Scope
JB/T 3019-1999 is the English-translated version of 户内、户外防爆防腐低压电器.
JB/T 3019-1999 is the Chinese standard "Indoor and outdoor explosion-proof and corrosion-resistant low-voltage apparatus".
Its scope clause reads: This standard specifies the requirements, test methods, inspection rules, marking, operating instructions, packaging, transportation and storage of indoor and outdoor explosion-proof and corrosion-proof low-voltage apparatus (hereinafter referred to as apparatus).
This standard is applicable to apparatus used in indoor and outdoor explosive hazardous locations with explosive gas mixture and corrosive medium. This standard is not applicable to apparatus used in explosive hazardous locations with explosive dust. Its clauses include symbols; product classification.
Found what you need?
Document preview — JB/T 3019-1999
National Standard of the People's Republic of China
- Replacing
- JB 3019-1981
Issued by: Ministry of Industry and Information Technology of the People's Republic of China
Contents
- Foreword i
- 1 Scope
- 2 Normative references
- 3 Symbols
- 4 Product classification
- 5 Requirements
- 6 Test methods
- 7 Inspection rules
- 8 Marking and operating instructions
- 9 Packaging, transportation and storage
1 Scope
This standard specifies the requirements, test methods, inspection rules, marking, operating instructions, packaging, transportation and storage of indoor and outdoor explosion-proof and corrosion-proof low-voltage apparatus (hereinafter referred to as apparatus).
This standard is applicable to apparatus used in indoor and outdoor explosive hazardous locations with explosive gas mixture and corrosive medium.
This standard is not applicable to apparatus used in explosive hazardous locations with explosive dust.
2 Normative references
The following standards contain provision which, through reference in this text, constitute provisions of this standard. At the time of publication, all editions cited are valid. All normative documents are subject to revision, and parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below.
GB 3836.1-1983 Electrical apparatus for explosive atmospheres - General requirements
GB 3836.2-1983 Electrical apparatus for explosive atmospheres - Flameproof electrical apparatus d
GB 3836.3-1983 Electrical apparatus for explosive atmospheres - Increased safety electrical apparatus e
GB 3836.4-1983 Electrical apparatus for explosive atmospheres - Intrinsically safe circuits and electrical apparatus i
GB 3836.5-1987 Electrical apparatus for explosive atmospheres - Pressurized electrical apparatus p
GB 3836.6-1987 Electrical apparatus for explosive atmospheres - Oil immersed electrical apparatus o
GB 3836.7-1987 Electrical apparatus for explosive atmospheres - Sand filled electrical apparatus q
GB 3836.8-1987 Electrical apparatus for explosive atmospheres - Non-sparking electrical apparatus n
GB 3836.9-1990 Electrical apparatus for explosive atmospheres - Encapsulated electrical apparatus m
GB 3836.10-1991 Electrical apparatus for explosive atmospheres - Hermetically sealed electrical apparatus h
GB/T 4942.2-1993 Degrees of protection provided by enclosures for low-voltage apparatus (eqv IEC 60947-1: 1988)
GB 9969.1-1998 General principles for preparation of instructions for use of industrial products
GB/T 14048.1-1993 General rules for low-voltage switchgear and controlgear (eqv IEC 60947-1: 1988)
JB/T 834-1999 Environmental technical requirements of low-voltage appliance for tropical use
JB 4324-1986 Test method for chemical gas corrosion of electric products
JB/T 4375-1999 Environmental conditions required by electric products used in outdoor and indoor corrosive locations
3 Symbols
F1 indoor moderate corrosion prevention;
F2 indoor strong corrosion prevention;
W outdoor slight corrosion prevention;
WF1 outdoor moderate corrosion prevention;
WF2 outdoor strong corrosion prevention;
K climate conditions;
C chemically active substance condition;
S mechanically active substance condition;
4 Product classification
The apparatuses are classified into:
a) indoor explosion-proof and moderately corrosion-proof type;
b) indoor explosion-proof and strongly corrosion-proof type;
c) outdoor explosion-proof and slightly corrosion-proof type;
d) outdoor explosion-proof and moderately corrosion-proof type;
e) outdoor explosion-proof and strongly corrosion-proof type.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Cited by
- GB/T 40640.3-2021Informationalized management of chemicals—Part 3: Electronic label application
- FZ/T 99021-2020Numerical control system of batch dyeing machine
- JB/T 11189-2011Electrical apparatus for explosive gas atmospheres - Floodlights
- JB/T 11191-2011Electrical apparatus for explosive gas atmospheres - Fluorescent lamps
Similar standards
Editions of JB/T 3019
| Edition | Title | Revision | Status |
|---|---|---|---|
| JB/T 3019-1999 | Indoor and outdoor explosion-proof and corrosion-resistant low-voltage apparatus | current edition | Current |
| JB 3019-1981 | Indoor and outdoor explosion-proof and corrosion-resistant low-voltage apparatus | previous edition | Superseded |
This page sells the current edition, JB/T 3019-1999. Earlier editions are listed for reference only.
How to Download JB/T 3019-1999
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JB/T 10062-2026 — Probes used in ultrasonic flaw detection - Testing methods for performance
JB/T 10096-2026 — Cases for power semiconductor devices - Selection guidance
JB/T 10097-2026 — Case for power semiconductor device
Secure payment via Stripe
Payments accepted
JB/T 3019-1999
$90.00