Scope
QC/T 1122-2019 is the English-translated version of 汽车发动机用电动水泵技术条件.
QC/T 1122-2019 covers electric water pumps for vehicle engines, specifying requirements, test methods, inspection items and packaging and transport conditions. It applies to pumps with a 12 V supply; other supply voltages may use it as a reference.
Clause 4 requires surfaces free of defects, colour difference, deformation and cracks, sets the starting and normal operating voltage at 12 V plus or minus 4 V, and gives a recommended operating temperature range of -40 degrees C to 125 degrees C. Electrical and climatic behaviour is graded against GB/T 28046.1-2011: reverse voltage must reach at least level C, and temperature gradient, cold water shock, damp heat cycling and salt spray level A. Protection is IP 6K 9K through GB/T 30038.
Durability calls for a general endurance test of at least 2000 h with performance drift under 5 percent, a start-stop test of 345000 cycles with 2 s running and 3 s stalling stages, high temperature working endurance of 500 h in a chamber at 125 degrees C with coolant at 90 degrees C plus or minus 2 degrees C, low temperature working endurance of 500 h in a chamber at -40 degrees C, and 24 hours of idling at 12 V. Vibration runs in X, Y and Z: the resonant frequency between 10 Hz and 200 Hz is found with a 1 g sweep and driven at 20 g, with swept vibration of 8 hours per direction.
Immunity uses bulk current injection from 1 MHz to 400 MHz and the free field method from 200 MHz to 2.5 GHz and 2.7 GHz to 3.2 GHz.
Found what you need?
Document preview — QC/T 1122-2019
National Standard of the People's Republic of China
Issued by: Ministry of Industry and Information Technology of the People's Republic of China
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Technical requirements
- 5 Test method
1 Scope
This standard specifies the technical requirements, test methods, inspection items, technical conditions for packaging and transportation of electric water pumps for automobile engines.
This standard applies to electric water pumps for vehicle engines, which have a power supply voltage of 12 V. The electric water pumps for vehicle engines, which have other power supply voltages, can refer to this standard.
2 Normative references
The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) is applicable to this standard.
GB/T 2423.18-2012 Environmental testing - Part 2: Test methods - Test Kb: Salt mist, cyclic (sodium chloride solution)
GB/T 2828.1 Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection
GB/T 17619 Limits and methods of testing for immunity of electrical / electronic sub-assemblies in vehicles to electromagnetic radiation
GB/T 18655-2018 Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers
GB/T 19951 Road vehicles - Disturbances test methods for electrical/electronic component from electrostatic discharge
GB/T 21437.2 Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
GB/T 21437.3 Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
GB/T 28046.1-2011 Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 1: General
GB/T 28046.2-2011 Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
GB/T 28046.4-2011 Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 4: Climatic loads
GB/T 30038 Road vehicles - Degrees of protection (IP-code) - Protection of electrical equipment against foreign objects, water and access
JB/T 8126.2-2010 Internal combustion engines - Cooling water pumps - Part 2: Test method
3 Terms and definitions
Terms and definitions, as defined in referenced documents in this document, as well as the following terms and definitions, apply to this document.
3.1 Rated condition of electric water pump
The operating conditions of the electric water pump, under the voltage, rated flow, head conditions, which are specified in the technical documents.
4 Technical requirements
4.1 General technical requirements
4.1.1 Electric water pumps shall comply with the provisions of this standard. It shall be manufactured according to the drawings and technical documents, which are approved by the prescribed procedures.
4.1.2 The surface of the electric water pump shall have no defects, obvious color difference, deformation, cracks; the sealing surface shall have no scratches; the chamfers of the sealing ring groove shall be smooth AND shall be free from flash.
4.1.3 The starting and normal operating voltage range of the electric water pump is 12 V ± 4 V.
4.1.4 The recommended operating temperature range of the electric water pump is -40 °C ~ 125 °C, OR meet the requirements of relevant technical conditions.
4.5.6 Reverse voltage
Carry out the test according to 5.5.6. The reverse voltage performance of the electric water pump shall at least reach the level C, which is defined in GB/T 28046.1-2011.
