YY 0600.3-2007Lung ventilators for medical use—Particular requirements for basic safety and essential performance - Part 3: emergency and transport ventilators (English PDF)
医用呼吸机 基本安全和主要性能专用要求 第3部分:急救和转运用呼吸机
This is a limited preview
Buy now to download the full PDF (20 pages)
Need quotation for your management?
Get a formal quotation for YY 0600.3-2007 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Mandatory
Issue date
January 31, 2007
Implementation date
February 1, 2008
Scope
YY 0600.3-2007 is the English-translated version of 医用呼吸机 基本安全和主要性能专用要求 第3部分:急救和转运用呼吸机.
YY 0600.3-2007 is Part 3 of the Chinese pharmaceutical industry series on lung ventilators, modified from ISO 10651-3:1997 and dealing with the portable ventilators used in emergencies and during patient transport.
Built as a particular standard on GB 9706.1, it adds requirements on marking and instructions for use, alarms, protection against electric shock, mechanical and radiation hazards, electromagnetic compatibility, environmental tests with the ambient temperature range, accuracy of operating data and prevention of hazardous output.
The devices it addresses are often mounted in ambulances or other rescue vehicles but also carried by hand, and it extends to ventilators permanently installed in ambulances or aircraft.
Manual resuscitators are outside its scope. Issued on 31 January 2007, it has applied since 1 February 2008.
Found what you need?
Document preview — YY 0600.3-2007
National Standard of the People's Republic of China
- ICS
- 11.040.10
- Classification
- C 46
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- Introduction First article overview
- 1 Scope
- 2 Terms and definitions
- 3 General requirements
- 4 General requirements for testing
- 5 Classification
- 6 Identification, marking and documentation
- 7 Input power
- 8 Basic safety type
- 9 Removable protective device
- 10 Environmental Conditions
- 11 Not used
- 12 Not used
- 13 Overview
- 14 Requirements for classification
- 15 Limitation of Voltage and/or Energy
- 16 Housing and protective cover
- 17 Isolation
- 18 Protective earth, functional earth and potential equalization
- 19 Continuous leakage current and patient auxiliary current
- 20 Dielectric strength
- 21 Mechanical strength
- 222 Moving parts
- 23 Faces, corners and edges
- 24 Stability during normal use
- 25 Splash
- 26 Vibration and noise
- 27 Pneumatic and Hydraulic Power
- 28 Hanging objects
- 29 X-Ray Radiation
- 30 alpha, beta, gamma, neutron radiation and other particle radiation
- 31 microwave radiation
- 32 Light radiation (including laser radiation)
- 33 Infrared radiation
- 34 ultraviolet radiation
- 35 sound energy (including ultrasound)
- 36 Electromagnetic Compatibility
- 37 Location and basic requirements
- 38 mark, random file
- 39 Common requirements for AP and APG equipment
- 40 Requirements and tests for AP-type equipment and its parts and components
- 41 Requirements and tests for APG-type equipment and its parts and components Chapter 7 Protection against overtemperature and other dangers
- 42 over temperature
- 43 fire protection
- 44 Overflow, liquid spill, leak, dampness, ingress of liquid, cleaning, disinfection and sterilization
- 45 Pressure vessels and pressure parts
- 46 Human error
- 47 electrostatic charge
- 48 Materials for application parts in contact with the patient's body
- 49 Power supply interruption
- 50 Accuracy of working data
- 51 Prevention of Dangerous Outputs
- 52 Abnormal operation and fault status
- 53 Environmental Test
- 54 Overview
- 55 Housing and cover
- 56 Components and Assemblies
- 57 network power supply parts, components and wiring
- 58 Protective Earth --- Terminals and Connections
- 59 Structure and wiring
- Appendix
- Appendix AA (Informative) Basic Principles
- Appendix BB (informative) Reference
- Appendix CC (informative appendix) The chapter number in this part is compared with ISO 10651-3.:1997 chapter number YY 060.3-2007
Foreword
The general title of Y600 is "Special Requirements for Basic Safety and Main Performance of Medical Ventilators", which consists of the following parts.
--- Part 1. Household respiratory support equipment;
--- Part 2. Home ventilator for ventilator dependent patients;
--- Part 3. Respirators for emergency and transport. Other parts of Y600 will be formulated one after another.
--- Part 4. artificial breathing equipment;
--- Part 5. Pneumatic first aid resuscitation equipment.
This part is the third part of Y0600. It is modified to adopt the international standard ISO 10651-3.:1997 "Medical ventilator --- Part 3.
Specific requirements for ventilator for emergency and transfer ", the main differences between this part and ISO 10651-3.:1997 are as follows.
--- This section adjusts ISO 10651-2.:2004 Chapter 2 "Normative Reference Documents" to 1.101; Chapter 3 "Terms and Definitions" Adjusted to Chapter 2, consistent with the general standard number;
--- Article 10.2.1a) The ambient temperature range is modified to "unless stated otherwise by the manufacturer, the ambient temperature range is -18 ° C to + 50 ° C".
The main reason for revising this article is that it is difficult to implement this article at the current domestic level, but it is not appropriate to modify the original standard technology.
Technical parameters, so be sure to add "unless otherwise specified by the manufacturer" in this clause;
--- Article 36.202.2.1 was amended to "Unless the manufacturer indicates otherwise, the level will be changed from 3V/m to 30V/m". This article is amended The main reason is that the original standard requires an order of magnitude greater than general medical device products, making it difficult to achieve at the current domestic level.
