HJ/T 373-2007Technical specifications of quality assurance and quality control for monitoring of stationary pollution source(on trial) (English PDF)
Also coversHJT373-2007
This is a limited preview
Buy now to download the full PDF (6 pages)
Need quotation for your management?
Get a formal quotation for HJ/T 373-2007 in 30 minutes.
Issued by
State Environmental Protection Administration Announcement of State Environmental Protection Administration
Level / Type
National · Recommended
Issue date
November 12, 2007
Implementation date
January 1, 2008
Scope
HJ/T 373-2007 (Technical specifications of quality assurance and quality control for monitoring of stationary pollution source(on trial)) is available as an English-translated PDF.
HJ/T 373-2007 is the Chinese standard "Technical specifications of quality assurance and quality control for monitoring of stationary pollution source(on trial)".
Its scope clause reads: This Standard specifies technical requirements for quality assurance and quality control of sampling and testing in the process of manually monitoring and comparison monitoring of waste water discharge and exhaust emission of stationary pollution source.
This Standard applies to the environmental monitoring of waste water discharge and exhaust emission of stationary pollution sources. Its clauses include scope of application; terms and definitions; the technical requirements of quality assurance and quality control for waste.
It was issued by the State Environmental Protection Administration Announcement of State Environmental Protection Administration on 2007-11-12 and took effect on 2008-01-01.
Found what you need?
Document preview — HJ/T 373-2007
National Standard of the People's Republic of China
Issued by: State Environmental Protection Administration Announcement of State Environmental Protection Administration
Contents
- 1 Scope of application...5
- 2 Normative references...5
- 3 Terms and definitions...6
Foreword
In order to implement Environmental Protection Law of the People's Republic of China,
Water Pollution Prevention and Control Law of the People's Republic of China and
Atmospheric Pollution Prevention Law of the People's Republic of China, standardize the
monitoring of pollution source, and ensure the accuracy and reliability of monitoring data
and information, hereby formulate this Standard.
This Standard specifies technical requirements for quality assurance and quality control of
sampling and testing in the process of manually monitoring and comparison monitoring of
waste water discharge and exhaust emission of stationary pollution source.
This Standard is a directive standard.
This Standard is proposed by the Department of Science, Technology and Standards of
State Environmental Protection Administration.
Drafting organizations of this Standard are. China National Environmental Monitoring
Center, and Shenyang Municipal Environmental Monitoring Center.
This Standard was approved by State Environmental Protection Administration on
November 12, 2007.
This Standard was implemented on January 1, 2008.
State Environmental Protection Administration shall be responsible for interpreting this
Standard.
Technical specifications of quality assurance
and qualify control for monitoring of stationary
pollution source (on trial)
1 Scope of application
This Standard specifies technical requirements for quality assurance and quality control of
sampling and testing in the process of manually monitoring and comparison monitoring of
waste water discharge and exhaust emission of stationary pollution source.
This Standard applies to the environmental monitoring of waste water discharge and
exhaust emission of stationary pollution sources.
2 Normative references
The articles contained in the following documents have become part of this Standard
when they are quoted herein. For the undated documents so quoted, all the modifications
or revisions made thereafter shall be applicable to this Standard.
GB 8978-1996 Integrated wastewater discharge standard
GB 12998-91 Water quality-Guidance on sampling techniques
GB 16297-1996 Comprehensive emission standard of air pollutants
GB/T 16157-1996 The determination of particulates and sampling methods of
gaseous pollutants emitted from exhaust gas of stationary source
HJ/T 75-2007 Specifications for continuous emissions monitoring of flue gas emitted
from stationary sources (on trial)
HJ/T 76-2007 Specification and test procedure for continuous emission monitoring
systems of flue gas emitted from stationary sources (on trial)
HJ/T 91-2002 Technical specifications requirements for monitoring of surface water
and waste water
HJ/T 92-2002 Technical requirements for monitoring of total amount of pollutants in
waste water
HJ/T 355-2007 Technical specifications for the operation and assessment of
Wastewater on-line monitoring system (on trial)
HJ/T 356-2007 Technical specifications for validity of wastewater on-line monitoring
data (on trial)
Check-up System of Employment with Certificates for Environmental Monitoring Staff
(Huanfa [2006] No.114)
3 Terms and definitions
For the purpose of this Standard, the following terms and definitions shall apply.
3.1 Quality assurance
The total quality management during the process of environment monitoring includes all
activities and measures to ensure the accuracy and reliability of environmental monitoring
data.
3.2 Quality control
It refers to the operational techniques and activities adopted to meet the quality
requirements of environmental monitoring.
3.3 Comparison monitoring
It refers that in order to verify the accuracy of results of water and gas online automatic
monitor, manual monitoring method and online automatic monitor method are
simultaneously adopted; manual monitoring results are the basis for verifying online
automatic monitoring data. Of which the manual monitoring methods shall use national
standard methods or other currently effective methods.
3.4 Field-laboratory quality control
It refers to the process of synchronous sampling and analysis of quality control samples
and practical samples according to fixed routines. And its quality control results can be
used to determine whether the error of the monitoring results derives from field sampling
or laboratory analysis.
4 The technical requirements of quality assurance and quality control for waste
water monitoring
4.1 Monitoring personnel
When water is deeper than 1 m, sampling shall be conducted at 1/4 depth of water under
surface layer; when depth of water is not more than 1 m, sampling shall be conducted at
1/2 depth of water; the sampling location shall be close to the center of sampling section
and comply with the requirements of 6.3.2 in HJ/T92-2002.
4.4.5 Sampling apparatus
4.4.5.1 Requirements of sampling apparatuses
Sampling apparatuses shall be able to mark the sampling depth, and texture and structure
shall comply with the provisions of GB 12998-91.
4.4.5.2 Cleaning of sampling apparatuses
The sampling a...
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 16297-1996Integrated emission standard of air pollutants
- GB/T 16157-1996Determination of particulates and sampling methods of gaseous pollutants emitted from exhaust gas of stationary source
GB 8978-1996 · GB 12998
Cited by
- NB/T 34036-2020Test method for small biomass boiler
- HJ 91.1-2019Technical specifications for wastewater monitoring
- GB/T 36578-2018Data interface specification for circular economy informatization platform of industrial park
- HJ 57-2017Stationary source emission - Determination of sulfur dioxide - Fixed potential by electrolysis method
- HJ 870-2017Stationary Source Emission - Determination of Carbon Dioxide - Non-Dispersive Infrared Absorption Method
- GB/T 30650-2014Test method of operability of petrolatum tape at low temperature
How to Download HJ/T 373-2007
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 16297-1996 — Integrated emission standard of air pollutants
GB/T 16157-1996 — Determination of particulates and sampling methods of gaseous pollutants emitted from exhaust gas of stationary source
HJ/T 298-2007 — Technical specifications on identification for hazardous waste
Secure payment via Stripe
Payments accepted
HJ/T 373-2007
$120.00