4.6 Environmental adaptability
4.6.1 Temperature gradient
Carry out the test according to 5.6.1. The temperature gradient performance of the electric water pump shall reach the level A, which is defined in GB/T 28046.1-2011.
4.6.2 Cold water shock
Conduct the test according to 5.6.2. The cold water shock performance of the electric water pump shall reach the level A, which is defined in GB/T 28046.1-2011. In addition:
a) After the test, it shall meet the sealing performance requirements in 4.4;
b) Visual inspection after the test, there shall be no visible deformation and cracks;
c) After the test, there shall be no sticking when turning the rotor of the electric water pump.
4.6.3 Damp heat cycle
Carry out the test according to 5.6.3. The damp heat cycle performance of the electric water pump shall reach the level A, which is defined in GB/T 28046.1-2011.
4.7 Electromagnetic compatibility
4.7.1 Electromagnetic immunity
Carry out the test according to 5.7.1. The test results shall meet the requirements of relevant technical documents.
4.7.2 Electromagnetic disturbance
Carry out the test according to 5.7.2. The test result shall meet the requirements of relevant technical documents.
4.8 Reliability and durability
4.8.1 General durability
Carry out the test according to 5.8.1. The test time shall be at least 2000 h. The electric water pump shall meet the following requirements:
a) The performance before and after the test shall meet the requirements of 4.2. During the test and re-inspection after the test, the performance difference from that before the test shall not exceed 5%; the sealing performance shall meet the requirements of 4.4;
b) Check the appearance after the test; there shall be no deformation, crack, leakage;
c) After the performance re-inspection, disassemble and measure the wear of the electric water pump's impeller, shaft, retaining ring; each wear shall meet the requirements of the technical documents.
4.8.2 Start-stop durability
The test shall be carried out according to 5.8.2. The electric water pump shall meet the following requirements:
a) Perform performance re-inspection after the test, which shall meet the requirements of 4.2;
b) It can be started normally during and after the test. The variation of the start-up time shall not exceed the requirements of the technical documents.
4.8.3 Corrosion resistance
Carry out the test according to 5.8.3. After the test, the electric water pump shall meet the following requirements:
a) The performance and tightness re-inspection shall meet the requirements of 4.2 and 4.4;
b) The structure in contact with the cooling liquid shall have no wear and corrosion beyond the relevant technical requirements.
4.8.4 Thermal shock
Carry out the test according to 5.8.4. After the test, the electric water pump shall meet the following requirements:
a) Carry out performance and tightness re-inspection, which shall meet the requirements of 4.2 and 4.4;
b) During visual inspection, it shall show no damage, visible deformation, or cracks.
4.8.5 Waterproof and dustproof
Waterproof and dustproof shall meet the requirements of IP 6K 9K. It implements the relevant requirements of GB/T 30038.
4.8.11 Salt spray test
Carry out the test according to 5.8.10. The electric water pump shall meet the following requirements:
a) The performance and tightness re-inspection after the test shall meet the requirements of 4.2 and 4.4;
b) The functional condition reaches the level A, which is defined in GB/T 28046.1-2011;
c) During visual inspection, the corrosion condition of each component and marking shall not exceed the requirements of relevant technical documents.
4.8.12 High temperature working durability
Carry out the test according to 5.8.11. The electric water pump shall meet the following requirements:
a) The performance and tightness re-inspection after the test shall meet the requirements of 4.2 and 4.4;
b) During and after the test, there shall be no abnormalities in starting and running;
c) During visual inspection, the pump body and impeller shall be free from leakage, visible cracks, deformation;
d) Disassemble and measure the wear of the electric water pump's impeller, shaft, retaining ring; each wear shall meet the requirements of relevant technical documents.
4.8.13 Low temperature working durability
Carry out the test according to 5.8.12. The electric water pump shall meet the following requirements:
a) The performance and tightness re-inspection after the test shall meet the requirements of 4.2 and 4.4;
b) During and after the test, there shall be no abnormalities in starting and running;
c) During visual inspection, the pump body and impeller shall be free from leakage, visible cracks, deformation;
d) Disassemble and measure the wear of the electric water pump's impeller, shaft, retaining ring; each wear shall meet the requirements of relevant technical documents.
