GB/T 16886.5-2017Biological evaluation of medical devices -- Part 5: Tests for in vitro cytotoxicity (English PDF)
Also coversGBT16886.5-2017
Open the GB/T 16886.5-2017 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
AQSIQ; SAC
Level / Type
National · Recommended
Issue date
December 29, 2017
Implementation date
July 1, 2018
Scope
GB/T 16886.5-2017 (Biological evaluation of medical devices -- Part 5: Tests for in vitro cytotoxicity) is available as an English-translated PDF.
GB/T 16886.5-2017 — This Part of GB/T 16886 describes test methods to assess the in vitro cytotoxicity of medical devices. This Part specifies the incubation of cultured cells in contact with a device and/or extracts of a device either directly or through diffusion.
Document preview — GB/T 16886.5-2017
National Standard of the People's Republic of China
Issued by: AQSIQ; SAC
Contents
- Foreword...3
- Introduction...6
- 1 Scope...7
- 2 Normative references...7
- 3 Terms and definitions...7
- 4 Sample and control preparation...9
- 5 Cell lines...12
- 6 Culture medium...13
- 7 Preparation of cell stock culture...13
- 8 Test procedures...13
- 9 Test report...19
- 10 Assessment of results...20
- Annex A (informative) Neutral red uptake (NRU) cytotoxicity test...21
- Annex B (informative) Colony formation cytotoxicity test...30
- Annex C (informative) MTT cytotoxicity test...36
- Annex D (informative) XTT cytotoxicity test...42
- Bibliography...48
Foreword
GB/T 16886 "Biological evaluation of medical devices" consists of the following
parts.
- Part 1.Evaluation and testing within a risk management process;
- Part 2.Animal welfare requirements;
- Part 3.Tests for genotoxicity, carcinogenicity and reproductive toxicity;
- Part 4.Selection of tests for interactions with blood;
- Part 5.Tests for in vitro cytotoxicity;
- Part 6.Tests for local effects after implantation;
- Part 7.Ethylene oxide sterilization residuals;
- Part 9.Framework for identification and quantification of potential
degradation products;
- Part 10.Tests for irritation and skin sensitization;
- Part 11.Tests for systemic toxicity;
- Part 12.Sample preparation and reference materials;
- Part 13.Identification and quantification of degradation products from
polymeric medical devices;
- Part 14.Identification and quantification of degradation products from
ceramics;
- Part 15.Identification and quantification of degradation products from
metals and alloys;
- Part 16.Toxicokinetic study design for degradation products and leachables;
- Part 17.Establishment of allowable limits for leachable substances;
- Part 18.Chemical characterization of materials;
- Part 19.Physicochemical, morphological and topographical
characterization of materials;
- Part 20.Principles and methods for immunotoxicology testing of medical
devices.
This Part is Part 5 of GB/T 16886.
This Part is drafted in accordance with the rules given in GB/T 1.1-2009.
This Part replaces GB/T 16886.5-2003 "Biological evaluation of medical
devices - Part 5.Test for in vitro cytotoxicity". Compared with GB/T 16886.5-
2003, the main technical changes are as follows.
- MODIFY the relevant content of "preparation of liquid extracts of material",
"test procedures" and "assessment of results", and GIVE the qualitative and
quantitative evaluation indicators of cytotoxicity (see 4.2, Clause 8 and
Clause 10 of this Part, 4.2, Clause 8 and Clause 10 of 2003 edition);
- ADD the neutral red uptake (NRU) cytotoxicity test (see Annex A);
- ADD the colony formation cytotoxicity test (see Annex B);
- ADD the MTT cytotoxicity test (see Annex C);
- ADD the XTT cytotoxicity test (see Annex D).
This Part uses the translation method to be identical to ISO 10993-5.2009
"Biological evaluation of medical devices - Part 5.Test for in vitro cytotoxicity".
The documents of China that have a consistent correspondence with the
international documents referenced in this Part are as follows.
GB/T 16886.1-2011 Biological evaluation of medical devices - Part 1.
Evaluation and testing within a risk management process (ISO 10993-1.2009,
IDT)
GB/T 16886.12-2017 Biological evaluation of medical devices - Part 12.
Sample preparation and reference materials (ISO 10993-12.2012, IDT)
This Part was proposed by China Food and Drug Administration.
This Part shall be under the jurisdiction of National Technical Committee on
Biological Evaluation of Medical Devices of Standardization Administration of
China (SAC/TC 248).
Drafting organizations of this Part. China Food and Drug Administration Jinan
Quality Supervision and Inspection Center for Medical Devices, China Food
and Drug Administration Beijing Quality Supervision and Inspection Center for
Medical Devices, Jiangsu Institute of Medical Device Testing, Shanghai
Biomaterials Research and Testing Center.
Main drafters of this Part. Hou Li, Sun Xiaoxia, Wang Rui, He Xueying, Gao
Jingxian, Wang Shasha, Sun Jiao, Huang Xhewei.
The previous versions of the standards replaced by this Part are.
- GB/T 16886.5-1997;
- GB/T 16886.5-2003.
1 Scope
This Part of GB/T 16886 describes test methods to assess the in vitro
cytotoxicity of medical devices.
This Part specifies the incubation of cultured cells in contact with a device
and/or extracts of a device either directly or through diffusion.
2 Normative references
The following referenced documents are indispensable for the application of
this document. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any
amendments) applies.
ISO 10993-1 Biological evaluation of medical devices - Part 1.Evaluation
and testing within a risk management system
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 10993-1 and the following apply.
3.1
culture vessels
Vessels appropriate for cell culture including glass petri dishes, plastic culture
flasks or plastic multiwells and microtitre plates.
4 Sample and control preparation
4.1 General
The test shall be performed on
a) an extract of the test sample; and/or
b) the test sample itself.
5 Cell lines
Established cell lines are preferred and where used shall be obtained from
recognised repositories.
Where specific sensitivity is required, primary cell cultures, cell lines and
organotypic cultures obtained directly from living tissues shall only be used if
reproducibility and accuracy of the response can be demonstrated.
6 Culture medium
The culture medium shall be sterile.
The culture medium with or without serum shall meet the growth requirements
of the selected cell line.
7 Preparation of cell stock culture
Using the chosen cell line and culture medium, prepare sufficient cells to
complete the test. If the cells are to be grown from cultures taken from storage,
remove the cryoprotectant, if present.
8 Test procedures
8.1 Number of replicates
A minimum of three replicates shall be used for test samples and controls.
8.2 Test on extracts
8.2.1 This test allows both qualitative and quantitative assessment of
cytotoxicity.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
ISO 10993
Cited by
- GB/T 45481-2025Silicone rubber compounds for medical catheters
- GB/T 46661-2025Magnetic beads performance detection methods for cell separation
- YY/T 1670.2-2025Neurotoxicity evaluation of medical devices - Part 2: Tests for neuro-cytotoxicity
- GB/T 44666-2024Finger orthoses
- GB/T 44831-2024General technical requirements of skin-on-a-chip
- GB 19083-2023Protective face masks for medical use
How to Buy GB/T 16886.5-2017
- 1Add to cart. Click the "Buy GB/T 16886.5-2017" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 16886.1-2022 — Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
GB/T 16886.10-2024 — Biological evaluation of medical devices - Part 10: Tests for skin sensitization
GB/T 16886.15-2022 — Biological evaluation of medical devices - Part 15: Identification and quantification of degradation products from metals and alloys
Secure payment via Stripe
Payments accepted
GB/T 16886.5-2017
$440.00