Large, but it is not appropriate to modify the technical parameters of the original standard, so it is determined to add "unless stated otherwise by the manufacturer" in this clause Expression.
This section is based on GB 9706.1-2007 (IEC 60601-1. 1988 + Amd1..1991 + Amd2..1995, IDT) "Medical Electrical Equipment Part 1. Special requirements for general safety requirements (common standards), used in conjunction with GB 97.16.1, and with GB 976.1-2007 (IEC 60601-1. 1988 + Amd1..1991 + Amd2..1995, IDT) was implemented in the same period.
Chapter 36 of this part is juxtaposed with Z05505-2005 "Medical Electrical Equipment Part 1-2. General Safety Requirements Standard. Electromagnetic Compatibility-Requirements and Tests "implemented concurrently.
Appendix AA, Appendix BB, and Appendix CC of this section are informative appendices.
Introduction
This part of the Q600 is specific requirements for portable ventilator for emergency and transport. These devices must meet breathing Machine definitions (automatically augmenting or providing ventilation to a patient's lungs), but they are more often medically trained by people with varying degrees of training Out-of-hospital or home use.
This part of Y600 is a special standard based on GB 9701.1 "Medical Electrical Equipment Part 1. General Safety Requirements."
GB 970.1 is referred to herein as the "common standard." Common standards are all used or monitored by qualified personnel in general medical and patient environments The basic standard for the safety of medical electrical equipment, it also includes some requirements for reliable operation to ensure safety.
Common standards are used in combination with side-by-side and proprietary standards. Tiered standards include special technical and/or hazardous requirements and apply to all There are application equipment, such as medical systems, EMC, radiation protection for diagnostic X-ray equipment, software, etc. Specific standards apply to special equipment types, such as Such as medical electron accelerator, high frequency electric knife, hospital bed and so on.
For a description of the parallel and special standards, see GB 9.76.1-2007 in Chapter 1.5 and Chapter A2, respectively.
The numbering of chapters, chapters, and articles in this part of Y0600 is consistent with the general standards. Changes to the text of the General Standard and supplements to the Parallel Standard Charge, specified by using the following words.
--- "Replace" means that the chapter or section of the general standard is completely replaced by the text of this section.
--- "Additional" means that the relevant text in this section is new content (for example, bar, column item, note, table, figure) attached to the general standard.
--- "Modified" means that the existing content of the general standard has been partially modified.
In order to avoid confusion with the revised version of the General Standard itself, the chapters, bars, tables and figures added to this part of Q6000 are numbered starting from 101;
The supplementary columns are numbered by the letters aa) and bb); the supplementary appendixes are numbered by AA, BB, etc.
The clauses marked with an asterisk (*) in this section are described in Appendix AA.
2 Terms and definitions
Except for the following definitions, 1.3 of GB 9706.28-2006 and Chapter 2 of GB 9706.1-2007 apply.
The definition in 2.1.5 of GB 9706.1 should be modified as follows.
2.1.5 Applied part
The breathing apparatus is connected to the patient or any part of the respiratory system. Part of the equipment, during normal use.
--- The part in which the function must be in direct contact with the patient, or
--- the part that may be used to contact the patient; or
--- need to be touched by the patient, or
--- All parts that can be connected to the respiratory ventilation system.
Note: See instructions in Appendix AA.
1.3.19 High-pressure input port
The definition in GB 9706.28-2006, 1.19 should be amended to:
Gas inlet with a pressure greater than 500kPa.
Note: Please pay attention to the definition in GB/T 4999.
2.101 Emergency ventilator
The following definitions also apply.
It is mainly used for portable ventilator for respiratory rescue outside the hospital.
2.102 Breathing system filter
Equipment for reducing bacteria and particles in gas systems.
2.103 Neonatal
Related to infants weighing less than 5kg.
2.104 Resuscitator
Passive portable medical equipment that provides breathing for patients with impaired breathing in emergency situations.
2.105 Paediatric
It is related to children weighing between 5kg and 40kg.
2.106 Transport ventilator
A ventilator for transporting to and from a hospital and between patients.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2423.6-1995Environmental testing for electric and electronic products - Part 2: Test methods - Test Eb and guidance: Bump
- GB/T 2423.8-1995Environmental testing for electric and electronic products - Part 2: Test methods - Test Ed: Free fall
- GB/T 2423.10-1995Environmental testing - Part 2: Test methods - Test Fc: Vibration (sinusoidal)
- GB/T 4999-2003Anaesthetic and respiratory equipment Vocabulary
- GB/T 5332-1985Method of test for ignition temperature of flammable liquids and gases
- GB 9706.1Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
GB 7144-1999 · GB 9706.28-2006 · ISO 5356-2-1987 · ISO 5359-1989 · ISO 5362-1986 · ISO 9170-1990 · IEC 68-8-36
Similar standards
How to Download YY 0600.3-2007
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 9706.1-2020 — Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
GB/T 2423.6-1995 — Environmental testing for electric and electronic products - Part 2: Test methods - Test Eb and guidance: Bump
GB/T 2423.8-1995 — Environmental testing for electric and electronic products - Part 2: Test methods - Test Ed: Free fall
Secure payment via Stripe
Payments accepted
YY 0600.3-2007
$355.00