GB 4234 stainless steel surgical implants (GB 4234-2003, ISO 5832-1:1997, MOD)

YY/T 0605.5 surgical implants of metallic materials - Part 5. Wrought cobalt - chromium - tungsten - nickel alloy (YY/T 0605.5-2007, ISO 5832-5:2005, IDT)

ISO 3651-2 Determination of stainless steel to intergranular corrosion - Part 2. Ferritic, austenitic and ferritic - austenitic (duplex) stainless Steel in sulfuric acid medium corrosion test (Determinationofresistancetointergranularcorrosionofstainless steels-Part 2. Ferritic, austeniticandferritic-austenitic (duplex) stainlesssteels-Corrosiontestin mediacontainingsulfuricacid)

3 Materials

Intramedullary nail may be consistent with GB 4234 stainless steel or in compliance with YY/T 0605.5 wrought cobalt - chromium - tungsten - nickel alloy (cold) manufacture.

According to the above requirements, the manufacturer of the intramedullary nail material should comply with GB 4234 or YY/T 0605.5 prescribed use.

4 Manufacturing method

Intramedullary nail should be used cold-drawn or cold manufacturing process, shall not be welded. If you need some parts of stainless steel intramedullary nail re plastic Shape, only when the whole of the final product to meet the ISO 3651-2 predetermined intergranular corrosion test before allowing the product locally heated.

5 Surface

The outer surface should be free of burrs, scratches and other visible defects. Special attention should be part of the intramedullary nail bending r surface quality.

6 Dimensions

The size of the intramedullary nail shown in Figure 1, shall comply with the requirements in Table 1.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download YY/T 0019.2-2011

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0019.2-2011

$85.00