NB/T 47013.6-2015Nondestructive Testing of Pressure Equipments - Part 6: Eddy Current Testing (English PDF)
承压设备无损检测 第6部分:涡流检测
This is a limited preview
Buy now to download the full PDF (46 pages)
Need quotation for your management?
Get a formal quotation for NB/T 47013.6-2015 in 30 minutes.
Issued by
NEA
Level / Type
Industry · Recommended
Issue date
April 2, 2015
Implementation date
September 1, 2015
Scope
NB/T 47013.6-2015 is the English-translated version of 承压设备无损检测 第6部分:涡流检测.
NB/T 47013.6-2015 is Part 6 of the Chinese NB/T 47013 series, covering eddy current testing of pressure equipment in manufacture and in service.
It addresses surface and near-surface flaws in conductive metal tubular products, parts and welded joints, and the measurement of cover layer thickness on metal substrates by magnetic and eddy current methods.
Separate clauses deal with ferromagnetic and non-ferromagnetic tubes, remote field testing of in-service ferromagnetic heat exchanger tubes, in-service non-ferromagnetic heat exchanger tubes, and probe-coil testing of parts and welds, with rules on reference samples, sensitivity checks every 2 h during continuous testing, and records.
Compared with JB/T 4730.6-2005, which it replaces, it adds weld testing and cover layer thickness measurement and widens the scope. Issued on 2 April 2015, it has applied since 1 September 2015.
Found what you need?
Document preview — NB/T 47013.6-2015
National Standard of the People's Republic of China
- Classification
- H 26
- Replacing
- JB/T 4730.6-2005
Issued by: National Energy Administration of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative References
- 3 Terminologies and Definitions
- 4 General Requirements
- 5 Eddy Current Testing for Ferromagnetic Tubular Products
- 6 Eddy Current Testing for Non-ferromagnetic Metal Tubular Products
- 7 Far Field Eddy Current Testing for Ferromagnetic Heat Exchange Tube In-Service
- 8 Eddy Current Testing for Non-Ferromagnetic Heat Exchange Tube In-Service
- 9 Eddy Current Testing for the Parts of Probe coil
- 10 Eddy Current Testing for Welds with Probe Coil
- 11 Measurement of Cover Layer Thickness
- 12 Evaluation of Testing Results
- 13 Testing Record and Report
- Appendix A (Normative) Reference Sample for Eddy Current Testing over Flaw Characteristics of Ferromagnetic Tubes for Pressure Equipments In-service
- Appendix B (Normative) Type III Reference Sample for Eddy Current Testing over Non-ferromagnetic Tubes for Pressure Equipments In-service
Foreword
This Standard "Nondestructive Testing of Pressure Equipments" (NB/T 47013) comprises the following 13 parts.
- Part 1. General Requirements;
- Part 2. Radiographic Testing;
- Part 3. Ultrasonic Testing;
- Part 4. Magnetic Particle Testing;
- Part 5. Penetrant Testing;
- Part 6. Eddy Current Testing;
- Part 7. Visual Testing;
- Part 8. Leak Testing;
- Part 9. Acoustic Emission Testing;
- Part 10. Ultrasonic Time of Flight Diffraction Technique;
- Part 11. Standard Practice for X-ray Digital Radioscopy;
- Part 12. Magnetic Flux Leakage Testing;
- Part 13. Pulsed Eddy Current Testing.
This Part is Part 6 of NB/T 47013. Eddy Current Testing.
This Part was drafted according to the rules given in "Directives for Standardization - Part 1. Structure and Drafting of Standards" (GB/T 1.1-2009).
This Part supersedes "Nondestructive Testing of Pressure Equipments - Part 6. Eddy Current Testing" (JB/T 4730.6-2005); compared with JB/T 4730.6-2005, this Part has the following main technical changes.
- the content of eddy current testing for spare parts of probe coil was added;
- the content of eddy current testing for weld of probe coil was added;
- the content of measurement of cover layer thickness was added;
- the testing content of eddy current thickness measurement was added;
- the scope of eddy current testing was extended.
1 Scope
1.1 This Part of NB/T 47013 specifies the requirements for the eddy current testing methods and quality classification of pressure equipments.
1.2 This Part is applicable to the eddy current testing for the surface and near surface flaws of metallic tubular products, spare parts and welded joints having electric conductivity used for the pressure equipments in-fabrication and in-service, and is also applicable to the measurement of surface cover layer thickness of metallic substrate with magnetic method and eddy current method. 1.3 The eddy current testing for the supporting members and structural members relevant to pressure equipments may also be made reference to this Part.
