Scope

SJ/T 11141-2017 (Generic specification for LED displays) is available as an English-translated PDF.

SJ/T 11141-2017 is the Chinese standard "Generic specification for LED displays". Its scope clause reads: This Standard specifies the method for the determination of methanol content in developer for the electronics industry by headspace gas chromatography method.

This Standard is applicable to the determination of methanol content in developer for the electronics industry. The minimum detection concentration of methanol in this method is 1 mg/kg.

Its clauses include terms and definitions; principle of method; apparatus; test; detection limit of the method. It was issued by the Ministry of Industry and Information Technology of PRC on 2016-04-05 and took effect on 2016-09-01.

Found what you need?

Document preview — SJ/T 11141-2017

National Standard of the People's Republic of China

ICS
31.030
Classification
L 90

Issued by: Ministry of Industry and Information Technology of PRC

Contents

  • Foreword...3
  • 1 Scope...4
  • 2 Normative References...4
  • 3 Terms and Definitions...4
  • 4 Principle of Method...4
  • 5 Reagents and Materials...5
  • 6 Apparatus...6
  • 7 Test...6
  • 8 Precision and Results...7
  • 9 Detection Limit of the Method...8
  • 10 Spike Recovery Rate...9
  • 11 Report...9

1 Scope

This Standard specifies the method for the determination of methanol content in developer for the electronics industry by headspace gas chromatography method.

This Standard is applicable to the determination of methanol content in developer for the electronics industry. The minimum detection concentration of methanol in this method is 1 mg/kg.

2 Normative References

The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this document.

GB/T 602 Chemical Reagent - Preparations of Standard Solutions for Impurity

GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods

GB/T 9722 Chemical Reagent - General Rules for the Gas Chromatography

3 Terms and Definitions

For the purpose of this document, the terms and definitions given in GB/T 9722 apply.

4 Principle of Method

In a closed bottle, at a certain temperature, methanol molecules escape from the liquid phase to the gas phase. After a certain period of time, the methanol molecules reach a dynamic equilibrium between the gas and liquid phases. At this time, the concentration of methanol in the gas phase is proportional to its concentration in the liquid phase. The methanol in the gas phase is separated by a capillary column and detected by a hydrogen flame ionization detector. The retention time is qualitative, and

6 Apparatus

6.1 Gas chromatograph

Hydrogen flame ionization detector (FID) and data processing system.

6.2 Headspace sample-injecting device

Headspace sampler or other equivalent devices.

6.3 Headspace bottle

Commonly used volume is (22±0.5) mL; lined with polytetrafluoroethylene (PTFE) - silicone rubber or butyl rubber pad and aluminum cap. Impurities that would disturb the measurement of methanol shall not be generated in the pad.

6.4 Rolling and de-capping tools

Used to seal and open headspace bottles.

6.5 Perfluoroalkoxy resin (PFA) bottle

6.6 Electronic Balance

The minimum division value is 0.0001g.

7 Test

7.1 Reference conditions for instrument operation

7.1.1 Reference conditions for gas chromatograph operation

a) Chromatographic column type: polar capillary chromatographic column suitable for separating methanol in the developer;

b) Carrier gas type: high-purity of nitrogen or helium;

c) Carrier gas flowrate: 1.5mL/min;

d) Detector type: hydrogen flame ionization detector;

e) Column temperature: 85°C;

f) Sampler temperature: 150°C;

g) Detector temperature: 300°C.

9 Detection Limit of the Method

Prepare the developer solution and developer solution quantitatively added 20mg/kg methanol standard solution; adjust the instrument to the best working state; measure the methanol content in the developer solution with/without adding methanol standard solution; meanwhile, continuously measure at least for ten times.

The detection limit is calculated by "DL", the value is expressed by "mg/kg", and calculated according to Formula (1):

Where:

C - The value of the concentration of methanol standard solution added to the developer, in (mg/kg) [c = 20];

S - The standard deviation of the peak height or peak area of methanol in the developer solution without adding the methanol standard solution;

S1 - The average peak height or peak area of methanol in the developer solution with adding the methanol standard solution;

S0 - The average peak height or average area of methanol in the developer solution without adding the methanol standard solution;

The standard deviation of the peak height or peak area of methanol in developer solution without adding the methanol standard solution, expressed in terms of “s”, and calculated by Formula (2):

Where:

xi – peak height or peak area of methanol in the developer with adding the methanol standard solution;

– average peak height or peak area of methanol in the developer without adding the methanol standard solution;

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.

Referenced standards

How to Download SJ/T 11141-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
9 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

SJ/T 11141-2017

$80.00