YY 0600.1-2007Lung ventilators for medical use -- Particular requirements for basic safety and essential performance - - Part 1: Home-care ventilatory support devices (English PDF)
医用呼吸机 基本安全和主要性能专用要求 第1部分:家用呼吸支持设备
This is a limited preview
Buy now to download the full PDF (42 pages)
Need quotation for your management?
Get a formal quotation for YY 0600.1-2007 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Mandatory
Issue date
January 31, 2007
Implementation date
February 1, 2008
Scope
YY 0600.1-2007 is the English-translated version of 医用呼吸机 基本安全和主要性能专用要求 第1部分:家用呼吸支持设备.
YY 0600.1-2007 is the Chinese pharmaceutical industry standard that sets the basic safety and essential performance requirements for home-care ventilatory support devices, the ventilators intended mainly for use at home but which may also be used elsewhere, in a healthcare facility for instance, for patients who do not need a home care ventilator complying with YY 0600.2.
It is the first part of the YY 0600 series and applies together with GB 9706.1-2007, whose clauses it replaces or modifies, covering the delivered ventilation and its accuracy, the alarms, the behaviour on failure of the power supply and the information supplied with the device. Issued on 31 January 2007, it has applied since 1 February 2008.
Found what you need?
Document preview — YY 0600.1-2007
National Standard of the People's Republic of China
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword5
- Introduction7
- 1 Scope9
- 2 Terms and definitions10
- 3 General requirements12
- 4 General requirements for tests13
- 5 Classification13
- 6 Identification, marking and documents13
- 7 Power input19
- 8 Basic safety categories19
- 9 Removable protective means19
- 10 Environmental conditions19
- 11 Not used20
- 12 Not used20
- 13 General20
- 14 Requirements related to classification20
- 15 Limitation of voltage and/or energy21
- 16 Enclosures and protective covers21
- 17 Separation21
- 18 Protective earthing, functional earthing and potential equalization21
- 19 Continuous leakage currents and patient auxiliary currents21
- 20 Dielectric strength21
- 21 Mechanical strength22
- 22 Moving parts22
- 23 Surfaces, corners and edges22
- 24 Stability in normal use22
- 25 Expelled parts22
- 26 Vibration and noise22
- 27 Pneumatic and hydraulic power22
- 28 Suspended masses22
- 29 X-ray radiation22
- 30 alpha, beta, gamma, neutron radiation and other particle radiation23
- 31 Microwave radiation23
- 32 Light radiation (including lasers)23
- 33 Infra-red radiation23
- 34 Ultra-violet radiation23
- 35 Acoustical energy (including ultrasonic)23
- 36 Electromagnetic compatibility23
- 37 Locations and basic requirements24
- 38 Marking, accompanying documents24
- 39 Common requirements for category AP and category APG equipment24
- 40 Requirements and tests for category AP equipment, parts and components thereof24
- 41 Requirements and tests for category APG equipment, parts and components thereof24
- 42 Excessive temperature24
- 43 Fire prevention24
- 44 Overflow, spillage, leakage, humidity, ingress of liquids, cleaning, sterilization, disinfection and compatibility25
- 45 Pressure vessels and parts subject to pressure27
- 46 Human errors27
- 47 Electrostatic charges27
- 48 Biocompatibility27
- 49 Interruption of the power supply27
- 50 Accuracy of the operating data28
- 51 Protection against hazardous output28
- 52 Abnormal operation and fault conditions30
- 53 Environmental tests31
- 54 General31
- 55 Enclosures and covers31
- 56 Components and general assembly31
- 57 Mains parts, components and layout34
- 58 Protective earthing - Terminals and connections34
- 59 Construction and layout34
- 101 Alarm systems34
- 102 Appendix of general standard34
- Appendix AA (Informative) Rationale36
- References42
Foreword
YY 0600 "Lung ventilators for medical use - Particular requirements for basic safety and essential performance" consists of the following components:
- Part 1: Home-care ventilatory support devices;
- Part 2: Home care ventilators for ventilator-dependent patients;
- Part 3: Emergency and transport ventilators. The following parts of YY 0600 are under preparation:
- Part 4: Operator-powered resuscitators;
- Part 5: Gas-powered emergency resuscitators.
This part is part 1 of YY 0600, which modifies and adopts the international standard ISO 10651-6:2004 "Lung ventilators for medical use - Particular requirements for basic safety and essential performance - Part 6: Home-care ventilatory support device" (English version). The main differences between this part and ISO 10651-6:2004 are as follows:
- In this part, adjust the clause 2 "Normative references" of ISO 10651-6:2004 into 1.101; adjust the clause 3 "Terms and definitions" into clause 2, in order to keep consistency with the number of general standard;
- In clause 46, it is modified into "do not adopt";
- In 56.3 bb), modify the connector of the high-pressure input port to comply with the provisions of Table 2 and Figure 3 of ISO 5359;
- DELETE the Appendix BB;
- The unit "hPa" in this part is converted to "kPa".
