YY/T 0690-2008Clinical laboratory testing and in vitro medical devices—Requirements for in vitro monitoring systems for self-testing of oral anticoagulant therapy (English PDF)
临床实验室测试和体外医疗器械 口服抗凝药治疗自测体外监测系统的要求
This is a limited preview
Buy now to download the full PDF (38 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0690-2008 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
October 17, 2008
Implementation date
January 1, 2010
Scope
YY/T 0690-2008 is the English-translated version of 临床实验室测试和体外医疗器械 口服抗凝药治疗自测体外监测系统的要求.
YY/T 0690-2008 is the Chinese standard "Clinical laboratory testing and in vitro medical devices—Requirements for in vitro monitoring systems for self-testing of oral anticoagulant therapy".
Its scope clause reads: This standard specifies the vitamin K antagonist therapy in vitro measurement systems to monitor their own specific requirements, including performance, quality assurance and the use of User training and performance by the intended user verification and validation in real conditions of use and simulation program.
This standard applies to the individual to monitor their own personal use vitamin K antagonist therapy and to report the results of PT INR measurement system.
This standard applies to oral anticoagulants in vitro monitoring system manufacturers and other organizations responsible for the performance evaluation of the system (such as regulators Bodies and conformity assessment bodies).
This standard does not --- Suitable for in vitro measurement system by a doctor or medical personnel to vitamin K antagonist anticoagulant therapy dose assessment; --- Providing affect system performance comprehensive evaluation of all possible factors; --- Oral anticoagulant therapy to solve the problem of medicine.
Found what you need?
Document preview — YY/T 0690-2008
National Standard of the People's Republic of China
- ICS
- 11.100.20
- Classification
- C 44
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 6 Design and Development
- 4.1 General requirements
- 4.2 Measurement Period
- 4.3 Security
- 4.4 Risk Management
- 4.6 Quality Assurance and Risk Control
- 4.7 Metrological traceability of
- 5.1 General requirements
- 5.2 monitor oral anticoagulant flag
- 5.3 Use of oral anticoagulation monitoring system Description
- 5.4 Reagents and signs of controlled substances
- 5.5 Reagents and use of controlled substances a description
- 6 safety and reliability testing
- 6.1 General requirements
- 6.2 Protection against electric shock
- 6.3 against mechanical damage
- 6.4 Electromagnetic Compatibility
- 6.5 Heat
- 6.6 resistant to moisture and liquids
- 6.8 Instrument assembly
- 6.9 Performance Test
- 6.10 resistance to mechanical shock, vibration and impact
- 6.11 Temperature exposure limits
- 6.12 exposed to humidity test program
- 6.13 Test reagent storage and use
- 7 Training and Education program
- 7.2 patients and other users of education
- 8 System Performance Verification
- 8.1 Overview
- 8.3 System Performance Verification Experiment
- 8.4 verify the precision of measurement
- 8.5 verify the accuracy of the system
- 8.6 minimum acceptable system accuracy
- 9 user performance evaluation
- 9.1 Overview
- 9.2 22 experimental sites
- 9.3 22 subjects
- 9.4 Instrument and material
- 9.5 User Proficiency Assessment
- 9.6 acceptance criteria and data evaluation
- Annex B (informative) Example 26 traceability chain
- Annex E (informative) oral anticoagulation monitoring system for quality assurance elements
- Annex F (informative) release oral anticoagulation monitoring system performance evaluation standard application form
- References
1 Scope
This standard specifies the vitamin K antagonist therapy in vitro measurement systems to monitor their own specific requirements, including performance, quality assurance and the use of
User training and performance by the intended user verification and validation in real conditions of use and simulation program.
This standard applies to the individual to monitor their own personal use vitamin K antagonist therapy and to report the results of PT INR measurement system.
This standard applies to oral anticoagulants in vitro monitoring system manufacturers and other organizations responsible for the performance evaluation of the system (such as regulators
Bodies and conformity assessment bodies).
This standard does not
--- Suitable for in vitro measurement system by a doctor or medical personnel to vitamin K antagonist anticoagulant therapy dose assessment;
--- Providing affect system performance comprehensive evaluation of all possible factors;
--- Oral anticoagulant therapy to solve the problem of medicine.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB 4793.1 measurement, control and laboratory safety requirements for electrical equipment Part 1. General requirements (GB 4793.1-
2007, IEC 61010-1.2001, IDT)
GB/T 17626.2 Electromagnetic compatibility Testing and measurement techniques - Electrostatic discharge immunity test (GB/T 17626.2-2006,
IEC 61000-4-2.2001, IDT)
GB/T 17626.3 electromagnetic compatibility test and measurement technology RFEMS test (GB/T 17626.3-
2006, IEC 61000-4-3.2002, IDT)
GB/T 18268 for measurement, control and laboratory use electrical equipment electromagnetic compatibility requirements (GB/T 18268-2000, IEC 61326-1.
1997, IDT)
GB/T 21415 in vitro diagnostic medical devices - Measurement of quantities in biological samples calibration and control materials assigned metrological traceability
Sex (GB/T 21415-2008, ISO 17511.2003, IDT)
YY/T 0287 medical device quality management system for regulatory requirements (YY/T 0287-2003, ISO 13485.2003, IDT)
YY/T 0316 Medical Devices Risk Management in Medical Devices (YY/T 0316-2003, ISO 14971.2000, IDT)
ISO 15198 Clinical Laboratory Medicine in vitro diagnostic medical device manufacturers quality control program for user authentication
ISO 18113-1. 1) Clinical laboratory testing and in vitro diagnostic medical systems manufacturer's information (label) - Part 1. surgery
Language, definitions and general requirements
ISO 18113-4. 1) Clinical laboratory testing and in vitro diagnostic medical systems manufacturer's information (label) - Part 4. Self
Measured using an in vitro diagnostic reagents
ISO 18113-5. 1) Clinical laboratory testing and in vitro diagnostic medical system manufacturers to provide information (labeling) - Part 5. Self
Measured in vitro diagnostic instruments
1) to be published.
YY/T 0690-2008/ISO 17593.2007 […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 38 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 4793.1Safety requirements for electrical equipment for measurement,control,andlaboratory use-Part 1:General requirements
- GB/T 17626.2Electromagnetic compatibility -- Testing and measurement techniques -- Electrostatic discharge immunity test
- GB/T 17626.3Electromagnetic compatibility - Testing and measurement techniques - Part 3: Radiated, radio-frequency, electromagnetic field immunity test
- GB/T 21415In vitro diagnostic medical devices - Requirements for establishing metrological traceability of values assigned to calibrators, trueness control materials and human samples
- YY/T 0287Medical devices-Quality management systems- Requirements for regulatory purposes
- YY/T 0316Medical devices-Application of risk management to medical devices
GB/T 18268 · ISO 15198 · ISO 18113-1 · ISO 18113-4 · ISO 18113-5
Similar standards
How to Download YY/T 0690-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 4793.1-2007 — Safety requirements for electrical equipment for measurement,control,andlaboratory use-Part 1:General requirements
GB/T 17626.2-2018 — Electromagnetic compatibility -- Testing and measurement techniques -- Electrostatic discharge immunity test
GB/T 17626.3-2023 — Electromagnetic compatibility - Testing and measurement techniques - Part 3: Radiated, radio-frequency, electromagnetic field immunity test
Secure payment via Stripe
Payments accepted
YY/T 0690-2008
$590.00