4.8.14 Idling test
Carry out the test according to 5.8.13. The electric water pump shall meet the following requirements:
a) Perform performance re-inspection after the test; the performance shall meet the requirements of 4.2;
b) During the test, there is no stagnation, sharp and piercing sound, or damage;
c) Disassemble and measure the wear of the electric water pump's impeller, shaft, retaining ring. The wear shall meet the requirements of relevant technical documents.
4.8.15 Vibration durability
Carry out the test according to 5.8.14. The electric water pump shall meet the following requirements:
a) The performance and tightness re-inspection after the test shall meet the requirements of 4.2 and 4.4;
b) During and after the test, there shall be no abnormal start-up and operation failure;
c) During visual inspection, there shall be no leakage, visible deformation, or cracks;
d) There shall be no loosening of fasteners and solder joints.
5 Test method
5.1 Test conditions
5.1.1 Environmental conditions
Unless otherwise specified, the test shall be carried out in an environment, of which the temperature is 23 °C ± 5 °C, relative humidity is 25% ~ 85%, and atmospheric pressure is 86 ~ 106 kPa.
5.1.2 Test device
Unless otherwise specified, the closed test bench shall be assembled, according to the provisions in 6.4 of JB/T 8126.2-2010; the steam pressure inside the closed water tank shall be consistent with the water tank pressure of the automobile engine cooling system.
5.5.2 Overvoltage test method
The test shall be carried out under the rated operating conditions of the electric water pump, according to the provisions in 4.3.1.1.2 of GB/T 28046.2-2011.
5.5.3 Superimposed alternating voltage test method
The test shall be carried out under the rated operating conditions of the electric water pump, according to the provisions in 4.4.2 of GB/T 28046.2-2011.
5.5.4 Test method for ramp down and up of supply voltage
The test shall be carried out under the rated operating conditions of the electric water pump, according to the provisions in 4.5.2 of GB/T 28046.2-2011.
5.5.5 Test method for transient change of supply voltage
The test shall be carried out under the rated operating conditions of the electric water pump, according to the provisions in 4.6.1.2 of GB/T 28046.2-2011.
5.5.6 Reverse voltage test method
The test shall be carried out under the rated operating conditions of the electric water pump, according to the provisions in 4.7.2 of GB/T 28046.2-2011.
5.6 Environmental adaptability test method
5.6.1 Temperature gradient test method
The test shall be carried out under the rated operating conditions of the electric water pump, according to the provisions in 5.2.2 of GB/T 28046.4-2011. Among them, Tmax and Tmin are the upper and lower limits of the ambient temperature, which is specified in 4.1.4 of this document.
5.6.2 Cold water shock test method
The test shall be carried out under the rated working conditions of the electric water pump, according to the provisions in 5.4.2 of GB/T 28046.4-2011.
5.6.3 Damp heat cycle test method
The test shall be carried out under the rated working conditions of the electric water pump, according to the provisions in 5.6.2 of GB/T 28046.4-2011.
5.7 Electromagnetic compatibility test method
5.7.1 Electromagnetic immunity test method
The electromagnetic radiation immunity test shall be carried out according to the large current injection method and the free field method, respectively. The frequency range of the high current injection method is 1 MHz ~ 400 MHz; the frequency range of the free field method is 200 MHz ~ 2.5 GHz and 2.7 GHz ~ 3.2 GHz.
The large current injection method test shall be carried out, according to GB/T 17619; the injection current shall be carried out, according to the requirements of the technical documents;
The free field method test shall be carried out, according to GB/T 17619; the field strength shall be carried out, according to the requirements of the technical documents;
The anti-interference test of electrical transient conduction shall be carried out, according to GB/T 21437.2 and GB/T 21437.3. The pulse type and severity shall be carried out, in accordance with the relevant provisions in the standard or the requirements of relevant technical documents;
The electrostatic discharge performance test shall be carried out, according to GB/T 19951. The test requirements include: powered state contact discharge ±2 kV and ±4 kV, air discharge ±8 kV; powered state contact discharge ±2 kV, ±4 kV, ±8 kV, air discharge ±4 kV, ±8 kV, ±15 kV.
