Valid

GB/Z 44813-2024Measurement of fluid flow in closed conduits - Effects of flow pulsations on flow-measurement instruments (English PDF)

封闭管道中流体流量的测量 流体脉动对流量测量仪表的影响

Preview PDF

This is a limited preview

Buy now to download the full PDF (32 pages)

Need quotation for your management?

Get a formal quotation for GB/Z 44813-2024 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

October 26, 2024

Implementation date

October 26, 2024

Scope

GB/Z 44813-2024 is the English-translated version of 封闭管道中流体流量的测量 流体脉动对流量测量仪表的影响.

GB/Z 44813-2024 is a Chinese guiding technical document, not a mandatory standard, and a modified adoption of ISO/TR 3313:2018 that explains how pulsating flow disturbs flow meters in closed pipes.

It defines pulsating flow against steady flow, explains its causes and how it arises in industrial and laboratory installations, and gives ways to detect it and determine its frequency, amplitude and waveform.

It then covers mean flow rate measurement with orifice plates, nozzles and venturi tubes, turbine flowmeters and vortex flowmeters and, where correction is impossible, damping devices or meters less sensitive to pulsation.

It applies to pulsation from a single source upstream or downstream of the primary device, with no flow reversal and no waveform restriction, and to liquids and gases whose density changes little in the measuring section. It was issued on 26 October 2024.

Found what you need?

Document preview — GB/Z 44813-2024

National Standard of the People's Republic of China

ICS
17.120.10
Classification
N 12

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Preface
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Symbols and subscripts
  • 4.1 Symbol
  • 4.2 Subscripts and Superscripts
  • 5 Description and detection of pulsating flow
  • 5.1 Properties of Pipeline Fluids
  • 5.2 The threshold between steady flow and pulsating flow
  • 5.3 Causes of pulsation
  • 5.4 Conditions for pulsating flow in industrial and laboratory flow devices
  • 5.5 Detection of pulsation and determination of frequency, amplitude and waveform
  • 6 Measurement of average flow rate of pulsating flow
  • 6.1 Orifice plates, nozzles and venturi tubes
  • 6.2 Turbine flowmeter
  • 6.3 Vortex Flowmeter
  • Appendix A (Informative) Orifice Plate, Nozzle and Venturi Tube --- Theoretical Analysis
  • A.1 Overview
  • A.2 Derivation of the equation relating flow indication error to pulsation amplitude
  • A.3 Error of flow indication
  • A.4 Quasi-stable time-inertia theory
  • A.5 Predicting Flow Characteristics in Pulsating Flow Using Computational Fluid Dynamics (CFD)
  • Appendix B (Informative) Orifice Plates, Nozzles, and Venturi Tubes - Pulsation Damping Criteria
  • B.1 Introduction
  • B.2 Theoretical Analysis of Sufficient Damping - Subsonic Flow in Throttling Devices
  • Appendix C (Informative) Turbine Flowmeter --- Theoretical Background and Experimental Data
  • C.1 Equations of motion for unsteady flows
  • C.2 Prediction of pulsation error
  • C.3 Development of software diagnostic tools
  • References

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents" Drafting.

This document is modified to adopt ISO /T R3313.2018 "Measurement of fluid flow in closed pipes - Effect of fluid pulsation on flow measuring instruments" The document type was adjusted from ISO 's technical report to my country's national standardization guidance technical document.

The technical differences between this document and ISO /T R3313.2018 and their reasons are as follows.

--- Added the dimensions and SI units of the symbols listed in the symbol table for ease of use (see 4.1).

--- Changed the description of the symbol "d" in the symbol table, because the meaning of "d" in this document also includes the diameter of the bluff body of the turbine flowmeter (See 4.1).

--- Changed the description of "alpha" in the symbol table and "alpha" in the illustrations of Figures A.1 and A.2 because the interpretation of the symbol in this document is not correct.

The "alpha" in the symbol table is consistent with the "alpha" in 6.2.1.2 and Appendix A, and is modified to (qVmin-qVmax)/(2qV).

---Change C to C* and L to L* in formula (27). Because the two symbols in this formula represent capacitance and inductance respectively, they are different from C in the symbol table.

The meaning of "L" is inconsistent with that of "L", so a new symbol is given to distinguish it (see 6.1.4.1.3).

The following editorial changes have been made to this document.

---Change the name of the document to "Measurement of Fluid Flow in Closed Pipes - Effects of Fluid Pulsation on Flow Measuring Instruments";

--- For ease of use, relevant notes are added to the text (see 5.1, A.5);

--- Add the marking and diagram of the flow meter in Figure 1 (see 6.1.4.1.1);

--- Change the symbol "f" in the Strouhal number formula in Appendix A to "fp" (see Appendix A).

1 Scope

This document defines pulsating flow, compares it to steady flow, gives its detection method, and describes the use of orifice plates, nozzles, When measuring fluid in a pipeline using a venturi tube, turbine flowmeter or vortex flowmeter, the influence of pulsating flow on these instruments is discussed in this document.

These types of flow meters are susceptible to pulsating flow.

When correction is not possible, this document also provides methods to avoid or reduce the pulsation effect.

These measures include installing pulsation damping devices and/or selecting flow meters that are not susceptible to pulsation.

This document applies to fluids that generate pulsations from a single source upstream or downstream of the flowmeter primary device.

The flow direction is not reversed, but there is no restriction on the pulsation waveform. This document is applicable to both liquid and gas flows. For gas flows, This can be limited to situations where the density changes within the measuring section of a specific type of flow meter are small.

2 Normative references

This document has no normative references.

3 Terms and Definitions

The following terms and definitions apply to this document.

The URLs for terminology databases used for standardization maintained by ISO and IEC are as follows.

3.1 Steady flow

Flows for which parameters such as velocity, pressure, density and temperature do not vary significantly with time so as to affect the required measurement uncertainty.

3.2 Pulsating flow

The flow rate in the measuring section is a function of time, but when averaged over a sufficiently long period, has a constant average value and is dependent on the pulsation pattern.

The flow of law.

Note 1.Pulsating flow can be divided into two categories.

---Periodic pulsating flow;

---Random pulsating flow.

NOTE 2 For detailed descriptions of steady flow and pulsating flow, see 5.1 and 5.2.

NOTE 3 Unless otherwise specified in this document, the term "pulsating flow" is used to describe periodic pulsating flow.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 32 pages — is available in the English PDF.

Similar standards

How to Download GB/Z 44813-2024

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
32 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/Z 44813-2024

$545.00