JB/T 4362-2011Axial flow fans for power stations (English PDF)
电站轴流式通风机
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for JB/T 4362-2011 in 30 minutes.
Issued by
MIIT
Level / Type
Industry · Recommended
Issue date
August 15, 2011
Implementation date
November 1, 2011
Scope
JB/T 4362-2011 is the English-translated version of 电站轴流式通风机.
JB/T 4362-2011 is a recommended Chinese machinery industry standard for the axial flow fans of power stations. It states the technical requirements for these fans, the test methods, the inspection rules and the provisions for marking, packaging and transport, storage and maintenance.
The fans in its scope are the axial blowers, the induced draft fans and the primary air fans of power plant boilers, and it reaches as well the axial fans of power plant desulphurization and denitration installations.
Limits are placed on the working medium temperature of the blowers and of the induced draft fans, and on the dust content of the flue gas. Air is the medium handled by the primary air fan and the blower, flue gas that of the induced draft fan.
Among the standards it quotes are GB/T 1236, GB/T 10178 and JB/T 10213. It replaces JB/T 4362-1999. It carries the Chinese classification J72 and the international classification 23.120.
Found what you need?
Document preview — JB/T 4362-2011
National Standard of the People's Republic of China
- ICS
- 23.120
- Replacing
- JB/T 4362-1999
Issued by: Ministry of Industry and Information Technology of the People's Republic of China
1 Foreword
JB/T 4362-2011 was issued by Ministry of Industry and Information Technology of the People's Republic of China on 15 August 2011 and has been in force since 1 November 2011.
It replaces the earlier edition JB/T 4362-1999.
2 Scope
This standard is a recommended Chinese machinery industry standard for the axial flow fans of power stations. It states the technical requirements for these fans, the test methods, the inspection rules and the provisions for marking, packaging and transport, storage and maintenance. The fans in its scope are the axial blowers, the induced draft fans and the primary air fans of power plant boilers, and it reaches as well the axial fans of power plant desulphurization and denitration installations. Limits are placed on the working medium temperature of the blowers and of the induced draft fans, and on the dust content of the flue gas. Air is the medium handled by the primary air fan and the blower, flue gas that of the induced draft fan. Among the standards it quotes are GB/T 1236, GB/T 10178 and JB/T 10213. It replaces JB/T 4362-1999. It carries the Chinese classification J72 and the international classification 23.120.
3 Normative references
JB/T 4362-2011 cites the following standards, which apply in full or in part through the references made to them in its clauses.
GB/T 1236
GB/T 2888
GB/T 10178
GB/T 13306
JB/T 6444
JB/T 6886
JB/T 6887
JB/T 6888
JB/T 8689
JB/T 8690
JB/T 9101
JB/T 10213
4 About this standard
Issued by: Ministry of Industry and Information Technology of the People's Republic of China
English translation: about 15 pages
5 Related standards
Other editions:
JB/T 4362-1999 (earlier edition)
6 Classification and status
International classification (ICS): 23.120
Chinese Standard Classification (CCS): J 72
Prefix JB/T: recommended standard.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1236Industrial fan -- Performance testing using standardized airways
- GB/T 2888Methods of noise measurement for fans blowers compressors and roots blowers
- GB/T 10178Industrial fans -- Performance testing in situ
- GB/T 13306Plates
- JB/T 6444General technical requirements for packaging of fans
- JB/T 6886Fans - Technical requirements for painting
Cited by
- GB 19761-2020Minimum allowable values of energy efficiency and energy efficiency grades for fan
- DL/T 468-2019Guide on type selection and application for power boiler fans
- JB/T 10963-2010Special equipment for wet flue gas desulfurization - Booster fans
- DL 468-1992Guide on type selection and application for power boiler fans
Similar standards
Editions of JB/T 4362
| Edition | Title | Revision | Status |
|---|---|---|---|
| JB/T 4362-2011 | Axial flow fans for power stations | current edition | Current |
| JB/T 4362-1999 | Axial flow fans for power stations | previous edition | Superseded |
This page sells the current edition, JB/T 4362-2011. Earlier editions are listed for reference only.
How to Download JB/T 4362-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10178-1988 — Site testing of fans
GB/T 10178-2006 — Industrial fans -- Performance testing in situ
GB/T 1236-2000 — Industrial fans. Performance testing using standardized airways
Secure payment via Stripe
Payments accepted
JB/T 4362-2011
$135.00