2 Normative References
The following documents for the application of this document are essential. Any dated reference, just dated edition applies to this document. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 5126 Eddy Current Inspection Method for Cold Drawn Thin Wall Tubes of Aluminum and Aluminum Alloy
GB/T 5248 Copper and Copper Alloy - Seamless Tubes - Eddy Current Testing Method
GB/T 7735 Steel Tubes - The Inspection Method on Eddy Current Test
GB/T 12604.6 Non-destructive Testing - Terminology - Terms Used in Eddy Current Testing
GB/T 12969.2 Method of Eddy Current Inspection for Titanium and Titanium Alloy Tubes
GB/T 14480.3 Non-destructive Testing - Equipment for Eddy Current Examination - Part 3. System Characteristics and Verification
NB/T 47013.1 Nondestructive Testing of Pressure Equipments - Part 1. General Requirements
NB/T 47013.3 Nondestructive Testing of Pressure Equipments - Part 3. Ultrasonic Testing
NB/T 47013.4 Nondestructive Testing of Pressure Equipments - Part 4. Magnetic Particle Testing
NB/T 47013.5 Nondestructive Testing of Pressure Equipments - Part 5. Penetrant Testing continuously on whole or local part of the tested workpiece
4 General Requirements
4.2.11 The mechanical transmission mechanism shall ensure the stable relative motion between the tested workpiece and the test coil with specified pattern, and shall not cause any damage to the surface of the tested workpiece.
4.2.12 The recording device shall be able to promptly and correctly record the output signal of testing instrument.
4.2.13 In the following cases, the sensitivity of eddy current testing equipment shall be inspected and reinspected with reference sample.
a) Prior to testing and after testing every time;
b) Suspicion of abnormal state about testing equipment;
c) Change of the specification of tested object;
d) In continuous testing, the inspection and reinspection are conducted once per 2h;
e) Dispute between both contractors, or the inspection regarded as necessary. […]
4.3 Reference sample
4.3.1 The reference sample is mainly used to adjust the testing sensitivity and testing parameters of eddy current testing instrument, to determine the acceptance level and to ensure the accuracy of testing results.
4.3.2 The reference sample shall have the specification, designation, heat treatment condition, surface condition and electromagnetic property same or similar to those of the tested workpiece.
4.3.3 The reference sample surface shall be free from foreign matters and the flaws influencing the calibration.
4.3.4 The artificial flaw processed on reference sample shall be measured by proper method, and shall meet the requirements of relevant standard or technical specification.
4.3.5 The size of artificial flaw on reference sample shall not be interpreted as the smallest detectable flaw size of testing equipment.
4.4 Tested workpiece
4.4.1 The surface of tested workpiece shall be clean, no burrs, and free from powder dust and other contaminants, especially the ferromagnetic particle, that may influence the normal application of eddy current testing; otherwise, all of foreign materials shall be perfectly removed, and the surface of tested workpiece shall not be damaged in the removing process.
4.4.2 The parameters of the tested workpiece such as surface roughness shall meet the requirements of relevant product technical specification.
4.5 Testing environment
4.5.1 The testing process shall comply with the relevant national and local laws, especially the laws and regulations in relation to accident prevention, electric safety, high-risk industry and environmental protection, and the standard users are liable to obey the laws and regulations relevant to safety.
4.5.2 The temperature and relative humidity at the testing site shall controlled within the allowable range of instrument, equipment and the tested workpiece.
4.5.3 The place nearby testing site shall have no magnetic field, vibration, corrosive gas and other interferences that may influence the normal operation of instrument and equipment. some other characteristics of tested workpiece will influence the testing results.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 46 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 5126Eddy current inspection method for cold drawn thin wall tubes of aluminum and aluminum alloy
- GB/T 5248Electromagnetic (eddy-current) examination of copper and copper alloy seamless tube
- GB/T 7735Automated eddy current testing of seamless and welded (except submerged arc-welded) steel tubes for detection of imperfections
- GB/T 12604.6Non-destructive testing - Terminology - Eddy current testing
- GB/T 12969.2Method of eddy current inspection for titanium and titanium alloy tubes
- GB/T 14480.3Non-destructive testing instruments. Equipment for eddy current examination - Part 3: System characteristics and verification
Cited by
- JB/T 2549-2018Specifications for manufacturing aluminum air separation plants
- NB/T 47007-2018Air-cooled heat exchangers
- JB/T 12592-2016Low-low temperature high-efficiency coal-fired flue gas treatment systems
- NB/T 42056-2015Fundamental technical requirements for inlet valves of small hydraulic turbine
- NB/T 47013.1-2015Nondestructive testing of pressure equipments - Part 1: General requirements
- NB/T 47013.10-2015Nondestructive testing of pressure equipments - Part 10: Ultrasonic time of flight diffraction technique
Similar standards
Editions of NB/T 47013.6
| Edition | Title | Revision | Status |
|---|---|---|---|
| NB/T 47013.6-2015 | Nondestructive Testing of Pressure Equipments - Part 6: Eddy Current Testing | current edition | Current |
| JB/T 4730.6-2005 | Nondestructive Testing of Pressure Equipments - Part 6: Eddy Current Testing | previous edition | Superseded |
This page sells the current edition, NB/T 47013.6-2015. Earlier editions are listed for reference only.
How to Download NB/T 47013.6-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 12604.6-2021 — Non-destructive testing - Terminology - Eddy current testing
GB/T 12969.2-2007 — Method of eddy current inspection for titanium and titanium alloy tubes
GB/T 14480.3-2020 — Non-destructive testing instruments. Equipment for eddy current examination - Part 3: System characteristics and verification
Secure payment via Stripe
Payments accepted
NB/T 47013.6-2015