Scope
GB/Z 44426.7-2026 is the English-translated version of 躺卧保护组织完整性的辅助器具 第7部分:泡沫的属性、特征和性能.
GB/Z 44426.7-2026 is a guiding technical document, Part 7 of the GB/T 44426 series, dealing with the foam used in assistive products that protect tissue integrity when a person is lying down.
It fixes the vocabulary manufacturers and laboratories use to quantify foam and describes the usual ways of measuring it, covering resilience, hysteresis loss, support and indentation factor, density, hardness, compression set, tensile and tear strength, airflow, fatigue resistance and antimicrobial properties, together with sample requirements, pre-sale documentation and ageing effects.
It addresses block and moulded polyurethane foams, polyether or polyester based, and latex foams made by the Dunlop or Talalay process. Clause 1 leaves out product design, construction and other factors behind clinical performance, and any testing of covers.
It is an identical adoption of ISO/TR 20342-7:2021. It was issued on 28 January 2026.
Found what you need?
Document preview — GB/Z 44426.7-2026
National Standard of the People's Republic of China
- ICS
- 11.180.01
- Classification
- C 45
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- Introduction
- 1.Scope
- 2 Normative References
- 3.Terms and Definitions
- 4.Sample and foam properties
- 4.1 General Provisions
- 4.2 Sample
- 4.3 Pre-sales documents
- 4.4 Composite APTI
- 4.5 Foam density and hardness
- 4.6 Effects of Aging
- 5.Test Methods
- 5.1 General Provisions
- 5.2 Determination of Foam Type
- 5.3 Foam Durability
- 5.4 Foam Hardness
- 5.5 Other Attributes
- Appendix A (Informative) Guidelines for Cross-Reference between Relevant ISO, ASTM, CEN, JIS, and GB Standards
- References
Foreword
This document is a standard or guiding technical document.
This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents". Drafting.
This document is Part 7 of GB/T 44426, "Assistive devices for protecting tissue integrity while lying down." GB/T 44426 has been published as follows.
---Part 1: General Requirements;
---Part 7: Properties, characteristics, and performance of foams;
This document is equivalent to ISO /T R20342-7.2021 "Assistive devices for maintaining tissue integrity while lying down - Part 7: Foam".
The document type of "Sex, Characteristics and Performance" has been changed from an ISO technical report to a guiding technical document in my country.
The following minimal editorial changes have been made to this document.
---Add the corresponding national standards to Appendix A.
Introduction
In different application environments (such as institutional care and home care), recumbent assistive devices (APTIs) that protect tissue integrity while lying down play a crucial role in maintaining body position and preventing... It is highly effective in preventing and treating pressure injuries (pressure ulcers). ISO plans to develop a series of standards to promote quality improvement in APTI (Advanced Pressure Injury Treatment), and these have already been published.
Three standards have been developed. ISO 20342-1, ISO /T R20342-7, and ISO 20342-10.Other standards are still under development.
GB/T 44426, "Assistive Devices for Protecting Tissue Integrity in Reclining Positions," aims to improve the quality and reliability of APTI (Advanced Peripheral Tissue Integrity Devices) and to support their production and testing.
It provides a basis for use and is proposed to consist of 9 parts.
---Part 1: General Requirements. The purpose is to specify recumbent support structures for different application environments (such as institutional care and home care).
General requirements and test methods related to assistive devices for tissue integrity (APTI), for assistive devices that guide lying down to protect tissue integrity.
The APTI (Advanced Pressure Injury Test) plays an important role in the production and testing of pressure-sensitive products, protecting user safety, and preventing and treating pressure injuries.
---Part 2: Microclimate. The purpose is to provide microclimate characteristics such as APTI heat dissipation and water vapor dissipation under specified test conditions. Test method.
---Part 3: Strength and Impact. This section aims to specify the requirements and procedures for APTI strength and impact testing.
---Part 4: Durability. The purpose is to specify the test methods for APTI durability.
---Part 5: Cleaning and Disinfecting Resistance. The purpose is to provide a test to evaluate APTI's resistance to cleaning and disinfection by liquid chemical disinfectants. method.
---Part 6: Horizontal Stiffness. The purpose is to specify the test method for APTI horizontal stiffness.
---Part 7: Properties, Characteristics, and Performance of Foams. The purpose is to provide manufacturers and laboratories with terminology for quantifying foam properties.
And common testing methods.
---Part 8: Pressure Distribution. The purpose is to describe APTI's ability to redistribute pressure and to specify the testing methods for pressure distribution.
Methods, reporting results, and the clinical significance of the results.
