GB/Z 26213-2010Calculations for interior lighting basic method (English PDF)
室内照明计算基本方法
This is a limited preview
Buy now to download the full PDF (48 pages)
Need quotation for your management?
Get a formal quotation for GB/Z 26213-2010 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
January 14, 2011
Implementation date
January 14, 2011
Scope
GB/Z 26213-2010 is the English-translated version of 室内照明计算基本方法.
GB/Z 26213-2010 is the Chinese standard "Calculations for interior lighting basic method". Its scope clause reads: This guideline technical document proposes a basic method, one that does not rely on the standard lamp light distribution and is not limited to the luminaire General installation method.
This method is called "basic method" because it serves as a basis for applying the method.
This method can be applied in the following areas. a) The indoor environment is a rectangular parallelepiped; b) The work surface can be assumed to be the plane of a material and is considered to be an interior surface of the house; c) The surface of the room is uniformly reflected and complies with Lambert's law, with a ceiling reflectance of R1 and a mid-fin reflectivity of R2 (defined as the ceiling The part of the vertical plane between the plate and the lamp), the reflectance of the wall is R3 (defined as the vertical surface between the lamp plane and the working plane) R4 is the working surface reflectance 1); d) There is no significant change in the direct flux of the working surface if the luminaires are rotated around their vertical axis 2). Its clauses include general; f4 direct exposure to luminous flux.
Found what you need?
Document preview — GB/Z 26213-2010
National Standard of the People's Republic of China
- ICS
- 91.160.10
- Classification
- K 70
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 General
- 2 F4 direct exposure flux Flux
- 3 reflect each other
- 4 Calculation of illumination
- 5 Luminous flux calculation
- Appendix A (informative) computer using the formula
- Appendix B (informative) mathematical background
1 General
This guideline technical document proposes a basic method, one that does not rely on the standard lamp light distribution and is not limited to the luminaire
General installation method.
This method is called "basic method" because it serves as a basis for applying the method.
This method can be applied in the following areas.
a) The indoor environment is a rectangular parallelepiped;
b) The work surface can be assumed to be the plane of a material and is considered to be an interior surface of the house;
c) The surface of the room is uniformly reflected and complies with Lambert's law, with a ceiling reflectance of R1 and a mid-fin reflectivity of R2 (defined as the ceiling
The part of the vertical plane between the plate and the lamp), the reflectance of the wall is R3 (defined as the vertical surface between the lamp plane and the working plane)
R4 is the working surface reflectance 1);
d) There is no significant change in the direct flux of the working surface if the luminaires are rotated around their vertical axis 2).
2 F4 direct exposure to luminous flux
To define the direct exposure flux of a work surface, it is assumed that the light emitted by the luminaire is conical with an axis coincident with the vertical axis of the luminaire,
And can be expressed as a cone-shaped fourth-order polynomial cube corner function without constants.
In the polynomial, the actual integral with the four solid angle regions pi/2, pi, 3pi/2, 2pi3) is given by selecting the specific coefficients belonging to different luminaires
Luminous flux the same exact value. In the proposed method, the luminous fluxes FC1, FC2, FC3 and FC44 of these four regions describe the
Distribution, F is the total light output of the lamp (upper light and lower light).
Under these conditions, the symmetry point light source flux (Fu) obtained from the rectangle vertically above a certain corner of the rectangle is the luminous flux FC1,
FC2, FC3, FC4 linear function.
The weighting factors GM1, GM2, GM3, GM45) are the ratio function X/H of the length of each side of the rectangle to the height of the rectangle from the luminaire
Y/H (see Figure 1). These factors are multiplied by 1000 and are given in Tables I.1 through I.6.
1) The international lighting glossary uses rho to represent the reflectance.
2) This is the case with most fluorescent lamps and lanterns. In the case of obvious asymmetry, a special calculation method should be used. This method is additional
The report states.
The definition of symmetrical luminaire given by international lighting vocabulary is slightly different. "Illumination with symmetrical light intensity distribution".
3) The half-width limits of the four regions are respectively .41 °, 4 °; 60 °, 0 °; 75 °, 5 °; 90 °, 0 °.
4) FC. Cumulative flux.
5) GM. Geometric multiplier.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 48 pages — is available in the English PDF.
Similar standards
How to Download GB/Z 26213-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/Z 102.17-2026 — Semiconductor devices - Discrete devices - Part 17: Magnetic and capacitive coupler for basic and reinforced insulation
GB/Z 103-2026 — Health informatics - The architecture of internet healthcare service network
GB/Z 108-2026 — Health informatics - Internet healthcare service pattern
GB/Z 26213-2010
$650.00