This part is a particular standard based on GB 9706.1-2007 (IEC 60601-1:1988 + Amd1:1991 + Amd2:1995, IDT) "Medical electrical equipment - Part 1: General requirements for safety", which is used in conjunction with GB 9706.1 AND implemented at the same time with GB 9706.1-2007 (IEC 60601-1:1988 + Amd1:1991 + Amd2:1995, IDT).
The clause 36 of this part is implemented at the same time with YY 0505-2005 "Medical electrical equipment - Part 1-2: General requirements for safety - Collateral standards: Electromagnetic compatibility - Requirements and tests".
1 Scope
GB 9706.1-2007, clause 1 applies, except as follows. Modification:
This part of YY 0600 specifies the basic safety and essential performance requirements for home-care ventilator support devices, intended mainly for use in home care BUT which could be used elsewhere (e.g. in healthcare facilities) for appropriate patients for whom the use of a home-care ventilator complying with YY 0600.2 is not required.
The requirements of this part of YY 0600 which replace or modify the requirements of the general standards are intended to take precedence over the corresponding general requirements.
1.101 Normative references
The provisions in following documents become the provisions of this part through reference in this part of YY 0600. For the dated references, the subsequent amendments (excluding corrections) or revisions do not apply to this Standard; however, parties who reach an agreement based on this Standard are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies.
GB/T 4999-2003 Anesthetic and respiratory equipment - Vocabulary (ISO 4135:2001, IDT)
GB/T 5332-1985 Method of test for ignition temperature of flammable liquids and gases (eqv IEC 60079-4:1975)
GB 7144-1999 Coloured cylinder mark for gases
GB 9706.1 Medical electrical equipment - Part 1: General requirements for safety (GB 9706.1-2007, IEC 60601-1:1988 + Amd1:1991 + Amd2:1995, IDT)
GB/T 19974-2005 Sterilization of health care products - General requirement for characterization of a sterilization agent and the development, validation and routine control of a sterilization process (ISO 14937:2000, IDT)
YY/T 0316-2003 Medical devices - Application of risk management to medical devices (ISO 14971:2000, IDT)
YY 0461-2003 Breathing tubes intended for use with aneasthetic apparatus and ventilators (ISO 5367:2000, IDT)
YY 0466-2003 Medical devices - Symbols to be used with medical device labels labelling and information to be supplied (ISO 15223:2000, IDT)
YY 0505-2005 Medical electrical equipment - Part 1-2: General requirements for safety Collateral standards: Electromagnetic compatibility - Requirements and tests (IEC 60601-1-2:2001, IDT)
YY 1040.1-2003 Anesthetic and respiratory equipment - Conical connectors - Part 1: Cones and sockets (ISO 5356-1:1996, IDT)
ISO 5356-2 Anesthetic and respiratory equipment - Conical connectors - Part 2: Screw-threaded weight-bearing connectors
ISO 5359 Anesthetic and respiratory equipment - Low-pressure hose assemblies for use with medical gases
ISO 5362 Anesthetic reservoir bags
ISO 7396-1 Medical gas pipeline systems - Part 1: Pipeline systems for compressed medical gases and vacuum
ISO 15001 Anesthetic and respiratory equipment - Compatibility with oxygen
IEC 60601-1-8:2003 Medical electrical equipment - Part 1-8: General requirements for safety - Collateral standard: Alarm systems - Requirements, tests and guidelines - General requirements and guidelines for alarm systems in medical electrical equipment and medical electrical systems
2 Terms and definitions
For the purposes of this document, the terms and definitions given in GB/T 4999-2003, GB 9706.1 AND the following terms and definitions apply to this part of YY 0600. Addition: […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 42 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 4999-2003Anaesthetic and respiratory equipment Vocabulary
- GB/T 5332-1985Method of test for ignition temperature of flammable liquids and gases
- GB 9706.1Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
- GB/T 19974-2005Sterilization of health care products -- General requirement for characterization of a sterilization agent and the development, validation and routine control of a sterilization process for medical devices
- YY/T 0316-2003Medical devices-Application of risk management to medical devices
- YY 0461-2003Breathing tubes intended for use with anaesthetic apparatus and ventilators
GB 7144-1999 · ISO 5356-2 · ISO 5359 · ISO 5362 · ISO 7396-1 · ISO 15001 · IEC 60601-1-8:2003
Similar standards
How to Download YY 0600.1-2007
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 9706.1-2020 — Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
GB/T 4999-2003 — Anaesthetic and respiratory equipment Vocabulary
YY 0461-2003 — Breathing tubes intended for use with anaesthetic apparatus and ventilators
Secure payment via Stripe
Payments accepted
YY 0600.1-2007
$125.00