Valid

GB/T 6022-2008Butadiene for industrial use - Determination of oxygen in gaseous phase above liquid butadiene (English PDF)

工业用丁二烯液上气相中氧的测定

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 6022-2008 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

June 19, 2008

Implementation date

February 1, 2009

Scope

GB/T 6022-2008 is the English-translated version of 工业用丁二烯液上气相中氧的测定.

GB/T 6022-2008 is the Chinese standard "Butadiene for industrial use - Determination of oxygen in gaseous phase above liquid butadiene".

Its scope clause reads: standard specifies the determination of industrial liquid butadiene gas phase oxygen content by gas chromatography and thin film covering the battery electrochemistry, gas Determination of the range of 100mL/m3 ~ 5000mL/m3, covered with a thin film battery with electrochemical measurement range of 1mL/m3 ~ 5000mL/m3.

This standard does not explain all of the safety issues associated with use. Therefore, the user has the responsibility to take appropriate safety and health measures Facilities, to ensure compliance with the provisions of the relevant national regulations. Its clauses include gas chromatography.

Found what you need?

Document preview — GB/T 6022-2008

National Standard of the People's Republic of China

ICS
71.080.10
Classification
G 15
Replacing
GB/T 6022-1999

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Gas Chromatography
  • 3.1 Summary of Method
  • 3.2 Reagents and materials
  • 3.3 instruments and equipment

1 Scope

1.1

standard specifies the determination of industrial liquid butadiene gas phase oxygen content by gas chromatography and thin film covering the battery electrochemistry, gas

Determination of the range of 100mL/m3 ~ 5000mL/m3, covered with a thin film battery with electrochemical measurement range of 1mL/m3 ~

5000mL/m3.

1.2

This standard does not explain all of the safety issues associated with use. Therefore, the user has the responsibility to take appropriate safety and health measures

Facilities, to ensure compliance with the provisions of the relevant national regulations.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent

Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research

You can use the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.

GB/T 3723 Sampling of chemical products for industrial use General Safety (GB/T 3723-1999, idt ISO 3165. 1976)

GB/T 6681 General rules for sampling gaseous chemical products

GB/T 8170 numerical rounding rules

3 Gas Chromatography

3.1 Summary of Method

Gas sample through the sampling device into the chromatograph, and a carrier gas into the pre-column, the hydrocarbon components are pre-column adsorption, pre-cleaning

Separation column, the hydrocarbon components vented. Remaining separated components into the separation column, a detector with a thermal conductivity detector. Because oxygen at ambient temperature and in argon

Separation column is not isolated, and therefore the use of argon as a carrier gas, argon in the sample is not generated in response to the thermal conductivity cell. Oxygen peaks obtained surface

Compared with the product of the oxygen peak area obtained from the standard sample, thereby determining the oxygen content in the sample.

3.2 Reagents and materials

3.2.1 Carrier gas

Argon. purity of not less than 99.99% (volume fraction), the oxygen content of not more than 0.002% (volume fraction), free of organic impurities, water and Second

Carbon monoxide.

3.2.2 Preparation of standard sample gas

Nitrogen or argon. purity not less than 99.999% (volume fraction), an oxygen content of not more than 2mL/m3.

Oxygen. purity of not less than 99.99% (volume fraction).

3.2.3 Standard Series Gas Oxygen

The oxygen content was 50mL/m3 ~ 5000mL/m3, emboldened as nitrogen or argon (3.2.2).

3.2.4 stationary phase

Activated carbon (chromatography). diameter of 0.17mm ~ 0.25mm (60 mesh to 80 mesh);

5A molecular sieve (chromatography). diameter of 0.17mm ~ 0.25mm (60 mesh to 80 mesh).

3.3 instruments and equipment

3.3.1 Gas chromatograph

a quantitative gas injection device, cleaning device and a thermal conductivity detector gas chromatograph, the instrument of this standard to

Produces a given peak operating conditions is high, at least two times greater than the noise of the instrument.

3.3.2 Quantitative tubes

1mL or 5mL.

3.3.3 pre-separation column

Stationary phase. activated carbon (3.2.4);

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 6022

EditionTitleRevisionStatus
GB/T 6022-2008Butadiene for industrial use - Determination of oxygen in gaseous phase above liquid butadienecurrent editionCurrent
GB/T 6022-1999Butadiene for industrial use - Determination of oxygen in gaseous phase above liquid butadieneprevious editionSuperseded

This page sells the current edition, GB/T 6022-2008. Earlier editions are listed for reference only.

How to Download GB/T 6022-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 6022-2008

$35.00