Valid

GB/Z 26212-2010Discomfort glare in interior lighting (English PDF)

室内照明不舒适眩光

Preview PDF

This is a limited preview

Buy now to download the full PDF (31 pages)

Need quotation for your management?

Get a formal quotation for GB/Z 26212-2010 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

January 14, 2011

Implementation date

January 14, 2011

Scope

GB/Z 26212-2010 is the English-translated version of 室内照明不舒适眩光.

Identical to CIE 117-1995, GB/Z 26212-2010 presents the Unified Glare Rating (UGR) as the CIE system for assessing discomfort glare from interior lighting.

It traces how the formula was derived from the CIE Glare Index and then explains each of its terms: background luminance, luminaire luminance, the solid angle subtended at the observer's eye and the Guth position index, together with the properties and limitations of UGR.

Two derived methods are given for simpler use, the tabular method and the UGR curve method, with informative annexes on UGR tables, UGR curves, the photometric data required and a worked lighting design example.

Luminaire manufacturers can use the derived methods to publish glare data on their luminaire data sheets. It was issued on 14 January 2011.

Found what you need?

Document preview — GB/Z 26212-2010

National Standard of the People's Republic of China

ICS
91.160.10
Classification
K 70

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Preface
  • Introduction
  • 1 General and scope
  • 2 uncomfortable glare
  • 3 formula export
  • 4 Uniform Glare Level (UGR) Formula
  • 4.1 Formula
  • 4.2 background brightness
  • 4.3 lamp brightness
  • 4.4 Stereoscopic angle of the observer's eye
  • 4.5 Location Index
  • 5 The nature of the UGR formula
  • 6 UGR formula of the limitations
  • 7 Export Method
  • 7.1 Exported List Method
  • 7.2 Export UGR Curve Method
  • Appendix A (informative) unified glare rating form
  • A.1 Introduction
  • A.2 Form standard and reference parameters set
  • A.3 Calculation of UGR tables
  • A.4 Application of UGR forms
  • Appendix B (informative) UGR curve
  • B.1 UGR curve
  • B.2 Derivation of UGR curves
  • B.3 UGR curve of the use
  • Appendix C (informative) lighting data
  • C.1 Introduction
  • C.2 Light intensity distribution table
  • C.3 lamp shape and size data
  • Appendix D (Informative) Example
  • D.1 Lighting Design Figure
  • D.2 Average illuminance calculation
  • D.3 Calculation of UGR values
  • D.4 Comparison of calculated values
  • References

Foreword

This guidance document is equivalent to CIE117-1995 "Inconsistent glare for indoor lighting" (English version). This Guidance Document is equivalent to CIE 117-1995.

For ease of use, the following technical editorial changes have been made in this Guidance Document.

a) Use decimal '.' instead of ',' as a decimal point;

b) Delete the preface of CIE 117-1995.

Appendix A, Appendix B, Appendix C and Appendix D of this guidance document are informative appendices.

Introduction

The Uniform Glare Rank (UGR) formula described in this guidance document contains features of the Einhorn and Hopkinson formulas Combined with the Guth Location Index. It can be considered that this formula contains the main formula precision in terms of usability and glare prediction accuracy China part. The formula states that the glare index is influenced by the observer's position and line of sight.

In the appendix, this guidance document also describes a list method that uses baseline values and standard conditions to allow the generation of a simple Table, similar to the utilization factor table used in the fixture data page.

A rough estimate of discomfort glare is given by the brightness limit curve (UGR curve) method. This is also given in the appendix How to draw and use.

1 General and scope

CIE 29.2-1986 contains the CIE Glare Index formula and a CIE brightness limit system called the CIE Safety Guard System, Use them to predict uncomfortable glare in your work environment.

Computer-based formulas can be used to predict a space discomfort glare with a specific set of conditions. Brightness limit system is used Simply evaluate the suitability of a lamp for general lighting under a limited number of conditions.

The TC3-13 committee was asked to provide a "real glare evaluation system." This report contains the results of this task. Three glare evaluation methods have been developed.

a) The basic Uniform Glare Rating (UGR) formula;

b) Calculated formulas that can be deduced for simple comparison under different lighting conditions;

c) Derived from the "brightness limit song can help lighting design and lighting designers can guide the general applicability of light" Line Law. " UGR formula is recommended by CIE. Its practical application requires the use of computer software. The two exported methods included in the attachment are In order to provide information that can assist lighting manufacturers in designing aids and publish them as luminaire data pages (derived methods are available in some countries Standard is also used).

2 Uncomfortable glare

Discomfort Glare is defined in CIE 17.4-1987 as follows.

In the case of not necessarily diminishing the visual effects of objects, resulting in uncomfortable glare.

3 Formula of the export

According to a study and practice of uncomfortable glare, the following CIE Glare Index (CGI) was proposed in CIENo. formula.

Ed --- direct light illumination (lx) in the eyes with all light sources; Ei --- indirect illumination in the eyes (lx);

L --- in the direction of the observer eye each luminaire light-emitting part of the brightness (cd · m-2);

omega --- in the observer's eyes each luminaire luminous angle of the solid part; p --- Each fixture of the Goose position index (relative to the line of sight of displacement).

The log throughout this report refers to the base 10 logarithm.

At the time, the formula was considered the best mathematical compromise among different national systems. Use this formula to derive a viable option Comfort glare evaluation system encountered many difficulties in the process, so a number of simplified treatment. All discomfort formulas have the following form.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 31 pages — is available in the English PDF.

Referenced standards

Normative references

CIE 17.4-1987 · CIE 29.2-1986

Similar standards

How to Download GB/Z 26212-2010

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
31 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/Z 26212-2010

$445.00