---Part 10: Guidelines for Cleaning, Disinfecting, and Caring for Polyurethane Covers. The purpose is to provide guidance on cleaning, disinfecting, and caring for polyurethane covers.
The first "high-specification foam mattresses" were introduced around the 1990s. These combined different types of foam into a multi-layered structure, which... Some of them may be serrated and/or shaped. Compared to the "standard hospital mattress" of the time, it was encased in an elastic cover, providing better comfort.
Regarding its pressure-reducing performance, the "standard hospital mattress" is essentially a single rectangular block of foam encased in a non-elastic outer shell. Over time, this... More advanced and complex multi-layered structures have now become the norm, completely replacing the old products in most modern hospitals.
Depending on different clinical needs and the physical properties of foam mattresses, different properties and values will be utilized to fulfill specific needs.
What matters is the overall performance of the mattress in its environment, not any of its individual components.
When several products are available, understanding the properties of foam can help in understanding and making potential choices. However, based on individual needs assessments... The complete performance of the product is key to ensuring that patients receive the best care.
The foam products mentioned in this document also have additional safety standards, such as fire resistance ratings for components and/or finished products. Legal requirements.
The minimum fire resistance level may vary depending on the application environment, such as residential/medical use.
Manufacturers must explain and substantiate all claims regarding the product's key features, and how these features ensure the product's expected lifespan.
Clinical efficacy within the lifespan. Based on this information, users still have the responsibility to determine whether the recommended foam merely provides adequate performance or far exceeds it. The required performance.
The testing methods mentioned in this document can be used to identify different performance characteristics between products, thereby demonstrating that one type of foam is superior to another.
There are potential advantages. Not all recommended tests for foam performance need to be performed. It should be emphasized that the tests specified in this document... Trial methods do not necessarily simulate actual usage conditions. Therefore, the use of the results data is limited to extensive comparative evaluations between different foam products.
The clinical efficacy of the finished product is the result of a combination of many different factors, many of which are unrelated to the physical properties of the foam.
The type of cover (fabric or other material) used on APTI, and the type of bed frame or support on which the APTI is placed, may affect the finished product.
Overall clinical performance has a significant impact. An unsuitable cover, or replacing the cover with a non-manufacturer-specified product, may affect product efficacy.
Safety, performance, and durability. Continued use of a damaged casing can allow liquid to seep into the foam, affecting its performance and increasing the risk of cross-contamination.
Risk. The overall dimensions of the product also need to be considered, as well as ensuring that there is no risk of clamping between the support and the APTI.
1 Scope
This document defines the terminology used by manufacturers and laboratories to quantify the properties of foam materials and describes commonly used testing methods. This document is intended for use by manufacturers and laboratories.
Users or buyers of these products provide information that enables them to make an informed assessment of the correlation between the physical characteristics of the various products offered. Evaluate.
This document provides the following information regarding latex foam testing.
---Polyurethane foam produced by block (bulk foam) or molded foam processes - typically polyether (polyether-type polyurethane foam) or poly Ester-based (polyester-type polyurethane foam);
---Latex foam produced by the Dunlop or Tarara process.
The physical properties covered in this document include.
a) Rebound performance;
b) Lag loss;
c) Support/indentation coefficient;
d) Density;
e) Hardness;
f) Compression set;
g) Tensile strength;
h) Tear strength;
i) Airflow/Air permeability;
j) Fatigue resistance;
k) Antimicrobial properties.
Note: The test methods described in this document may not necessarily simulate actual use conditions. Therefore, the use of the results data is limited to extensive testing on different foam products. Comparative evaluation.
This document only describes the characteristics and properties of foam materials used in assistive devices for protecting tissue integrity (APTI), and does not describe the products themselves.
Design, construction methods, or other factors related to the final clinical efficacy.
This document does not describe any test methods for the physical properties of the outer casing or the effect of the outer casing on the physical properties of the foam material.
2 Normative references
The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are not included.
For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies. This document.
Note: GB/T 44426.1-2024 Assistive devices for maintaining tissue integrity while lying down - Part 1: General requirements (ISO 20342-1:2022, MOD)
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.
Similar standards
How to Download GB/Z 44426.7-2026
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/Z 102.17-2026 — Semiconductor devices - Discrete devices - Part 17: Magnetic and capacitive coupler for basic and reinforced insulation
GB/Z 103-2026 — Health informatics - The architecture of internet healthcare service network
GB/Z 108-2026 — Health informatics - Internet healthcare service pattern
GB/Z 44426.7-2026
$300.00