Scope

NB/T 10306-2019 is the English-translated version of 电缆屏蔽用铜带.

NB/T 10306-2019 sets the Chinese energy industry requirements for copper tape used as the metallic screen of power, electronic, radio frequency, communication and control cables.

It lists the permitted copper grades, tempers and sizes, with a specific composition table for the TUP0.003 grade and the other grades referred to GB/T 5231.

Thickness and width tolerances, edge camber of no more than 1.5 mm/m, burr-free slitting and winding flatness are specified, together with tensile strength, elongation, Vickers hardness for information, electrical properties at 20 °C and surface condition.

Test methods point to GB/T 228.1, GB/T 3048.2 or YS/T 478 and GB/T 26303.3, while batch inspection, sampling to YS/T 668, retest rules, labelling and packaging to GB/T 8888 close the document. Issued on 4 November 2019, it has applied since 1 May 2020.

Found what you need?

Document preview — NB/T 10306-2019

National Standard of the People's Republic of China

ICS
29.060.10
Classification
K 11

Issued by: National Energy Administration of the People's Republic of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Requirements
  • 4 Test method
  • 5 Inspection rules
  • 6 Marking, packaging, transportation and storage

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009 "Guidelines for Standardization Work Part 1: Standard Structure and Compilation".

1 Scope

This standard specifies the requirements, test methods, inspection rules, marking, packaging, transportation and storage of copper tape for cable shielding.

This standard applies to copper tape used for shielding power cables, electronic cables, radio frequency cables, communication cables, and control cables.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this document. For undated references, the latest version (including all amendments) applies to this document.

GB/T 228.1-2010 Metallic materials tensile test Part 1: Room temperature test method

GB/T 3048.2 Test methods for electrical properties of wires and cables Part 2: Resistivity test of metallic materials

GB/T 4340.1 Vickers hardness test of metallic materials Part 1: Test method

GB/T 5121 (all parts) Copper and copper alloy chemical analysis methods

GB/T 5231 Processed copper and copper alloy grades and chemical composition

GB/T 8888 Packaging, marking, transportation and storage of heavy non-ferrous metal processing products

GB/T 26303.3 Copper and copper alloy processed material outline dimension test method Part 3: Plate and strip

YS/T 478 Copper and copper alloy conductive eddy current testing method

YS/T 482 Copper and copper alloy analysis method photoelectric emission spectrometry

YS/T 668 Copper and copper alloy physical and chemical testing sampling method

3 Requirements

3.1 Product Classification

3.1.1 Brand, status, specification

The brand, state, and specification of the copper tape used for cable shielding should meet the requirements in Table 1.

Note 1. After negotiation between the supplier and the buyer, other grades, conditions and specifications of copper tape for cable shielding can also be supplied.

Note 2. The length of the product is negotiated between the supplier and the buyer.

3.1.2 Representation

The product mark is expressed in the order of product code, specification, and standard number.

3.2 Chemical composition

The chemical composition of TUP0.003 should meet the requirements of Table 2. The chemical composition of other brands should meet the requirements of the corresponding brands in GB/T 5231.

3.3 Dimensions and allowable deviation

3.3.1 The thickness of the copper tape used for cable shielding and its allowable deviation shall meet the requirements of Table 3.

3.3.2 The width and allowable deviation of the copper tape for cable shielding should meet the requirements of Table 4.

3.3.3 The shape of the copper tape for cable shielding should be flat and straight, and its side curvature should not exceed 1.5 mm/m.

3.3.4 The two sides of the copper tape for cable shielding should be cut neatly without burrs, cracks and curling. The unevenness of any two adjacent layers of the coil should not exceed 1 mm, the unevenness of any two layers, the thickness of 0.2 mm and below does not exceed 1 mm, and the thickness above 0.2 mm does not exceed 2 mm.

3.4 Mechanical properties

The mechanical properties of the copper tape for cable shielding should meet the requirements in Table 5. The results of the Vickers hardness test are for reference only.

Note: For strips with a thickness of less than 0.2 mm, the test results are for reference only or negotiated between the supplier and the buyer.

3.5 Electrical performance

When tested at a temperature of 20 °C, the electrical properties of the copper tape for cable shielding should meet the requirements in Table 6.

3.6 Surface quality

3.6.1 The surface of the copper tape for cable shielding should be smooth, clean, free of oxidation and discoloration, and no defects that may affect the use of it are allowed.

3.6.2 Each strip of strip should be wound tightly and neatly. When there is a core, the size of the core should be negotiated between the supplier and the buyer.

4 Test method

4.1 Chemical composition

The chemical composition analysis of copper tape for cable shielding shall be carried out in accordance with the provisions of GB/T 5121 (all parts) or YS/T 482, and the arbitration analysis method According to the provisions of GB/T 5121 (all parts).

4.2 Dimensions and allowable deviation

The external dimension test of the copper tape for cable shielding shall be carried out in accordance with the regulations of GB/T 26303.3.

4.3 Mechanical properties

The tensile strength and elongation test of the copper tape for cable shielding shall be carried out in accordance with the provisions of GB/T 228.1-2010. The sample number is GB/T P02 in Appendix B of 228.1-2010.The Vickers hardness test is carried out in accordance with the regulations of GB/T 4340.1. It is not recommended to test specimens with a thickness less than 0.2 mm Test the hardness.

4.4 Electrical performance

The electrical performance test of the copper tape for cable shielding shall be carried out in accordance with the provisions of GB/T 3048.2 or YS/T 478. According to GB/T 3048.2 during arbitration The regulations are tested.

4.5 Surface quality

The surface quality of the copper tape for cable shielding should be inspected visually.

5 Inspection rules

5.1 Inspection

The copper tape used for cable shielding shall be inspected according to Table 7. The copper strip shall be inspected and qualified by the manufacturer before leaving the factory. Each batch of products shipped The product quality inspection certificate of the manufacturer shall be attached.

5.2 Sampling

The sampling of copper tape for cable shielding should meet the requirements in Table 8. The sampling method is carried out according to YS/T 668.

5.3 Judgment of inspection results

5.3.1 When the chemical composition is unqualified, the batch of strips shall be deemed unqualified.

5.3.2 When the external dimensions and their allowable deviations and surface quality are unqualified, the coil is judged to be unqualified.

5.3.3 When the test results of tensile strength, elongation, Vickers hardness and electrical properties have unqualified samples, the strips (including the (Including the strip that failed the original inspection), take another double number of samples for repeated testing, and if the repeated test results are all qualified, the whole batch will be judged The strip is qualified. If the repeated test results still have unqualified samples, the batch of strips shall be deemed unqualified, or the supplier shall inspect the strips one by one and deliver the qualified ones.

6 Marking, packaging, transportation and storage

6.1 Logo

The package of copper tape for cable shielding should be attached with a label indicating.

a) The name, trademark and address of the manufacturer;

b) Product name and specifications;

c) Production batch number;

d) Gross weight and net weight (kg);

e) Date of manufacture;

f) Number of this standard;

g) Pictorial signs for precautions during transportation and storage.

6.2 Packaging, transportation and storage

Packaging, transportation, and storage should comply with GB/T 8888.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download NB/T 10306-2019

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

NB/T 10306-2019

$105.00