5.7.2 Electromagnetic disturbance test method
It shall be tested, under the rated working conditions of the electric water pump, according to the measurement method of parts and modules in GB/T 18655-2018.
5.8 Reliability and durability test methods
5.8.1 General durability test method
The general durability test shall be carried out, using the test device specified in 5.1.2; the azimuth angle of the electric water pump shall be the same as that of the engine.
Coolant is used as the test medium; the temperature of the medium is controlled at 90 °C ± 2 °C; the ambient temperature is not controlled.
The performance of the sample before the test shall meet the index requirements. The test shall be carried out under the rated working condition of the electric water pump.
5.8.2 Start-stop durability test method
The start-stop test is carried out, under rated working conditions; the medium is coolant; the temperature of the coolant is controlled at 90 °C ± 2 °C. The test cycle process is as shown in Figure 1, including T1, T2, T3. The T1 stage is the start-up stage; the T2 stage is 2 s, the electric water pump is maintained at the rated working condition in this stage; the T3 stage is 3 s, this stage is the stalling stage. A total of 345000 cycles are performed in the test.
5.8.11 High temperature working durability test method
Install the electric water pump on the system, as shown in Figure 3, for the test. The electric water pump is placed in a high-temperature environment chamber, which has a constant temperature of 125 °C. The medium is coolant. The temperature is 90 °C ± 2 °C. The test is carried out for 500 h, under the rated working condition of the electric water pump.
5.8.12 Low temperature working durability test method
Install the electric water pump on the system, as shown in Figure 3, for the test. The electric water pump is placed in a low-temperature environment chamber, which has a constant temperature of -40 °C. The test medium meets the requirements of relevant documents. The test is carried out for 500 h, under the rated working condition of the electric water pump.
5.8.13 Idling test method
The electric water pump is subjected to an idling test, at a rated voltage of 12 V; the test time is 24 hours.
5.8.14 Vibration durability test method
5.8.14.1 Vibration test requirements
The electric water pump is connected according to the system as shown in Figure 3. The electric water pump is fixed on the vibration test bench, according to the requirements of relevant technical documents. The test is carried out under the rated working condition of the electric water pump. The test medium is coolant.
The hose -- between the electric water pump and the water tank -- shall be long enough, to reduce the pulling force, which is caused by vibration.
The vibration durability test items include vibration durability at a fixed frequency and frequency-sweeping vibration durability. Different pumps are used for the test.
5.8.14.2 Fixed-frequency vibration durability test method
Sweep frequency vibration in three directions of X, Y, Z respectively, for the electric water pump. The frequency sweep acceleration is 1 g. Determine the frequency, corresponding to the maximum vibration acceleration of the electric water pump, within the frequency range of 10 Hz ~ 200 Hz. Then vibrate 10^7 times at this frequency, at an acceleration of 20 g.
5.8.14.3 Frequency sweep vibration durability test method
Sweep frequency vibration in three directions of X, Y, Z respectively, for the electric water pump. The relationship between the acceleration and frequency of the vibration cycle can be as shown in Figure 5, to vibrate for 8 hours in each direction.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 25 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2423.18-2012Environmental testing - Part 2: Test methods - Test Kb: Salt mist, cyclic (sodium chloride solution)
- GB/T 2828.1Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection
- GB/T 17619Limits and methods of testing for immunity of electrical/electronic sub-assemblies in vehicles to electromagnetic radiation
- GB/T 18655-2018Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers
- GB/T 19951Road vehicles — Disturbances test methods for electrical/electronic component from electrostatic discharge
- GB/T 21437.2Road vehicles - Test method of electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
Similar standards
How to Download QC/T 1122-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 17619-1998 — Limits and methods of testing for immunity of electrical/electronic sub-assemblies in vehicles to electromagnetic radiation
GB/T 18655-2018 — Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers
GB/T 19951-2019 — Road vehicles — Disturbances test methods for electrical/electronic component from electrostatic discharge
Secure payment via Stripe
Payments accepted
QC/T 1122-2019
$270.00